Sensing Behaviour Investigation of Amperometric Electrochemical NH3 Sensor: Optimization of Lanthanum Gallate Based Electrolyte Composition

2020 ◽  
Vol 167 (11) ◽  
pp. 117508 ◽  
Author(s):  
R. Sharan ◽  
Mainak Roy ◽  
Atanu Dutta
Author(s):  
F. I. Grace ◽  
L. E. Murr

During the course of electron transmission investigations of the deformation structures associated with shock-loaded thin foil specimens of 70/30 brass, it was observed that in a number of instances preferential etching occurred along grain boundaries; and that the degree of etching appeared to depend upon the various experimental conditions prevailing during electropolishing. These included the electrolyte composition, the average current density, and the temperature in the vicinity of the specimen. In the specific case of 70/30 brass shock-loaded at pressures in the range 200-400 kilobars, the predominant mode of deformation was observed to be twin-type faults which in several cases exhibited preferential etching similar to that observed along grain boundaries. A novel feature of this particular phenomenon was that in certain cases, especially for twins located in the vicinity of the specimen edge, the etching or preferential electropolishing literally isolated these structures from the matrix.


2020 ◽  
Vol 86 (10) ◽  
pp. 18-22
Author(s):  
K. N. Vdovin ◽  
K. G. Pivovarova ◽  
N. A. Feoktistov ◽  
T. B. Ponamareva

Zinc sulfate is the main component in the composition of the acidic zinc plating electrolyte. Deviation in the electrolyte composition from the optimum content leads to destabilization of the electrolysis process and deteriorate the quality of the resulting zinc coating. The proper quality of a zinc coating obtained by galvanic deposition can be ensured only with timely monitoring and adjustment of the electrolyte composition. A technique of X-ray fluorescence determination of zinc (in terms of zinc sulfate) in an acidic zinc plating electrolyte is proposed. The study was carried out using an ARL Quant’X energy dispersive spectrometer (Thermo Fisher Scientific, USA) with a semiconductor silicon-lithium detector. The features of the spectrometer design are presented. The optimal parameters of excitation and detection of zinc radiation were specified when the electrolyte sample was diluted 1:1000. The ZnKα1 line was used as an analytical line. The plotted calibration graph is linear, the correlation coefficient being 0.999234. The results of zinc determination according to the developed method were compared with the data of the reference method of complexometric titration to prove the reliability of the procedure. The results are characterized by good convergence and accuracy. The proposed method of X-ray fluorescence zinc determination in a zinc plating electrolyte equals complexometric titration in the limiting capabilities and even exceeds the latter in terms of the simplicity of sample preparation and rapidity. The developed method of X-ray fluorescence determination of zinc is implemented in analysis of the electrolyte used in the continuous galvanizing unit at «METSERVIS LLC».


2021 ◽  
Vol 25 (10) ◽  
pp. 6947-6956
Author(s):  
J. Prakash ◽  
S. Harshavardhan Naidu ◽  
Izzatdin Abdul Aziz ◽  
Jafreezal Jaafar

Author(s):  
Xing Ding ◽  
Batyr Garlyyev ◽  
Sebastian Watzele ◽  
Theophilus Sarpey ◽  
Aliaksandr Bandarenka

2011 ◽  
Vol 520 (3) ◽  
pp. 904-908 ◽  
Author(s):  
A.V. Marikutsa ◽  
M.N. Rumyantseva ◽  
A.M. Gaskov ◽  
E.A. Konstantinova ◽  
D.A. Grishina ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document