scholarly journals Determination of Electrolyte Transport Properties with a Multi-Reference-Electrode Cell

Author(s):  
Clément Rabette ◽  
Issyan Tekaya ◽  
Mohammad Farkhondeh ◽  
Benoît Fleutot ◽  
Charles Delacourt
2020 ◽  
Vol MA2020-01 (1) ◽  
pp. 132-132
Author(s):  
Clément Rabette ◽  
Tristan Lombard ◽  
Jean-Paul Chehab ◽  
Mohammad Farkhondeh ◽  
Benoit Fleutot ◽  
...  

Author(s):  
P Bijster ◽  
H L Vader ◽  
C L J Vink

We have shown that the sodium concentration in whole blood measured by direct potentiometry is higher than in plasma. The ‘erythrocyte-effect’, already described by Siggaard Andersen, is most pronounced for instruments equipped with a reference electrode with an open static liquid junction and is thus a general phenomenon. Instruments with a modified liquid junction show less interference. The same phenomenon appears for the determination of the potassium concentration, although the difference between whole blood and plasma, when measured with instruments equipped with a modified liquid junction, can be neglected in practice.


1983 ◽  
Vol 81 (1-2) ◽  
pp. 135-147 ◽  
Author(s):  
U. Thanei-Wyss ◽  
W. E. Morf ◽  
P. Lienemann ◽  
Z. Stefanac ◽  
I. Mostert ◽  
...  

1972 ◽  
Vol 27 (5) ◽  
pp. 794-803 ◽  
Author(s):  
R Müller ◽  
W Walcher ◽  
H.-W Wassmuth

AbstractThree methods for the measurement of the change ΔΦ of the work function Φ of a metal surface due to the presence of adsorbed particles (e. g. oxygen) have been developed utilizing the surface ionization of a beam of metal atoms (e. g. In, Sr) as a probe. The experiments have been performed with a mass spectrometer at ultrahigh vacuum.In the first method the temperature dependency of the ion emission current is used for the determination of the work function Φ considering certain limiting conditions. The two other methods which may be applied simultaneously with the first one, involve a direct measurement of ΔΦ by compensating the change of the contact potential by an external voltage: In the second method the contact potential between the ionizing surface and a surrounding reference electrode is used to control the ion optical conditions for the ion emission, whereas in the third method the change in the kinetic energy of the ions caused by a change of the contact potential between the ionizing surface and the entrance slit of the mass spectrometer is used as a measure of ΔΦ


2010 ◽  
Vol 7 (3) ◽  
pp. 284-287
Author(s):  
Ani Mulyasuryani ◽  
Qonitah Fardiyah ◽  
Rizki Sugiri

The iodate-selective electrode based on the principle of precipitation reaction could be made by coating the platinum wire with silver iodate (AgIO3). In this research was carried out optimization the iodate-selective electrode using chitosan membrane as an AgIO3 support. The AgIO3 were added in the 2 mL 1% chitosan solution, is 0.5 to 2.5 % (w/v). The thickness of the membrane used is 6 to 12 µm. The electrode cell potential is measured against Ag/AgCl electrode as a reference electrode. The optimum electrode performance was at 2.0 % of AgIO3 with thickness a membrane of 10 µm. The iodate-selective electrode has a Nernstian factor is 52.96 mV/decade and a response time of 10 seconds. The concentration range was determined from 10-3 M to 10-1 M and the detection limit is 1.12 x 10-5 M.   Keywords:  Ion Selective Electrode, Iodate, Chitosan Membrane


Sign in / Sign up

Export Citation Format

Share Document