scholarly journals Prediction of Advisability of Returning Home Using the Home Care Score

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Akiyoshi Matsugi ◽  
Keisuke Tani ◽  
Yoshiki Tamaru ◽  
Nami Yoshioka ◽  
Akira Yamashita ◽  
...  

Purpose. The aim of this study was to assess whether the home care score (HCS), which was developed by the Ministry of Health and Welfare in Japan in 1992, is useful for the prediction of advisability of home care.Methods. Subjects living at home and in assisted-living facilities were analyzed. Binominal logistic regression analyses, using age, sex, the functional independence measure score, and the HCS, along with receiver operating characteristic curve analyses, were conducted.Findings/Conclusions. Only HCS was selected for the regression equation. Receiver operating characteristic curve analysis revealed that the area under the curve (0.9), sensitivity (0.82), specificity (0.83), and positive predictive value (0.84) for HCS were higher than those for the functional independence measure, indicating that the HCS is a powerful predictor for advisability of home care.Clinical Relevance. Comprehensive measurements of the condition of provided care and the activities of daily living of the subjects, which are included in the HCS, are required for the prediction of advisability of home care.

2016 ◽  
Vol 27 (8) ◽  
pp. 2264-2278 ◽  
Author(s):  
Liang Li ◽  
Tom Greene ◽  
Bo Hu

The time-dependent receiver operating characteristic curve is often used to study the diagnostic accuracy of a single continuous biomarker, measured at baseline, on the onset of a disease condition when the disease onset may occur at different times during the follow-up and hence may be right censored. Due to right censoring, the true disease onset status prior to the pre-specified time horizon may be unknown for some patients, which causes difficulty in calculating the time-dependent sensitivity and specificity. We propose to estimate the time-dependent sensitivity and specificity by weighting the censored data by the conditional probability of disease onset prior to the time horizon given the biomarker, the observed time to event, and the censoring indicator, with the weights calculated nonparametrically through a kernel regression on time to event. With this nonparametric weighting adjustment, we derive a novel, closed-form formula to calculate the area under the time-dependent receiver operating characteristic curve. We demonstrate through numerical study and theoretical arguments that the proposed method is insensitive to misspecification of the kernel bandwidth, produces unbiased and efficient estimators of time-dependent sensitivity and specificity, the area under the curve, and other estimands from the receiver operating characteristic curve, and outperforms several other published methods currently implemented in R packages.


2018 ◽  
Vol 6 (1) ◽  
pp. 440-447
Author(s):  
Kathare Alfred ◽  
Otieno Argwings ◽  
Kimeli Victor

The use of gold standard procedures in screening may be costly, risky or even unethical. It is, therefore, not admissible for large scale application. In this case, a more acceptable diagnostic predictor is applied to a sample of subjects alongside a gold standard procedure. The performance of the predictor is then evaluated using Receiver Operating Characteristic curve. The area under the curve, then, provides a summative measure of the performance of the predictor. The Receiver Operating Characteristic curve is a trade-off between sensitivity and specificity which in most cases are of different clinical significance. Also, the area under the curve is criticized for lack of coherent interpretation. In this study, we proposed the use of entropy as a summary index measure of uncertainty to compare diagnostic predictors. Noting that a diseased subject who is truly identified with the disease at a lower cut-off will also be identified at a higher cut-off, we substituted time variable in survival analysis for cut-offs in a binary predictor. We then derived the entropy of the functions of diagnostic predictors. Application of the procedure to real data showed that entropy was a strong measure for quantifying the amount of uncertainty engulfed in a set of cut-offs of binary diagnostic predictor.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Faik Orucoglu ◽  
Ebru Toker

Purpose. To assess and compare the anterior and posterior corneal surface parameters, keratoconus indices, thickness profile data, and data from enhanced elevation maps of keratoconic and normal corneas with the Pentacam Scheimpflug corneal tomography and to determine the sensitivity and specificity of these parameters in discriminating keratoconus from normal eyes.Methods. The study included 656 keratoconus eyes and 515 healthy eyes with a mean age of30.95±9.25and32.90±14.78years, respectively. Forty parameters obtained from the Pentacam tomography were assessed by the receiver operating characteristic curve analysis for their efficiency.Results. Receiver operating characteristic curve analyses showed excellent predictive accuracy (area under the curve, ranging from 0.914 to 0.972) for 21 of the 40 parameters evaluated. Among all parameters indices of vertical asymmetry, keratoconus index, front elevation at thinnest location, back elevation at thinnest location, Ambrósio Relational Thickness (ARTmax), deviation of average pachymetric progression, deviation of ARTmax, and total deviation showed excellent (>90%) sensitivity and specificity in addition to excellent area under the receiver operating characteristic curve (AUROC).Conclusions. Parameters derived from the topometric and Belin-Ambrósio enhanced ectasia display maps very effectively discriminate keratoconus from normal corneas with excellent sensitivity and specificity.


2019 ◽  
Vol 30 (7-8) ◽  
pp. 221-228
Author(s):  
Shahab Hajibandeh ◽  
Shahin Hajibandeh ◽  
Nicholas Hobbs ◽  
Jigar Shah ◽  
Matthew Harris ◽  
...  

Aims To investigate whether an intraperitoneal contamination index (ICI) derived from combined preoperative levels of C-reactive protein, lactate, neutrophils, lymphocytes and albumin could predict the extent of intraperitoneal contamination in patients with acute abdominal pathology. Methods Patients aged over 18 who underwent emergency laparotomy for acute abdominal pathology between January 2014 and October 2018 were randomly divided into primary and validation cohorts. The proposed intraperitoneal contamination index was calculated for each patient in each cohort. Receiver operating characteristic curve analysis was performed to determine discrimination of the index and cut-off values of preoperative intraperitoneal contamination index that could predict the extent of intraperitoneal contamination. Results Overall, 468 patients were included in this study; 234 in the primary cohort and 234 in the validation cohort. The analyses identified intraperitoneal contamination index of 24.77 and 24.32 as cut-off values for purulent contamination in the primary cohort (area under the curve (AUC): 0.73, P < 0.0001; sensitivity: 84%, specificity: 60%) and validation cohort (AUC: 0.83, P < 0.0001; sensitivity: 91%, specificity: 69%), respectively. Receiver operating characteristic curve analysis also identified intraperitoneal contamination index of 33.70 and 33.41 as cut-off values for feculent contamination in the primary cohort (AUC: 0.78, P < 0.0001; sensitivity: 87%, specificity: 64%) and validation cohort (AUC: 0.79, P < 0.0001; sensitivity: 86%, specificity: 73%), respectively. Conclusions As a predictive measure which is derived purely from biomarkers, intraperitoneal contamination index may be accurate enough to predict the extent of intraperitoneal contamination in patients with acute abdominal pathology and to facilitate decision-making together with clinical and radiological findings.


2021 ◽  
pp. 096228022199595
Author(s):  
Yalda Zarnegarnia ◽  
Shari Messinger

Receiver operating characteristic curves are widely used in medical research to illustrate biomarker performance in binary classification, particularly with respect to disease or health status. Study designs that include related subjects, such as siblings, usually have common environmental or genetic factors giving rise to correlated biomarker data. The design could be used to improve detection of biomarkers informative of increased risk, allowing initiation of treatment to stop or slow disease progression. Available methods for receiver operating characteristic construction do not take advantage of correlation inherent in this design to improve biomarker performance. This paper will briefly review some developed methods for receiver operating characteristic curve estimation in settings with correlated data from case–control designs and will discuss the limitations of current methods for analyzing correlated familial paired data. An alternative approach using conditional receiver operating characteristic curves will be demonstrated. The proposed approach will use information about correlation among biomarker values, producing conditional receiver operating characteristic curves that evaluate the ability of a biomarker to discriminate between affected and unaffected subjects in a familial paired design.


Sign in / Sign up

Export Citation Format

Share Document