Effect of nocturnal atrial demand cardiac pacing on diurnal hemodynamic patterns

1992 ◽  
Vol 72 (5) ◽  
pp. 1798-1802 ◽  
Author(s):  
B. T. Engel ◽  
M. I. Talan ◽  
P. H. Chew

Heart rate (HR), stroke volume (SV), intra-arterial blood pressure, and central venous pressure were recorded on a beat-to-beat basis, 18 h/day (1800–1200 h the following day), for approximately 2 mo in four monkeys (Macaca mulatta). Cardiac output, left ventricular work, and total peripheral resistance were derived from these primary measurements. During the 1st mo we measured these parameters under control conditions, and during the 2nd mo the animals were studied while HR was paced by atrial demand pacing sufficient to prevent the normal nocturnal fall in HR (approximately 10 beats/min above the fastest hourly average rate recorded during the control condition). The main hypothesis of this study was that when HR is prevented from falling, SV, which normally does not fall overnight, would fall; this hypothesis was confirmed. In addition, we observed that, during the period of pacing, relative to the control period, SV was approximately 14% greater during the early evening and 4% lower during the early morning; total peripheral resistance was similar during the early evening but was 13% higher by morning. Throughout the night, systolic pressure was approximately 4% greater, diastolic pressure was 17% higher, central venous pressure was 43% greater, and left ventricular work was 27% higher. These findings show that when HR is prevented from falling overnight by atrial demand pacing, even to a relatively modest degree, there can be very significant sustained changes in cardiovascular function.

1992 ◽  
Vol 72 (5) ◽  
pp. 1803-1809 ◽  
Author(s):  
M. I. Talan ◽  
B. T. Engel ◽  
P. H. Chew

Beat-to-beat parameters of heart rate (HR), intra-arterial blood pressure (BP), central venous pressure, and derived indexes of cardiac output and total peripheral resistance were recorded 18 h/day (from 1800 to 1200 h the following day) in four monkeys (Macaca mulatta) during 20 control days followed by 20 days of atrial demand pacing. The pacing rate was set at approximately 10 beats/min above the fastest hourly average HR recorded during the control period, i.e., sufficient to prevent the normal nocturnal fall in HR. Nocturnal pacing resulted in progressive weekly increases in central venous BP and arterial BP. Analyses of levels and diurnal trends in hemodynamic parameters and cardiac function curves across consecutive 5-day periods of nocturnal pacing revealed a hemodynamic pattern characteristic of high-output heart failure, which progressively increased (week by week) during the early morning hours (0500–0700). Sustained elevated left ventricular work resulting from the prevention of a nocturnal fall in HR may have been responsible for the reduction in cardiac function seen in this experimental model.


1978 ◽  
Vol 06 (03) ◽  
pp. 253-259
Author(s):  
DONALD H. CLIFFORD ◽  
DO CHIL LEE ◽  
CHONG YUL KIM ◽  
MYUNG O. LEE

An electromagnetic flowmeter probe was chronically implanted around the ascending aorta in a group of dogs. Subsequently, ten dogs were lightly anesthetized with halothane (0.75%), and a third (aqueous) extract of ginseng (40 mg/kg) was administered intravenously. Five dogs were anesthesized without the administration of ginseng. Eleven cardiovascular variables including cardiac output, stroke volume, heart rate, mean arterial pressure, pulse pressure, central venous pressure, total peripheral resistance, pH, PaCO2, PaO2, and base deficit were compared. The cardiac output, stroke volume, and central venous pressure were decreased significantly, while total peripheral resistance was increased significantly following ginseng.


1993 ◽  
Vol 74 (4) ◽  
pp. 1684-1688 ◽  
Author(s):  
B. T. Engel ◽  
M. I. Talan ◽  
P. H. Chew

We compared the nocturnal hemodynamic patterns of seven tethered monkeys (Macaca mulatta) with those of seven chaired animals to determine whether the overnight changes are comparable in the two conditions. In both groups, we found a consistent hemodynamic pattern characterized by an overnight fall in cardiac output and central venous pressure and a rise in total peripheral resistance that maintained blood pressure homeostasis. The pattern of overnight change occurred despite major differences in response levels: cardiac output and central venous pressure were significantly elevated, and total peripheral resistance was significantly reduced at all times (from 1800 to 1200 h the following day) in the chaired animals relative to the tethered animals. This difference was probably due to an expanded plasma volume in the chaired animals, because stroke volume was also significantly elevated. Because the nocturnal hemodynamic pattern occurred under both conditions, it is likely that it is a stable biologic effect, which is probably related to an overnight loss in fluid volume that is not replaced in animals that sleep throughout the night.


1965 ◽  
Vol 209 (6) ◽  
pp. 1081-1088 ◽  
Author(s):  
G. Ascanio ◽  
F. Barrera ◽  
E. V. Lautsch ◽  
M. J. Oppenheimer

Intracoronary administration of hexachlorotetrafluorobutane (Hexa) into non-thoracotomized dogs produced a statistically significant decrease in left ventricular systolic pressure (LVSP), mean femoral arterial blood pressure (MFAP), first derivative of left ventricular pressure pulse (dP/d t), total peripheral resistance (TPR), and cardiac output (C.O.) lasting up to 1 hr after injection. Femoral vascular resistance decreased during the first 3 min after production of necrobiosis. Fifty percent of the dogs died of ventricular fibrillation (VF) after Hexa infarction. Prereserpinized dogs did not show significant changes in the parameters which were significantly changed in normal dogs after Hexa necrobiosis except in the case of VF which was almost absent in this group. Bilateral vagotomy prior to Hexa administration prevented most hemodynamic changes after necrobiosis whereas atropine did not. Bilateral vagotomy and atropine 1 hr after necrobiosis increased MFAP, dP/d t, LVSP, C.O., and TPR. Apparently excitatory efferent sympathetic activity on heart and femoral arterial vessels is reflexly inhibited by the effects of intracoronary injection of Hexa. The afferent pathway is via the vagus nerve.


1991 ◽  
Vol 260 (1) ◽  
pp. H254-H259
Author(s):  
R. Maass-Moreno ◽  
C. F. Rothe

We tested the hypothesis that the blood volumes of the spleen and liver of cats are reflexly controlled by the carotid sinus (CS) baroreceptors. In pentobarbital-anesthetized cats the CS area was isolated and perfused so that intracarotid pressure (Pcs) could be controlled while maintaining a normal brain blood perfusion. The volume changes of the liver and spleen were estimated by measuring their thickness using ultrasonic techniques. Cardiac output, systemic arterial blood pressure (Psa), central venous pressure, central blood volume, total peripheral resistance, and heart rate were also measured. In vagotomized cats, increasing Pcs by 100 mmHg caused a significant reduction in Psa (-67.8%), cardiac output (-26.6%), total peripheral resistance (-49.5%), and heart rate (-15%) and significantly increased spleen volume (9.7%, corresponding to a 2.1 +/- 0.5 mm increase in thickness). The liver volume decreased, but only by 1.6% (0.6 +/- 0.2 mm decrease in thickness), a change opposite that observed in the spleen. The changes in cardiovascular variables and in spleen volume suggest that the animals had functioning reflexes. These results indicate that in pentobarbital-anesthetized cats the carotid baroreceptors affect the volume of the spleen but not the liver and suggest that, although the spleen has an active role in the control of arterial blood pressure in the cat, the liver does not.


1959 ◽  
Vol 197 (5) ◽  
pp. 1005-1007 ◽  
Author(s):  
Calvin Hanna ◽  
Patricia B. McHugo ◽  
William H. MacMillan

The cardiovascular actions of intravenous histamine, in doses from 2.5 to 20 µg/kg of the free base, were studied in the pentobarbitalized dog using the dye dilution method. With the small dose there was a consistent but small initial increase in cardiac output and with the larger doses there was a biphasic change in output. Cardiac rate, central venous pressure, central blood volume, hematocrit and the mean circulation time were essentially unchanged. Infusions of histamine and of potassium chloride at the rate of 1 µg and 1 mg/kg/min., respectively, moderately increased the cardiac output. Potassium chloride had no effect on the arterial blood pressure, cardiac rate and central venous pressure. Both the infusion of potassium chloride and injection of histamine produced a comparable elevation of the plasma potassium. It is possible that the actions of histamine to increase the plasma potassium contribute to the cardiovascular actions of this amine, especially on the cardiac output.


1982 ◽  
Vol 62 (1) ◽  
pp. 51-56 ◽  
Author(s):  
R. Hatton ◽  
D. P. Clough ◽  
S. A. Adigun ◽  
J. Conway

1. Lower-body negative pressure (LBNP) was used to stimulate sympathetic reflexes in anaesthetized cats. At −50 mmHg for 10 min it caused transient reduction in central venous pressure and systemic arterial blood pressure. Arterial blood pressure was then restored within 30 s and there was a tachycardia. Central venous pressure showed only partial recovery. The resting level of plasma renin activity (PRA; 2.9–3.2 ng h−1 ml−1) did not change until approximately 5 min into the manoeuvre. 2. When converting-enzyme inhibitor (CEI) was given 75 s after the onset of suction it caused a greater and more sustained fall in arterial blood pressure than when administered alone. The angiotensin II (ANG II) antagonist [Sar1,Ala8]ANG II produced similar effects after a short-lived pressor response. 3. This prolonged fall in arterial blood pressure produced by CEI was not associated with reduced sympathetic efferent nerve activity. This indicates that the inhibitor affects one of the peripheral actions of angiotensin and in so doing produces vasodilatation of neurogenic origin. 4. These findings suggest that angiotensin, at a level which does not exert a direct vasoconstrictor action, interacts with the sympathetic nervous system to maintain arterial blood pressure when homeostatic reflexes are activated. A reduction in the efficiency of these reflexes by CEI may contribute to its hypotensive effect.


Author(s):  
Ali İhsan Hasde ◽  
Mehmet Cahit Sarıcaoğlu ◽  
Nur Dikmen Yaman ◽  
Çağdaş Baran ◽  
Evren Özçınar ◽  
...  

Abstract OBJECTIVES Our goal was to compare the haemodynamic effects of different mechanical left ventricular (LV) unloading strategies and clinical outcomes in patients with refractory cardiogenic shock supported with venoarterial extracorporeal membrane oxygenation (VA-ECMO). METHODS A total of 448 patients supported with VA-ECMO for refractory cardiogenic shock between 1 March 2015 and 31 January 2020 were included and analysed in a single-centre, retrospective case–control study. Fifty-three patients (11.8%) on VA-ECMO required LV unloading. Percutaneous balloon atrial septostomy (PBAS), intra-aortic balloon pump (IABP) and transapical LV vent (TALVV) strategies were compared with regards to the composite rate of death, procedure-related complications and neurological complications. The secondary outcomes were reduced pulmonary capillary wedge pressure, pulmonary artery pressure, central venous pressure, left atrial diameter and resolution of pulmonary oedema on a chest X-ray within 48 h. RESULTS No death related to the LV unloading procedure was detected. Reduction in pulmonary capillary wedge pressure was highest with the TALVV technique (17.2 ± 2.1 mmHg; P < 0.001) and was higher in the PBAS than in the IABP group; the difference was significant (9.6 ± 2.5 and 3.9 ± 1.3, respectively; P = 0.001). Reduction in central venous pressure with TALVV was highest with the other procedures (7.4 ± 1.1 mmHg; P < 0.001). However, procedure-related complications were significantly higher with TALVV compared to the PBAS and IABP groups (50% vs 17.6% and 10%, respectively; P = 0.015). We observed no significant differences in mortality or neurological complications between the groups. CONCLUSIONS Our results suggest that TALVV was the most effective method for LV unloading compared with PBAS and IABP for VA-ECMO support but was associated with complications. Efficient LV unloading may not improve survival.


Sign in / Sign up

Export Citation Format

Share Document