scholarly journals Estimation of coronary wave intensity analysis using noninvasive techniques and its application to exercise physiology

2016 ◽  
Vol 310 (5) ◽  
pp. H619-H627 ◽  
Author(s):  
Christopher J. Broyd ◽  
Sukhjinder Nijjer ◽  
Sayan Sen ◽  
Ricardo Petraco ◽  
Siana Jones ◽  
...  

Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. −13.8 ± 7.1 × 104 W·m−2·s−2, concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: −64.4 ± 32.8 vs. −59.4 ± 34.2 × 102 W·m−2·s−1, CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction ( r = −0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was −47.0 ± 29.5 × 104 W·m−2·s−2 ( P < 0.01 vs. rest) and cumulative BDW −19.2 ± 12.6 × 103 W·m−2·s−1 ( P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA.

2017 ◽  
Vol 2017 (1) ◽  
Author(s):  
C J Broyd ◽  
J E Davies ◽  
J E Escaned ◽  
A Hughes ◽  
K Parker

Wave intensity analysis (WIA) is a technique developed from the field of gas dynamics that is now being applied to assess cardiovascular physiology. It allows quantification of the forces acting to alter flow and pressure within a fluid system, and as such it is highly insightful in ascribing cause to dynamic blood pressure or velocity changes.When co-incident waves arrive at the same spatial location they exert either counteracting or summative effects on flow and pressure. WIA however allows waves of different origins to be measured uninfluenced by other simultaneously arriving waves. It therefore has found particular applicability within the coronary circulation where both proximal (aortic) and distal (myocardial) ends of the coronary artery can markedly influence blood flow. Using these concepts, a repeating pattern of 6 waves has been consistently identified within the coronary arteries, 3 originating proximally and 3 distally. Each has been associated with a particular part of the cardiac cycle. The most clinically relevant wave to date is the backward decompression wave, which causes the marked increase in coronary flow velocity observed at the start of the diastole. It has been proposed that this wave is generated by the elastic re-expansion of the intra-myocardial blood vessels that are compressed during systolic contraction. Particularly by quantifying this wave, WIA has been used to provide mechanistic and prognostic insight into a number of conditions including aortic stenosis, left ventricular hypertrophy, coronary artery disease and heart failure. It has proven itself to be highly sensitive and as such a number of novel research directions are encouraged where further insights would be beneficial. 


2007 ◽  
Vol 292 (3) ◽  
pp. H1533-H1540 ◽  
Author(s):  
Tracy N. Hobson ◽  
Jacqueline A. Flewitt ◽  
Israel Belenkie ◽  
John V. Tyberg

The left atrium (LA) acts as a booster pump during late diastole, generating the Doppler transmitral A wave and contributing incrementally to left ventricular (LV) filling. However, after volume loading and in certain disease states, LA contraction fills the LV less effectively, and retrograde flow (i.e., the Doppler Ar wave) into the pulmonary veins increases. The purpose of this study was to provide an energetic analysis of LA contraction to clarify the mechanisms responsible for changes in forward and backward flow. Wave intensity analysis was performed at the mitral valve and a pulmonary vein orifice. As operative LV stiffness increased with progressive volume loading, the reflection coefficient (i.e., energy of reflected wave/energy of incident wave) also increased. This reflected wave decelerated the forward movement of blood through the mitral valve and was transmitted through the LA, accelerating retrograde blood flow in the pulmonary veins. Although total LA work increased with volume loading, the forward hydraulic work decreased and backward hydraulic work increased. Thus wave reflection due to increased LV stiffness accounts for the decrease in the A wave and the increase in the Ar wave measured by Doppler.


2012 ◽  
Vol 302 (7) ◽  
pp. H1481-H1491 ◽  
Author(s):  
Pong-Jeu Lu ◽  
Chi-Fu Jeffrey Yang ◽  
Meng-Yu Wu ◽  
Chun-Hao Hung ◽  
Ming-Yao Chan ◽  
...  

Wave intensity analysis (WIA) was used to delineate and maximize the efficacy of a newly developed para-aortic blood pump (PABP). The intra-aortic balloon pump (IABP) was employed as the comparison benchmark. Acute porcine experiments using eight pigs, randomly divided into IABP ( n = 4) and PABP ( n = 4) groups, were conducted to compare the characteristics of intra- and para-aortic counterpulsation. We measured pressure and velocity with probes installed in the left anterior descending coronary artery and aorta, during and without PABP assistance. Wave intensity for aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction applied. To achieve maximized support efficacy, deflation timings ranging from 25 ms ahead of to 35 ms after the R-wave were tested. Similar to those associated with IABP counterpulsation, the PABP-generated backward-traveling waves predominantly drove aortic and coronary blood flows. However, in contrast with IABP counterpulsation, the nonocclusive nature of the PABP allowed systolic unloading to be delayed into early systole, which resulted in near elimination of coronary blood steal without diminution of systolic left ventricular ejection wave intensities. WIA can elucidate subtleties among different counterpulsatile support means with high sensitivity. Total accelerating wave intensity (TAWI), which was defined as the sum of the time integration of accelerated parts of the positive and negative wave intensities, was used to quantify counterpulsation efficacy. In general, the larger the TAWI gain, the better the counter-pulsatile support efficacy. However, when PABP deflation timings were delayed to after the R-wave, the TAWI was found to be inversely correlated with coronary perfusion. In this delayed deflation timing setting, greater wave cancellation occurred, which led to decreased TAWI but increased coronary perfusion attributed to blood regurgitation reduction.


2004 ◽  
Vol 286 (1) ◽  
pp. H267-H275 ◽  
Author(s):  
Ellen H. Hollander ◽  
Gary M. Dobson ◽  
Jiun-Jr Wang ◽  
Kim H. Parker ◽  
John V. Tyberg

Pressure waves are thought to travel from the left atrium (LA) to the pulmonary artery (PA) only retrogradely, via the vasculature. In seven anesthetized open-chest dogs, a balloon was placed in the LA, which was rapidly inflated and deflated during diastole, early systole, and late systole. High-fidelity pressures were measured within and around the heart. Measurements were made at low volume [LoV; left ventricular end-diastolic pressure (LVEDP) = 5–9 mmHg], high volume (HiV; LVEDP = 16–19 mmHg), and HiV with the pericardium removed. Wave-intensity analysis demonstrated that, except during late systole, balloon inflation created forward-going PA compression waves that were transmitted directly through the heart without measurable delay; backward PA compression waves were transmitted in-series through the pulmonary vasculature and arrived after delays of 90 ± 3 ms (HiV) and 103 ± 5 ms (LoV; P < 0.05). Direct transmission was greater during diastole, and both direct and series transmission increased with volume loading. Pressure waves from the LA arrive in the PA by two distinct routes: rapidly and directly through the heart and delayed and in-series through the pulmonary vasculature.


2014 ◽  
Vol 10 (1) ◽  
pp. 17-23 ◽  
Author(s):  
Sayan Sen ◽  
Ricardo Petraco ◽  
Jamil Mayet ◽  
Justin Davies

Sign in / Sign up

Export Citation Format

Share Document