scholarly journals Reduction of Metal Artifacts in Patients with Total Hip Arthroplasty with Slice-encoding Metal Artifact Correction and View-Angle Tilting MR Imaging

Radiology ◽  
2012 ◽  
Vol 265 (1) ◽  
pp. 204-214 ◽  
Author(s):  
Reto Sutter ◽  
Erika J. Ulbrich ◽  
Vladimir Jellus ◽  
Mathias Nittka ◽  
Christian W. A. Pfirrmann
2018 ◽  
Author(s):  
Benedikt Schwaiger ◽  
Alexandra Gersing ◽  
Daniela Muenzel ◽  
Julia Dangelmaier ◽  
Peter Prodinger ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Mark Selles ◽  
Vera H. Stuivenberg ◽  
Ruud H. H. Wellenberg ◽  
Loes van de Riet ◽  
Ingrid M. Nijholt ◽  
...  

Abstract Objective To quantify metal artifact reduction using 130 keV virtual monochromatic imaging (VMI) with and without orthopedic metal artifact reduction (O-MAR) in total hip arthroplasty. Methods Conventional polychromatic images and 130 keV VMI of a phantom with pellets representing bone with unilateral or bilateral prostheses were reconstructed with and without O-MAR on a dual-layer CT. Pellets were categorized as unaffected, mildly affected and severely affected. Results When 130 keV VMI with O-MAR was compared to conventional imaging with O-MAR, a relative metal artifact reduction in CT values, contrast-to-noise (CNR), signal-to-noise (SNR) and noise in mildly affected pellets (67%, 74%, 48%, 68%, respectively; p < 0.05) was observed but no significant relative metal artifact reduction in severely affected pellets. Comparison between 130 keV VMI without O-MAR and conventional imaging with O-MAR showed relative metal artifact reduction in CT values, CNR, SNR and noise in mildly affected pellets (92%, 72%, 38%, 51%, respectively; p < 0.05) but negative relative metal artifact reduction in CT values and noise in severely affected pellets (− 331% and -223%, respectively; p < 0.05), indicating aggravation of metal artifacts. Conclusion Overall, VMI of 130 keV with O-MAR provided the strongest metal artifact reduction.


2014 ◽  
Vol 44 (3) ◽  
pp. 353-359 ◽  
Author(s):  
Gunilla M. Müller ◽  
Björn Lundin ◽  
Thord von Schewelov ◽  
Markus F. Müller ◽  
Olle Ekberg ◽  
...  

Radiology ◽  
2012 ◽  
Vol 265 (3) ◽  
pp. 848-857 ◽  
Author(s):  
Eric Y. Chang ◽  
James L. McAnally ◽  
James R. Van Horne ◽  
Sheronda Statum ◽  
Tanya Wolfson ◽  
...  

2016 ◽  
Vol 27 (3) ◽  
pp. 1312-1321 ◽  
Author(s):  
Christoph A. Agten ◽  
Reto Sutter ◽  
Claudio Dora ◽  
Christian W. A. Pfirrmann

Sign in / Sign up

Export Citation Format

Share Document