IMPROVING CONCEPTUAL MODEL OF CRYSTALLINE BASEMENT AQUIFERS USING ELECTRICAL RESISTIVITY AND SEISMIC REFRACTION TOMOGRAPHY

2020 ◽  
Author(s):  
Kennedy Doro ◽  
◽  
Michael A. Oladunjoye
2020 ◽  
Author(s):  
remi valois ◽  
Nicole Schafer ◽  
Giulia De Pasquale ◽  
Gonzalo Navarro ◽  
Shelley MacDonell

<p>Rock glaciers play an important hydrological role in the semiarid Andes (SA; 27º-35ºS). They cover about three times the area of uncovered glaciers and they are an important contribution to streamflow when water is needed most, especially during dry years and in the late summer months. Their characteristics such as their extension in depth and their ice content is poorly known. Here, we present a case study of one active rock glacier and periglacial inactive geoform in Estero Derecho (~30˚S), in the upper Elqui River catchment, Chile. Three geophysical methods (ground-penetrating radar and electrical resistivity and seismic refraction tomography) were combined to detect the presence of ice and understand the internal structure of the landform. The results suggest that the combination of electrical resistivity and seismic velocity provide relevant information on ice presence and their geometry. Radargrams shows diffraction linked to boulders presence but some information regarding electromagnetic velocity could be extracted. These results strongly suggest that such landforms contain ice, are therefore important to include in future inventories and should be considered when evaluating the hydrological importance of a particular region.</p><p> </p>


Water ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2835
Author(s):  
Yawar Hussain ◽  
Rogerio Uagoda ◽  
Welitom Borges ◽  
Renato Prado ◽  
Omar Hamza ◽  
...  

Reliable characterization of the karst system is essential for risk assessment where many associated hazards (e.g., cover-collapse dolines and groundwater pollution) can affect natural and built environments, threatening public safety. The use of multiple geophysical approaches may offer an improved way to investigate such cover-collapse sinkholes and aid in geohazard risk assessments. In this paper, covered karst, which has two types of shallow caves (vadose and fluvial) located in Tarimba (Goias, Brazil), was investigated using various geophysical methods to evaluate their efficiency in the delineation of the geometry of sediments filled sinkhole. The methods used for the investigation were Electrical Resistivity Tomography (ERT), Seismic Refraction Survey (SRS), Seismic Refraction Tomography (SRT) and the Very Low Frequency Electromagnetic (VLF-EM) method. The study developed several (2D) sections of the measured physical properties, including P-wave velocity and electrical resistivity, as well as the induced current (because of local bodies). For the analysis and processing of the data obtained from these methods, the following approaches were adopted: ERT inversion using a least-square scheme, Karous-Hjelt filter for VLF-EM data and time-distance curves and Vp cross-sections for the SRS. The refraction data analysis showed three-layered stratigraphy topsoil, claystone and carbonate bedrock, respectively. The findings obtained from ERT (three-layered stratigraphy and sediment-filled doline), as well as VLF-EM (fractured or filled caves as a positive anomaly), were found to be consistent with the actual field conditions. However, the SRS and SRT methods did not show the collapsed material and reached the limited the depth because of shorter profile lengths. The study provides a reasonable basis for the development of an integrated geophysical approach for site characterization of karst systems, particularly the perched tank and collapse doline.


2019 ◽  
Vol 24 (1) ◽  
pp. 27-38
Author(s):  
B. Butchibabu ◽  
Prosanta K. Khan ◽  
P.C. Jha

Geophysical investigations were carried out for evaluation of damage and to assess the possible causes for repeated occurrence of damage at one of the buildings constructed for oil pumping in the northern part of India. Electrical Resistivity Tomography (ERT) and Seismic Refraction Tomography (SRT) techniques were adopted for studying the subsurface of the area around the building with an objective of ascertaining the cause of damage. High resolution imaging was done using both the techniques in this investigation. ERT delineated the presence of low resistivity (2 ohm-m) water filled voids below the structures and mapped different subsurface layers such as sandy soil, clay and sandstone in the study area. SRT revealed P-wave velocity ( V P ) of the subsurface medium in the range of 400–3,400 m/s. Corresponding densities and S-wave velocities ( V S ) were determined based on Gardner's and Castagna's relationships. Subsequently, the V P , V S and the modulus values were used in estimating compressibility of soil and rock strata. Results showed near surface layers were characterized by high compressibility (26.673 × 10 −5 Pa −1 ), decreases with depth. This paper presents the details of the site, techniques used in the investigation and correlation of geophysical results with lithological information, and the subsequent analysis for understanding the distress in the subsurface of the study area.


Sign in / Sign up

Export Citation Format

Share Document