Cantilever transducer for continuous measurement of arterial diameter in vivo

1971 ◽  
Vol 31 (6) ◽  
pp. 948-953 ◽  
Author(s):  
J. P. Murgo ◽  
R. H. Cox ◽  
L. H. Peterson
1972 ◽  
Vol 32 (5) ◽  
pp. 728-733 ◽  
Author(s):  
D E Hokanson ◽  
D J Mozersky ◽  
D S Sumner ◽  
D E Strandness

1971 ◽  
Vol 118 (545) ◽  
pp. 465-466 ◽  
Author(s):  
Ngo Tran ◽  
Marcel Laplante ◽  
Etienne Lebel

The decarboxylation of 3, 4-dihydroxyphenyl-alanine (Dopa) to dopamine has been shown previously in animal and human tissues in both in vitro and in vivo studies (Sourkes, 1966; Vogel et al., 1970). However, very little information is available as to whether or not the decarboxylation of Dopa occurs in human red blood cells (RBC). In the present experiment we demonstrated this change in RBC from normals and from schizophrenics. An ionization chamber method was used for an instantaneous and continuous measurement of 14CO2 production from DL-dopa-carboxyl-14C by RBC in vitro.


Author(s):  
Ahmed M. Mahmoud ◽  
Phoebe A. Stapleton ◽  
Jefferson C. Frisbee ◽  
Osama M. Mukdadi

Atherosclerosis has become one of the contributing factors of cardiovascular diseases. Endothelial dysfunction is considered a key factor in the development of atherosclerosis [1]. Flow-mediated vasodilatation (FMD) measurement in brachial and other conduit arteries has become a common method to asses the endothelial function in vivo [2]. Fluid shear-stress increases due to blood flow increases, thus stimulating endothelial cell production and release of nitric oxide, a potent endogenous vasodilator. The mechanical behavior of the arterial wall during vasodilatation is considered an indication for endothelial health. In FMD measurement, the endothelium-dependent variation in arterial diameter in response to reactive ischemia-induced hyperemia is measured by comparing the luminal diameter of the brachial artery before and after the ischemia of the forearm induced by pressurizing a cuff [3]. Ultrasound imaging modalities has been widely used in the FMD analysis as a noninvasive low-cost tool, which can be used to track the arterial diameter change with time. Most of the FMD measurements in the literature are based on tracing the vessel wall boundary manually. Since this process is time consuming and may introduce human errors, automatic measurement techniques have been implemented [3,4]. These techniques utilize image processing algorithms to identify the edges of arterial walls, and then calculate the relative displacement change with time.


2019 ◽  
Vol 33 (1) ◽  
pp. 32-38
Author(s):  
Kuizhong Wang ◽  
Peng Jin ◽  
Peigang Lu ◽  
Qiang Liu ◽  
Bo Li ◽  
...  

Background Flow diverters (FDs) with flared ends (FEs) or straight ends (SEs) are used either alone or when overlapped to treat complex intracranial aneurysms. We evaluated filament inadequate wall apposition (IWA) of the FEs and SEs of FDs in vivo. Methods A total of 24 FDs with FEs and SEs were placed in an overlapping manner in the abdominal aortae of six rabbits (two sets per rabbit). Digital subtraction angiography was performed immediately after stent insertion and three months later. The anatomical and histopathological aortic features at FEs and SEs were evaluated. Results Angiography revealed no significant difference in terms of changes in arterial diameter between the FE and SE groups ( p = 0.877). Gross anatomical evaluation revealed IWA of the different ends of FDs but no thrombi or bleeding, showing that the metallic filaments were not in touch with the vessel wall and nor had they penetrated the vessel wall. The filaments’ IWA rates of FEs and SEs were 8.33% and 8.85%, respectively. The IWA rate at overlapping ends was lower than that at non-overlapping ends. The maximum neo-intimal thickness at FEs was greater than that at SEs (149.4 ± 48.9 and 98.6 ± 26.6 µm, respectively; p < 0.001). Conclusions Both the FEs and SEs of FDs can exhibit IMA. IWA events are reduced at the overlapped regions. On pathological evaluation, FEs increased neo-intimal thicknesses more than SEs did, but hyperplasia was minimal on angiography.


Sign in / Sign up

Export Citation Format

Share Document