Effect of continuous and pulse DC on processing time, electrolyte composition and electrolyte concentration of electrochemical honing

2015 ◽  
Vol 5 (3/4) ◽  
pp. 173 ◽  
Author(s):  
H. Singh ◽  
P.K. Jain
2017 ◽  
Vol 199 ◽  
pp. 63-73 ◽  
Author(s):  
Nico E. A. Cousens ◽  
Anthony R. J. Kucernak

Electrowetting-on-dielectric devices typically have operating voltages of 10–20 V. A reduction in the operating voltage could greatly reduce the energy consumption of these devices. Herein, fully reversible one-electrolyte electrowetting of a droplet on a solid metal surface is reported for the first time. A reversible change of 29° for an 800 mV step is achieved. The effects of surface roughness, electrolyte composition, electrolyte concentration and droplet composition are investigated. It was found that there is a dramatic dependence of the reversibility and hysteresis of the system on these parameters, contrary to theoretical predictions. When a 3-chloro-1-propanol droplet is used, a system with no hysteresis and a 40° change in angle are obtained.


Author(s):  
F. I. Grace ◽  
L. E. Murr

During the course of electron transmission investigations of the deformation structures associated with shock-loaded thin foil specimens of 70/30 brass, it was observed that in a number of instances preferential etching occurred along grain boundaries; and that the degree of etching appeared to depend upon the various experimental conditions prevailing during electropolishing. These included the electrolyte composition, the average current density, and the temperature in the vicinity of the specimen. In the specific case of 70/30 brass shock-loaded at pressures in the range 200-400 kilobars, the predominant mode of deformation was observed to be twin-type faults which in several cases exhibited preferential etching similar to that observed along grain boundaries. A novel feature of this particular phenomenon was that in certain cases, especially for twins located in the vicinity of the specimen edge, the etching or preferential electropolishing literally isolated these structures from the matrix.


Author(s):  
James C. Long

Over the years, many techniques and products have been developed to reduce the amount of time spent in a darkroom processing electron microscopy negatives and micrographs. One of the latest tools, effective in this effort, is the Mohr/Pro-8 film and rc paper processor.At the time of writing, a unit has been recently installed in the photographic facilities of the Electron Microscopy Center at Texas A&M University. It is being evaluated for use with TEM sheet film, SEM sheet film, 35mm roll film (B&W), and rc paper.Originally designed for use in the phototypesetting industry, this processor has only recently been introduced to the field of electron microscopy.The unit is a tabletop model, approximately 1.5 × 1.5 × 2.0 ft, and uses a roller transport method of processing. It has an adjustable processing time of 2 to 6.5 minutes, dry-to-dry. The installed unit has an extended processing switch, enabling processing times of 8 to 14 minutes to be selected.


1996 ◽  
Vol 8 (1) ◽  
pp. 1-10 ◽  
Author(s):  
Ken Bartley

This paper discusses the need for nationally based analytical models of the medieval period. The use of cluster analysis as a method for classifying demesne farms, by the crops they grew and their livestock management, is explained. Successful implementation of cluster analysis requires both the existence of a large base sample, to permit isolation of specific groupings within the data, and access to considerable processing time. The paper concludes by demonstrating how discriminant analysis can provide an efficient and systematic way of classifying even a single manor within a national frame of reference.


Author(s):  
Gennadiy Valentinovich Alexeev ◽  
Elena Igorevna Verboloz

The article focuses on the process of intensive mixing of liquid phase in the tin during high-temperature sterilization, i.e. sterilization when temperature of the heat carrier reaches 150-160°C. It has been stated that for intensification of the thermal process during sterilization of tinned fish with liquid filling it is preferable to turn a tin from bottom to top. This operation helps to increase the driving power of the process and to shorten warming time. Besides, high-temperature sterilization carried out according to experimental modes, where the number of tin turnovers is calculated, greatly shortens processing time and improves quality of the product. In this case there is no superheating, all tins are evenly heated. The study results will contribute to equipment modernization and to preserving valuable food qualities.


2017 ◽  
Author(s):  
O Pong-Sik ◽  
Ryang Se-Hun ◽  
Sin Gum-Chol ◽  
Hwang Guk-Nam ◽  
yongson hong

We have studied porous anodic alumina template through the second anodic oxidation of preparation. Observing the morphology of nanoscale AAO template using scanning electron microscope (SEM), the results indicate that the pores are orderly paralleled arranged with uniform pore diameter, perpendicular to the template surface. A detailed study of the influence of different oxidation conditions, such as different type of electrolyte, concentration, voltage and temperature on the template of alumina and its electrochemical mechanism were performed. By changing the oxidation voltage, electrolyte type, concentration, pore diameter and template thickness can be altered in a wide range such that we can obtain the desired aspect ratio. <br>


Sign in / Sign up

Export Citation Format

Share Document