TECHNOLOGY REVIEW OF TWO-STAGE VAPOR COMPRESSION HEAT PUMP SYSTEM

2013 ◽  
Vol 21 (03) ◽  
pp. 1330002 ◽  
Author(s):  
KOJO ATTA AIKINS ◽  
SANG-HYEOK LEE ◽  
JONG MIN CHOI

There is increasing demand for domestic and industrial refrigeration, space heating and air conditioning. Heat pump systems offer economical alternatives for recovering heat from different sources for use in these applications. As a renewable energy technology for sustainable environment, the heat pump's high efficiency and low environmental impact have already drawn a fair amount of attention all over the world. Some of these domestic and industrial applications require very low evaporating temperatures and very high condensing temperatures which induce high compressor pressure ratios beyond the practical range for single-stage heat pump cycles. These high pressure ratios also produce low coefficient of performance (COP) values and expose the compressor to high discharge temperature, low volumetric efficiency and damage. However, this challenge can be overcome by adopting two-stage heat pump cycles. In this paper, recent works on two-stage heat pump systems for various applications are reviewed. They include two-stage cycle with intercooling, two-stage cycle with refrigerant injection and two-stage cascade cycle. Research and innovative designs of systems that make use of these two-stage cycles have been able to get heat pumps to handle applications with lower and higher temperatures, while enhancing heating capacity up to 30% and COP up to 31%.

Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3269 ◽  
Author(s):  
Zhongbao Liu ◽  
Fengfei Lou ◽  
Xin Qi ◽  
Yiyao Shen

Air source heat pumps (ASHPs) are widely recognized as energy-saving and environmentally friendly heating and air-conditioning equipment with broad applications. However, when conventional ASHPs are operated at a low ambient temperature, they suffer from problems such as high discharge temperature and low heating efficiency. To address these problems, this study designed a new type of dual evaporator combined with a compressor casing thermal storage heat pump system (DE-CCTS) on the basis of a low-temperature air source heat pump water heater with enhanced vapor injection (EVI). The proposed DE-CCTS used thermal storage phase change material (PCM), which was filled in the secondary evaporator (the thermal storage heat exchanger), to recover the waste heat of the compressor casing. Unlike that in the original system under different ambient temperatures, the suction temperature increased by 0.1–1 °C, the discharge temperature decreased by 0.1–0.5 °C, and the coefficient of performance (COP) of DE-CCTS increased by 0.85–4.72% under the proposed system. These effects were especially evident at low temperatures.


Author(s):  
AA Ammar ◽  
K Sopian ◽  
M Mohanraj

In this research, a photovoltaic-thermal collector assisted heat pump has been developed and tested its performance under the tropical climatic conditions of Malaysia. The refrigerants such as, R134a and R1234yf were selected based on its thermodynamic and thermo-physical properties. The temperature of the photovoltaic module was theoretically predicted under the influence of tube diameter, tube spacing and refrigerant mass flow rate. Further, the energy performance of the photovoltaic-thermal evaporator and the heat pump system are investigated experimentally. Finally, the economical feasibility of the photovoltaic-thermal collector evaporator was assessed for the period of 20 years. The results showed that, the tube spacing and diameter of the copper tubes used in the photovoltaic-thermal evaporator/collector using R134a and R1234yf were optimized to 80 mm and 12.7 mm, respectively. It was observed that, during the clear sunny day, the average photovoltaic module temperature was reduced to 30.9 °C under the influence of panel cooling using refrigerant. The output of the panel was enhanced by 21%–44% with increase in solar radiation from 400 W/m2 to 1000 W/m2. The coefficient of performance of the heat pump was varied from 4.8 to 6.84 with an average coefficient of performance of 5.8 during clear sunny days. The life cycle economic analysis indicated that, the photovoltaic-thermal collector evaporator assisted heat pump has a payback period of 3 years, whereas the reference photovoltaic system has a payback period of 8 years.


2019 ◽  
Vol 85 ◽  
pp. 07014
Author(s):  
Gheorghe Ilisei ◽  
Tiberiu Catalina ◽  
Marian Alexandru ◽  
Robert Gavriliuc

Underground energy sources are becoming increasingly popular and now geothermal heat pumps are frequently used to heat/cool different types of buildings, including for solar passive houses. This article aims at giving a contribution in the development of the thermal modelling of borehole heat storage systems, investigating the possibility of a GSHP (ground source heat pump) implementation with vertical boreholes in a solar passive house. A case study analysing a residential solar passive house is presented as a suitable modelling tool for the estimation of the thermal behaviour of GSHP systems by combining the outcome from different modelling programs. The software DesignBuilder, Earth Energy Designer and a sizing method for borehole’s length are used for producing the numerical results. The results highlight that the length of the borehole, a major index in estimating the system’s cost, is directly influenced by fundamental variables like thermal conductivity of grout or soil. Additionally, correlations between these parameters and the coefficient of performance of GSHP were made. Furthermore, the length of borehole is very important as it is responsible for almost half of the total installation cost and triggered a difference in electricity consumption of the GSHP up to 14%.


2014 ◽  
Vol 18 (5) ◽  
pp. 1673-1677
Author(s):  
Xian-Ping Zhang ◽  
Xin-Li Wei ◽  
Xiao-Wei Fan ◽  
Fu-Jun Ju ◽  
Lei Yang

As an efficient and energy conservation technology, heat pumps working with R22, which are scheduled to be phased out by Montreal Protocol, are widely used in China at present. The global deteriorating ecology environment would accelerate the phase-out time of R22 in developing countries. Therefore, as a matter of urgency, an eco-friendly substitute should be investigated in order to replace R22. Under this context, and with a consideration of the environmental protection, R744/R161 mixture refrigerant is proposed. R744/R161 mixture refrigerant?s condensation pressure is reduced and its flammability and explosivity are suppressed. A thermodynamic model is developed, and under the given working conditions, the performances of subcritical heat pump system using R744/R161 mixture of variable mass fraction are discussed and compared with those of the R22 system. The optimal mass fraction of R744/R161 is given, which corresponds to a maximal heating coefficient of performance. The simulation results show that R744/R161 mixture can work as a competitive alternative to R22 in heat pump system.


2021 ◽  
Vol 246 ◽  
pp. 06001
Author(s):  
Petri Pylsy ◽  
Jarek Kurnitski

The energy efficiency of existing apartment buildings is playing an important role in energy and climate targets. In Finland, mechanical exhaust ventilation system is commonly used in older apartment buildings. Hence, there could be an energy saving potential by an exhaust air heat pump system (EAHP). In this work two cases have been studied. Buildings were built in 1960’s and 1970’s and in renovation equipped with hybrid heating system: district heating and exhaust air heat pump system. Two years measurement data, 2018 and 2019, was collected to evaluate the performance of exhaust air heat pump systems. According to measurement data the monthly coefficient of performance (COP) was calculated as well as seasonal coefficient of performance (SCOP) was defined. The monthly COP values varied from 3,1 to 4,6 and SCOP values were about 3,7. Heating energy cost savings were 23-31 %. Energy performance class before and after EAHP installation was calculated. If at least 50 % of heating energy consumption was covered by EAHP then also energy performance class was improved.


Author(s):  
Fang Wang ◽  
Xiaowei Fan ◽  
Zhuangyu Guo ◽  
Lu Zhang ◽  
Huiyan Zheng

The off-design experimental performances of heat pump system using R125/R290 (25/75, mass fraction) blend are investigated by varying the mass flowrate of refrigerant blend. The influences of variable mass flowrate upon system coefficient of performance (COP), discharge temperature, temperature glide (GT) and temperature profile in condenser are analyzed, the system performance comparisons between R125/R290 and substituted refrigerant R22 are carried out. The results show that when the blend mass flowrate increases, compressor power increases linearly, the COP linearly increases at first and then gradually decreases, and an optimum COP of 3.04 is obtained when mixture mass flowrate reaches 1.12 kg/min. The compressor discharge temperature is almost decreased linearly whereas specific mass heating capacity is increased firstly and then it has a drop. The temperature differences between refrigerant and water at the inlet and in the middle of the condenser is gradually increased while the one at the outlet is decreased gradually with a heat transfer pinch point kept in the middle of the heat exchanger. Compared with that of R22, the overall performance has proved that the new refrigerant blend could be a promising substitute for R22, which are of significance for the application of the new refrigerant blends used in heat pump system.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2273
Author(s):  
Seung-Hoon Park ◽  
Yong-Sung Jang ◽  
Eui-Jong Kim

The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.


2021 ◽  
Vol 9 ◽  
Author(s):  
Hang Zou ◽  
Zhanqiang Liu ◽  
Enshen Long

The external ventilation conditions have a great influence on the heating performance of the air source heat pump (ASHP) systems. The outdoor units of residential household air source heat pumps are often installed in narrow spaces such as balconies. The ventilation conditions of the outdoor unit will influent the heating performance of the air source heat pump. It is necessary to study the effect of the outdoor unit ventilation conditions on the heating performance of residential household heat pumps. This paper experimentally studied the heating performances of an air source heat pump system with the outdoor unit mounted in a balcony in different external ventilation conditions. The results indicate that the ventilation conditions for the outdoor units have a significant effect on the heating performance of the system. When the inlet of the outdoor unit was close to the sliding door and completely blocked, the ventilation environment was the worst and the coefficient of performance (COP) was the lowest. In addition, the unfavorable ventilation environment could result in a reduction of the COP by 26.2%. When the inlet of the outdoor unit was partially blocked, the heating performance could be improved and the COP was also slightly improved. The great heating performance was obtained under the cross-ventilation condition. This paper can guide the design of the installation position of the household air source heat pump outdoor units in actual engineering.


HortScience ◽  
1994 ◽  
Vol 29 (4) ◽  
pp. 249a-249
Author(s):  
Eric A. Lavoie ◽  
Damien de Halleux ◽  
André Gosselin ◽  
Jean-Claude Dufour

The main objective of this research was to produce a simulated model that permitted the evaluation of operating costs of commercial greenhouse tomato growers with respect to heating methods (hot air, hot water, radiant and heat pumps) and the use of artificial lighting for 1991 and 1992. This research showed that the main factors that negatively influence profitability were energy consumption during cold periods and the price of tomatoes during the summer season. The conventional hot water system consumed less energy than the heat pump system and produced marketable fruit yields similar to those from the heat pump system. The hot water system was generally more profitable in regards to energy consumption and productivity. Moreover, investment costs were less; therefore, this system gives best overall financial savings. As for radiant and hot air systems, their overall financial status falls between that of the hot water system and the heat pump. The radiant system proved to be more energy efficient that the hot air system, but the latter produced a higher marketable fruit yield over the 2-year study.