Spectrocoulometry – a new spectro-electrochemical technique

1987 ◽  
Vol 52 (6) ◽  
pp. 1386-1396 ◽  
Author(s):  
Ján Mocák ◽  
Michal Németh ◽  
Mieczyslaw Lapkowski ◽  
Jerzy W. Strojek

A spectrocoulometric macrocell with a direct-view optical probe was designed and constructed, where the optical signal is transferred by light-conducting glass or quartz fibres permitting to work at wavelengths above 410 or 300 nm. The method of measurement on the proposed equipment is described; it was tested in the study of the mechanism and kinetics of oxidation of Fe(bipy)32+ ions (bipy = 2,2'-bipyridyl) with the use of potentiostatic coulometric electrolysis with open-circuit relaxation at a suitable time. The primary product of electrolysis, Fe(bipy)33+, undergoes a follow-up hydrolytic reaction with the formation of a binuclear complex. The rate constant of the reaction of the first order involves the contributions, kBi, from all bases present in solution; the corresponding values for H2O, OH-, bipy, and CH3COO- ions at a ionic strength 0·5 mol dm-3 and 25 °C were determined as kOH = (5·0 ± 0·6) . 105 mol-1 dm3 s-1, kbipy = (1·3 ± 0·2) . 10-1 mol-1 dm3 s-1, kAc = (5·8 ± 1·0) . 10-2 mol-1 dm3 s-1, and kH2O is not significant with respect to experimental errors.

2012 ◽  
Vol 127 (4) ◽  
pp. 3198-3203 ◽  
Author(s):  
Shijie Xiao ◽  
Weiyu Cao ◽  
Bin Wang ◽  
Lianghua Xu ◽  
Biaohua Chen

2015 ◽  
Vol 98 (7) ◽  
pp. 2205-2213 ◽  
Author(s):  
Robert W. Harrison ◽  
William Edward Lee

2012 ◽  
Vol 10 (12) ◽  
pp. 1477-1482 ◽  
Author(s):  
M. Zach Koontz ◽  
Brendan M. Visser ◽  
Pamela L. Kunz

A 36-year-old woman presented to the emergency department with black stools and syncope. Her hemoglobin was 7.0 and her red blood cells were microcytic. Upper endoscopy did not identify a clear source of bleeding, but a bulge in the third portion of the duodenum was noted. A CT scan showed a large extraintestinal mass, and follow-up esophagogastroduodenoscopy/endoscopic ultrasound with biopsy revealed a spindle cell neoplasm, consistent with gastrointestinal stromal tumor (GIST). Because of the size of the lesion and association with the superior mesenteric vein and common bile duct, she was referred to medical oncology for consideration of neoadjuvant imatinib. Neoadjuvant tyrosine kinase inhibitor therapy for GISTs is emerging as a viable treatment strategy for borderline resectable tumors, although the dose, duration, and optimal imaging modalities have not been clearly established. Recent pathologic and radiographic data have provided insight into the mechanism and kinetics of this approach. This case report presents a patient for whom surgery was facilitated using neoadjuvant imatinib.


1989 ◽  
Vol 5 (06) ◽  
pp. 699-704
Author(s):  
Yu Qiquan ◽  
◽  
Jin Yun ◽  
Zhang Fan ◽  
Guo Qinlin ◽  
...  

2003 ◽  
Vol 762 ◽  
Author(s):  
Guozhen Yuea ◽  
Baojie Yan ◽  
Jeffrey Yang ◽  
Kenneth Lord ◽  
Subhendu Guha

AbstractWe have observed a significant light-induced increase in the open-circuit voltage (Voc) of mixed-phase hydrogenated silicon solar cells. In this study, we investigate the kinetics of the light-induced effects. The results show that the cells with different initial Voc have different kinetic behavior. For the cells with a low initial Voc (less than 0.8 V), the increase in Voc is slow and does not saturate for light-soaking time of up to 16 hours. For the cells with medium initial Voc (0.8 ∼ 0.95 V), the Voc increases rapidly and then saturates. Cells with high initial Voc (0.95 ∼ 0.98 V) show an initial increase in Voc, followed bya Voc decrease. All light-soaked cells exhibit a degradation in fill factor. The temperature dependence of the kinetics shows that light soaking at high temperatures causes Voc increase to saturate faster than at low temperatures. The observed results can be explained by our recently proposed two-diode equivalent-circuit model for mixed-phase solar cells.


Sign in / Sign up

Export Citation Format

Share Document