Snare salvage technique for deformed WEB device after deployment

2020 ◽  
pp. neurintsurg-2020-016696
Author(s):  
Zaid Aljuboori ◽  
Dale Ding ◽  
Robert F James

The Woven EndoBridge (WEB) device is a new endovascular technology that allows safe and effective treatment of wide-neck bifurcation aneurysms without the need for dual antiplatelet therapy.1–4 The case is presented of a patient in their 50 s with a history of systemic lupus erythematosus and receiving warfarin for recurrent deep venous thrombosis and an unruptured right middle cerebral artery bifurcation aneurysm. The aneurysm was treated with a WEB SL aneurysm embolization device (MicroVention, Tustin, California, USA). After the final deployment, a technical error (inadvertent forward movement of the pusher) led to the deformation of the device along its longitudinal axis, leaving the aneurysm partially untreated. An Amplatz Goose Neck Microsnare was used to capture the proximal detachment marker and used gentle traction to restore the original shape of the device (video 1).5–7 A follow-up angiogram revealed a restoration of the device’s shape with a similar result during the 4- month follow-up angiogram.Video 1

2021 ◽  
pp. 1-7
Author(s):  
Nikolaos Mouchtouris ◽  
David Hasan ◽  
Edgar A. Samaniego ◽  
Fadi Al Saiegh ◽  
Ahmad Sweid ◽  
...  

OBJECTIVE Wide-neck bifurcation cerebral aneurysms have historically required either clip ligation or stent- or balloon-assisted coil embolization. This predicament led to the development of the Woven EndoBridge (WEB) aneurysm embolization system, a self-expanding mesh device that achieves intrasaccular flow disruption and does not require antithrombotic medications. The authors report their operative experience and 6-month follow-up occlusion outcomes with the first 115 aneurysms they treated via WEB embolization. METHODS The authors reviewed the first 115 cerebral aneurysms they treated by WEB embolization after FDA approval of the WEB embolization device (from February 2019 to January 2021). Data were collected on patient demographics and clinical presentation, aneurysm characteristics, procedural details, postembolization angiographic contrast stasis, and functional outcomes. RESULTS A total of 110 patients and 115 aneurysms were included in our study (34 ruptured and 81 unruptured aneurysms). WEB embolization was successful in 106 (92.2%) aneurysms, with a complication occurring in 6 (5.5%) patients. Contrast clearance was seen in the arterial phase in 14 (12.2%) aneurysms, in the capillary phase in 16 (13.9%), in the venous phase in 63 (54.8%), and no contrast was seen in 13 (11.3%) of the aneurysms studied. Follow-up angiography was performed on 60 (52.6%) of the aneurysms, with complete occlusion in 38 (63.3%), neck remnant in 14 (23.3%), and aneurysmal remnant in 8 (13.3%). Six (5.5%) patients required re-treatment for persistent aneurysmal residual on follow-up angiography. CONCLUSIONS The WEB device has been successfully used for the treatment of both unruptured and ruptured wide-neck bifurcation aneurysms by achieving intrasaccular flow diversion. Here, the authors have shared their experience with its unique technical considerations and device size selection, as well as critically reviewed complications and aneurysm occlusion rates.


2021 ◽  
Author(s):  
Daniel M Heiferman ◽  
Jeremy C Peterson ◽  
Kendrick D Johnson ◽  
Vincent N Nguyen ◽  
David Dornbos ◽  
...  

Abstract The Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, California) is an intrasaccular flow disruptor used for the treatment of both unruptured and ruptured intracranial aneurysms. WEB has been shown to have 54% complete and 85% adequate aneurysm occlusion rates at 1-yr follow-up.1 Residual and recurrent ruptured aneurysms have been shown to have a higher risk of re-rupture than completely occluded aneurysms.2 With increased utilization of WEB in the United States, optimizing treatment strategies of residual aneurysms previously treated with the WEB device is essential, including surgical clipping.3,4 Here, we present an operative video demonstrating the surgical clip occlusion of previously ruptured middle cerebral artery and anterior communicating artery aneurysms that had been treated with the WEB device and had sizable recurrence on follow-up angiography. Informed consent was obtained from both patients. Lessons learned include the following: (1) the WEB device is highly compressible, unlike coils; (2) proximal WEB marker may interfere with clip closure; (3) no evidence of WEB extrusion into the subarachnoid space; (4) no more scarring than expected in ruptured cases; and (5) clipping is a feasible option for treating WEB recurrent or residual aneurysms.


2021 ◽  
pp. neurintsurg-2021-017405
Author(s):  
Guilherme Aguiar ◽  
Jildaz Caroff ◽  
Cristian Mihalea ◽  
Jonathan Cortese ◽  
Jean-Baptiste Girot ◽  
...  

BackgroundWoven EndoBridge (WEB) device treatment of wide-neck bifurcation aneurysms has proved to be safe and effective, but the use of these devices in sidewall aneurysms has been reported only in a small number of case series.ObjectiveTo report our results in a cohort of consecutive patients in whom a WEB device was used as first-line treatment for posterior communicating artery (PComA) aneurysms.MethodsWe conducted a retrospective analysis of a prospectively maintained database of PComA aneurysms treated with a WEB device in our institution from June 1, 2012 to November 15, 2020. Clinical and radiological findings were evaluated at immediate and last follow-up.ResultsA total of 219 aneurysms were treated with a WEB device, including 15 PComA aneurysms in 15 patients, 10 of which were ruptured. Aneurysms were wide necked, with a mean aspect ratio of 1.6 (range 0.7–3.0) and a mean neck size of 4.2 mm (range 2.6–7.4 mm). No intraoperative rupture occurred and only one thromboembolic event was noted. Among the group with at least a 3-month digital subtraction angiography (DSA) follow-up, complete and adequate occlusion were obtained in 54% and 72%, respectively (average follow-up 13 months). Re-treatment was needed for two initially ruptured aneurysms. No procedure-related morbidity or mortality was reported.ConclusionThis series suggests the high safety profile of WEB devices even when used in off-label indications. Treatment with these devices seems to be a valuable strategy for ruptured wide-neck PComA aneurysms, avoiding the need for antiplatelet medication. However, occlusion rates should be investigated in further larger studies.


2016 ◽  
Vol 22 (3) ◽  
pp. 299-303 ◽  
Author(s):  
Yong-Hong Ding ◽  
Daying Dai ◽  
Dana Schroeder ◽  
Ramanathan Kadirvel ◽  
David F Kallmes

The dual-layer Woven EndoBridge (WEB) device (WEB II) is designed to improve the performance of the first-generation WEB device. This study was performed to evaluate the acute and chronic performance of WEB II for aneurysm occlusion in an elastase-induced aneurysm model in rabbits. We implanted WEB II devices in 36 elastase-induced aneurysms and followed up for one, three, six, and 12 months. Degree of aneurysm occlusion at follow-up was graded on the Web Occlusion Scale (WOS): Grade A, complete aneurysm occlusion; Grade B, complete occlusion with recess filling; Grade C, residual neck filling; and Grade D, residual aneurysm filling. Hematoxylin and eosin staining was performed for histological assessment of aneurysm healing. Grades A, B, C, and D aneurysm occlusion at one-month follow-up were noted in three (17%), three (17%), eight (44%), and four (22%) of 18 cases, respectively. At the three-month time point Grades A, B, C, and D were shown in two (33%), two (33%), one (17%), and one (17%) aneurysms. Six months after treatment, one (17%), two (33%), two (33%), and one (17%) cases demonstrated Grades A, B, C, and D occlusion. At the 12-month time point, Grades B, C, and D were shown in three (50%), two (33%), and one (17%) aneurysms. Histologic evaluation showed progressive thrombus organization within aneurysm lumen from one to 12 months. These results indicated that the WEB II device can achieve high rates of aneurysm occlusion over time in experimental aneurysms.


2018 ◽  
Vol 11 (4) ◽  
pp. 386-389 ◽  
Author(s):  
Cristian Mihalea ◽  
Simon Escalard ◽  
Jildaz Caroff ◽  
Léon Ikka ◽  
Aymeric Rouchaud ◽  
...  

BackgroundWoven EndoBridge (WEB) deployment remains challenging in aneurysms with a complex shape or orientation.ObjectiveTo show that embolization of wide-neck bifurcation aneurysms using the WEB device balloon remodeling-assisted technique is a feasible and elegant endovascular solution compared with other techniques, such as balloon remodeling or stent-assisted coiling.Materials and methods10 cases (10 aneurysms in 9 patients) of balloon remodeling-assisted WEB treatment of unruptured complex bifurcation aneurysms were treated in our institution and retrospectively analyzed. Details of clinical presentations, technical details, perioperative and postoperative complications, and outcomes were collected. Immediate and long-term angiographic results were also evaluated.ResultsAneurysms included six middle cerebral artery aneurysms, one anterior communicating artery aneurysm, one posterior communicating artery aneurysm, one basilar artery aneurysm, and one T-shaped carotid aneurysm. Mean dome width was 6.55 mm, mean neck size 4.5 mm, mean height 4.79 mm, and mean dome-to-neck ratio was 1:1.46. Treatment was performed exclusively with the balloon remodeling-assisted WEB technique in all cases. The device was successfully deployed in every case. Periprocedural thromboembolic or hemorrhagic events did not occur. The modified Rankin Scale score at discharge was 0 for all patients. At mid-term or long-term angiographic follow-up, adequate occlusion was observed in 7 aneurysms from 8 controlled cases (87.5%), and one patient (2 aneurysms) did not have angiographic follow-up.ConclusionThe balloon remodeling-assisted WEB technique seems to be a safe and effective solution for endovascular treatment of unruptured wide-neck bifurcation aneurysms with specific complex anatomy. However, further studies are needed to evaluate the rate of complications and long-term efficacy.


2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


2020 ◽  
pp. 159101992096834
Author(s):  
Nicolas K Khattar ◽  
Andrew C White ◽  
Aurora S Cruz ◽  
Shawn W Adams ◽  
Kimberly S Meyer ◽  
...  

Ruptured vertebrobasilar dissecting aneurysms require urgent, often challenging treatment as they have with a high re-hemorrhage rate within the first 24 hours. The patient is a 57-year-old woman who presented with severe-sudden onset headache. Further work up showed a ruptured dissecting aneurysm of the caudal loop of the posterior inferior cerebellar artery (PICA) with associated narrowing distally, in the ascending limb. The aneurysm was immediately occluded with a Woven Endobridge (WEB) device (MicroVention, Tustin, CA, USA) while flow diversion treatment of the diseased ascending limb was postponed. Follow-up angiography three months later showed complete occlusion of the aneurysm, as well as healing of the diseased distal vessel, obviating the need for further intervention. WEB embolization of a ruptured dissecting posterior circulation aneurysm provided an excellent outcome for this patient.


1991 ◽  
Vol 75 (4) ◽  
pp. 525-534 ◽  
Author(s):  
Mark E. Linskey ◽  
Laligam N. Sekhar ◽  
Joseph A. Horton ◽  
William L. Hirsch ◽  
Howard Yonas

✓ Of 43 cavernous sinus aneurysms diagnosed over 6½ years, 23 fulfilled indications for treatment; of these 19 were treated, eight surgically and 11 with interventional radiological techniques. Six small and two giant aneurysms were treated surgically: four were clipped, two were repaired primarily, and two were trapped with placement of a saphenous-vein bypass graft. Seven large and four giant aneurysms were treated with interventional radiological techniques: in five cases the proximal internal carotid artery (ICA) was sacrificed; one aneurysm was trapped with detachable balloons; and five were embolized with preservation of the ICA lumen. The mean follow-up period was 25 months. At follow-up examination, three patients in the surgical group were asymptomatic, two had improved, and three had worsened. Three of these patients had asymptomatic infarctions apparent on computerized tomography (CT) scans. At follow-up examination, four radiologically treated patients were asymptomatic, five had improved, two were unchanged, and none had worsened. One patient had asymptomatic and one minimally symptomatic infarction apparent on CT scans; both lesions were embolic foci after aneurysm embolization with preservation of the ICA. It is concluded that treatment risk depends more on the adequacy of collateral circulation than on the size of the aneurysm. A multidisciplinary treatment protocol for these aneurysms is described, dividing patients into high-, moderate-, and low-risk groups based on pretreatment evaluation of the risk of temporary or permanent ICA occlusion using a clinical balloon test occlusion coupled with an ICA-occluded stable xenon/CT cerebral blood flow study. Radiological techniques are suggested for most low-risk patients, while direct surgical techniques are proposed for most moderate- and high-risk patients.


Sign in / Sign up

Export Citation Format

Share Document