scholarly journals Comparison of the diagnostic value of bone marrow biopsy and bone marrow aspiration in neoplastic disease

1974 ◽  
Vol 27 (9) ◽  
pp. 738-740 ◽  
Author(s):  
J. D. Bearden ◽  
G. A. Ratkin ◽  
C. A. Coltman
2018 ◽  
Vol 7 (4) ◽  
pp. 517-523
Author(s):  
Amit Varma ◽  
◽  
Ashok K. Rajoreya ◽  
Priyanka Kiyawat ◽  
Kamal Malukani ◽  
...  

Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 4544-4544
Author(s):  
Ronan T. Swords ◽  
Kevin R. Kelly ◽  
Devalingam Mahalingam ◽  
Stephen C. Cohen ◽  
Larry J. Miller ◽  
...  

Abstract Abstract 4544 Background The importance of bone marrow aspiration and biopsy in the evaluation of hematopoietic and non-hematopoietic disorders is well established. Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. Aims The first aim of this study was to evaluate the quality of core specimens using the new powered device compared to specimens obtained using the traditional manual technique in a swine model. The second aim was to evaluate the safety and efficacy of the device in patients presenting for outpatient hematology clinic visits. Materials and Methods For the pre-clinical evaluation of the device, three anesthetized pigs were used for the study. The powered device (OnControl, Vidacare Corporation, San Antonio, TX, USA) was comprised of a battery powered driver and needle set. The manual device used was a T-Handle Jamshidi bone marrow biopsy needle (Cardinal Health, Dublin, OH, USA). Core biopsy samples obtained were assessed for length and sample quality and then submitted for analysis to a pathologist blinded to the device used. The clinical evaluation of the device was conducted in accordance with practice guidelines and directions for use. Data collection included insertion success, time from insertion to removal, specimen quality, operator satisfaction with control/function of the device and overall operator satisfaction based on a scoring system (0-5; 0=totally unacceptable, 5=outstanding). Results Twenty six samples were collected from the swine model (19 samples using the powered device and 9 using the manual technique). No cellular artifact or thermal damage was reported in any of the samples obtained. The mean lengths for samples obtained using the powered and manual techniques were respectively 19.4mm±1.6mm and 18.6mm±5.3mm. For the clinical evaluation of the device, 16 patients were recruited from 2 centers. Mean insertion time was 11.25±3.39 seconds and mean time from needle contact with skin to needle removal was 38.5±13.94 seconds. No complications were reported. Five operators rated the overall use of the device as outstanding in 75% of cases. Conclusions In this study, the manual and powered samples were equivalent in specimen quality. The powered device however, captured longer biopsies when compared to the manual technique. In the patients evaluated, the device was easy to use as well as being safe and effective. The mean procedural time was significantly faster than previously reported with a manual technique. A randomized study of the powered device compared to the manual technique is underway. Disclosures: Swords: Vidacare Corporation: Research Funding. Kelly:Vidacare Corporation: Research Funding. Mahalingam:Vidacare Corporation: Research Funding. Cohen:Vidacare Corporation: Membership on an entity's Board of Directors or advisory committees, Research Funding. Miller:Vidacare Corporation: Employment, Equity Ownership. Philbeck:Vidacare Corporation: Employment, Equity Ownership. Brenner:Vidacare Corporation: Consultancy, Research Funding. Giles:Vidacare Corporation: Research Funding.


Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 1529-1529 ◽  
Author(s):  
Ronan Swords ◽  
Javier Anguita ◽  
Russell A. Higgins ◽  
Andrea Yunes ◽  
Michael Naski ◽  
...  

Abstract Abstract 1529 Introduction: The importance of bone marrow aspiration and biopsy in the evaluation of hematopoietic and non-hematopoietic disorders is well established. However, this technique is associated with morbidity and mortality risks.1 Recently, a battery-powered bone marrow biopsy system was developed to allow operators to safely, quickly and efficiently access the marrow space. We previously evaluated this device in swine models and in patients needing routine hematology outpatient evaluation.2 In the current study we compared the powered device to the traditional manual technique by relatively assessing pain scores, procedure times, biopsy capture rates, quality of material retrieved, safety and operator satisfaction. Methods: Two large academic medical centers participated in this trial (San Antonio, TX and Madrid, Spain). The study protocol was approved by each center's institutional review board. Adult patients requiring bone marrow biopsies were considered for the study. Following informed consent, patients were randomized to have procedures using a manual biopsy device (T-handle Jamshidi bone marrow biopsy and aspiration set, Cardinal Health, Dublin, OH) or the Powered device (OnControl 11 gauge/102mm Bone Marrow Biopsy System, Vidacare Corporation, Shavano Park, TX). After infiltration of the skin and medullary bone with local anesthesia, a visual analog scale (VAS) pain score was recorded immediately following skin puncture and once again at the end of the procedure for each patient. Procedure time was measured from skin puncture to core specimen ejection from the needle. Pathologic assessment of 30 randomized samples was carried out. Operator satisfaction with devices was measured on a scale of 0–10, with 10 as the highest rating. Statistics were calculated using t-test and chi-square, with an alpha-level of 0.05. Results: Five operators from 2 sites enrolled 50 patients (Powered, n=25; Manual, n=25). Of those patients, 58% were male and 42% were female; and had a mean age of 56.0±18.0 years. The mean height was 167.5 ± 10.5cm and the mean weight was 78.7 ± 22.7kg. Forty percent were lymphoma patients—the largest diagnostic group. Between patient groups, there were no significant differences in the means for these variables. See Table below for quantitative results, including pathology analysis. For the pathology qualitative analysis, there was no difference between groups for hemorrhage, clot/particle spicules, or smear spicules. Conclusions: Results of this trial suggest that the use of a Powered bone marrow biopsy device significantly reduces needle insertion pain. While not reflected in the results, overall pain may be better tolerated due to the important difference in procedure time. Moreover, the superior size and overall quality of core specimens retrieved by the Powered device provides more material for pathologic evaluation, thereby increasing diagnostic yield and reducing the need for repeat procedures. Cohesiveness of the medullary bone sampled was comparable for both techniques; however, the Powered system was less likely to recover non-hematopoietic tissue (e.g. cortical bone and soft tissue). Artifact was slightly more common with the Powered device (aspiration, hemorrhage and crush) but this did not impact on the diagnostic quality of the sample. No differences in safety data were noted for either technique and operator satisfaction favored the Powered device. 1. Bain BJ. Bone marrow biopsy morbidity and mortality. British Journal of Haematology 2003;121:949-51. 2. Swords RT, Kelly KR, Cohen SC et al. Rotary powered device for bone marrow aspiration and biopsy yields excellent specimens quickly and efficiently. J Clin Pathol 2010;63:562-5. Disclosures: Swords: Vidacare Corporation: Research Funding. Anguita:Vidacare Corporation: Research Funding. Kelly:Vidacare Corporation: Research Funding. Philbeck:Vidacare Corporation: Employment. Miller:Vidacare Corporation: Employment, Equity Ownership. Brenner:Vidacare Corporation: Research Funding.


2018 ◽  
Vol 2 (2) ◽  

Background: Bone marrow aspiration and biopsy is one of the most important diagnostic tools for evaluation of undifferentiated fever. The positivity yield of these samples is highly specific that provides additional evidence for clinical decision making among the undifferentiated febrile cases. With this background we evaluated the bone marrow results of undifferentiated febrile cases for the last five years at B.P. Koirala Institute of Health Sciences, Dharan, Nepal. The objective of the study was to measure the sensitivity of the bone marrow investigations among undifferentiated febrile cohort. Methods: A retrospective study was performed from January 2010 till December 2014 evaluating bone marrow reports. Completed request forms and the histopathological reports of the bone marrow specimens were reviewed. Statistical data was analyzed using SPSS 17 and p-value of <0.05 was considered significant. Results: Over the half decade 319 specimens were collected for bone marrow biopsy out of that 27% were requested for undifferentiated fever. The mean and median age of the biopsy performed patients was 35 and 31 years respectively. Among all biopsy samples 59% was adequate for evaluation however among the undifferentiated febrile cases biopsy samples only 45% was adequate for evaluation. The sensitivity of bone marrow biopsy was 34%. There were 714 bone marrow aspiration samples of that 84% was adequate for evaluation. The most common etiological diagnosis for the undifferentiated fever from the marrow evaluation was visceral leishmaniasis (53%). The sensitivity of the bone marrow aspiration and aspiration or biopsy for visceral leishmaniasis was 95% and 98% respectively. (p value 0.03) Conclusion: Bone marrow aspiration is highly sensitive and specific for the diagnosis of visceral leishmaniasis among the undifferentiated fever at tropics in Nepal.


JMS SKIMS ◽  
2012 ◽  
Vol 15 (1) ◽  
pp. 74-75
Author(s):  
Mushtaq Ahmad ◽  
Farhana Siraj ◽  
Mubashir Ahmad ◽  
Shabir Ahmad

The cutaneous mucinosis are a heterogenous group of disorders in which mucin accumulates in the skin. A 66 years old man presented with asymptomatic flesh coloured papules on the extremities without any truncal involvement of 3 months duration. Histopathological examination of a lesional biopsy revealed unremarkable epidermis with dermis showing pallor and loosening of collagen bundles in mucin like deposition suggestive of cutaneous mucinosis. Patient was put on steroids and hydroxycholoroquinine. Three months later he presented with encephalopathy. Investigation revealed hypercalcaemia, reversal of albumin globulin ratio, azotemia. X-ray skull revealed lytic lesions. Bone marrow aspiration and bone marrow biopsy was suggestive of multiple myeloma. This is an unknown presentation, as localized cutaneous mucinosis is not associated with systemic disease. Patient was started on chemotherapy for multiple myeloma. JMS 2012;15(1):74-75.


2015 ◽  
Vol 4 (1) ◽  
pp. 12-14
Author(s):  
Nirajan Mainali ◽  
Neha Homagai ◽  
Pratap Sagar Tiwari ◽  
Arun Giri

Introduction: Bone marrow examination is an important diagnostic tool to evaluate various disorder including both neoplastic and non-neoplastic hematological diseases. The two most important techniques used for the diagnosis are bone marrow aspiration and bone marrow trephine biopsy which are complementary to each other.Aim and Objectives: To compare the diagnostic value of bone marrow aspiration and biopsy. Material and methods: A total of 88cases with both bone marrow aspiration and biopsy were included in the study. All the aspirate smears were routinely stained by Jenner Giemsa while the trephine biopsy sections were stained by routine Hematoxylin and Eosin stain.. All the smears and sections were reviewed and the findings on BMA and BMB were compared and the final correlation done.Result: Hypolastic marrow was the most common diagnosis followed by immune thrombocytopenic purpura (ITP). But the diagnostic accuracy of ITP on aspiration was 100 % in compare to hypoplastic marrow (81.25%). The diagnosis accuracy of BMA in our study was 84.09%.Conclusion: Bone marrow aspiration and biopsy complement each other. Bone marrow aspiration provides better study of the cell, whereas biopsy provides detail about the pattern of cellular distribution, hence when performed together it gives better diagnostic accuracy. Journal of Nobel College of Medicine Vol.4(1) 2015: 12-14


Sign in / Sign up

Export Citation Format

Share Document