scholarly journals Modeling and Simulation of Power Distribution System in More Electric Aircraft

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Zhangang Yang ◽  
Junchao Qu ◽  
Yingchuan Ma ◽  
Xudong Shi

The More Electric Aircraft concept is a fast-developing trend in modern aircraft industry. With this new concept, the performance of the aircraft can be further optimized and meanwhile the operating and maintenance cost will be decreased effectively. In order to optimize the power system integrity and have the ability to investigate the performance of the overall system in any possible situations, one accurate simulation model of the aircraft power system will be very helpful and necessary. This paper mainly introduces a method to build a simulation model for the power distribution system, which is based on detailed component models. The power distribution system model consists of power generation unit, transformer rectifier unit, DC-DC converter unit, and DC-AC inverter unit. In order to optimize the performance of the power distribution system and improve the quality of the distributed power, a feedback control network is designed based on the characteristics of the power distribution system. The simulation result indicates that this new simulation model is well designed and it works accurately. Moreover, steady state performance and transient state performance of the model can fulfill the requirements of aircraft power distribution system in the realistic application.

2013 ◽  
Vol 748 ◽  
pp. 449-452
Author(s):  
Wei Jin ◽  
Kuang Shi ◽  
Jun Hao Li

Ferromagnetic resonance overvoltage is an internal overvoltage and it often occurred in the power distribution system which neutral point ungrounded. A 35kV power system is used as the prototype to establish the 35 kV substation's simulation model which is based on the ATP - EMTP and ferromagnetic resonance overvoltage is researched and analyzed In this paper. The ferromagnetic resonance overvoltage which is stimulated by single-phase ground fault is studied in this paper studied and ferromagnetic resonance suppression methods were also studied. The results show that the nonlinear resistor is connected in the PT primary neutral side and small resistance is connected in the PT open delta are effectively methods which can restrain ferromagnetic resonance overvoltage.


2019 ◽  
Vol 34 (4) ◽  
pp. 3937-3947 ◽  
Author(s):  
Sandro Gunter ◽  
Giampaolo Buticchi ◽  
Giovanni De Carne ◽  
Chunyang Gu ◽  
Marco Liserre ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document