scholarly journals Long-Term In Vivo Evaluation of Chitosan Nerve Guide Properties with respect to Two Different Sterilization Methods

2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Maria Stößel ◽  
Jennifer Metzen ◽  
Vivien M. Wildhagen ◽  
Olaf Helmecke ◽  
Lena Rehra ◽  
...  

Severe peripheral nerve injuries are reconstructed either with autologous nerve grafts (gold standard) or alternatively with clinically approved artificial nerve guides. The most common method used to sterilize these medical products is ethylene oxide gassing (EO). However, this method has several disadvantages. An alternative, which has been barely studied so far, represents beta irradiation (β). In previous studies, we developed an artificial nerve guide made of chitosan (chitosan nerve guide, CNG), a biomaterial that is known to potentially retain toxic residues upon EO sterilization. Therefore, we analyzed the long-term regeneration-supporting and mechanical properties of CNGs upon their sterilization with EO or β and their following application in unilateral repair of 12 mm gaps of the rat sciatic nerve. Over a period of 76 weeks, we serially evaluated the recovery of motor functions, the possible emergence of an inflammation in the surrounding connective tissue, the regrowth of axons into the distal nerve, and possible changes in the material properties. Our first long-term evaluation did not reveal significant differences between both sterilization methods. Thus, β is as appropriate as commonly used EO for sterilization of CNGs; however, it may slightly increase the stiffness of the biomaterial over time.

Pharmaceutics ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1210
Author(s):  
Xieguo Yan ◽  
Shiqiang Wang ◽  
Kaoxiang Sun

Schizophrenia, a psychiatric disorder, requires long-term treatment; however, large fluctuations in blood drug concentration increase the risk of adverse reactions. We prepared a long-term risperidone (RIS) implantation system that can stabilize RIS release and established in-vitro and in-vivo evaluation systems. Cumulative release, drug loading, and entrapment efficiency were used as evaluation indicators to evaluate the effects of different pore formers, polymer ratios, porogen concentrations, and oil–water ratios on a RIS implant (RIS-IM). We also built a mathematical model to identify the optimized formulation by stepwise regression. We also assessed the crystalline changes, residual solvents, solubility and stability after sterilization, in-vivo polymer degradation, pharmacokinetics, and tissue inflammation in the case of the optimized formulation. The surface of the optimized RIS microspheres was small and hollow with 134.4 ± 3.5 µm particle size, 1.60 SPAN, 46.7% ± 2.3% implant drug loading, and 93.4% entrapment efficiency. The in-vitro dissolution behavior of RIS-IM had zero-order kinetics and stable blood concentration; no lag time was released for over three months. Furthermore, the RIS-IM was not only non-irritating to tissues but also had good biocompatibility and product stability. Long-acting RIS-IMs with microspheres and film coatings can provide a new avenue for treating schizophrenia.


2021 ◽  
pp. 100172
Author(s):  
Chen Lai ◽  
Shu-Jiang Zhang ◽  
Xuan-Chen Chen ◽  
Li-Yuan Sheng ◽  
Tian-Wei Qi ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Eduardo Romero ◽  
Alfonso Martínez ◽  
Marta Oteo ◽  
Marta Ibañez ◽  
Mirentxu Santos ◽  
...  

AbstractRadionuclide generator systems can routinely provide radionuclides on demand such as 68Ga produced by a 68Ge/68Ga generator without the availability of an on-site accelerator or a research reactor. Thus, in this work nano-SnO2 was used to develop a new 68Ge/68Ga generator which was evaluated over a period of 17 months and 305 elution cycles. The elution yield was 91.1 ± 1.8% in the first 7 mL (1 M HCl as eluent) when the generator was new and then it decreased with time and use to 73.8 ± 1.9%. Around 80% of the elutable 68Ga activity was obtained in 1 mL and the 68Ge content in the eluate did not exceed 1 × 10–4% over the investigation period when it was eluted regularly. The described generator provided adequate results for radiolabelling of DOTA-TOC with direct use of eluate. In addition, [68Ga]Ga-DOTA-TOC was tested satisfactorily for in vivo tumor detection by microPET/CT imaging in a lung cancer mouse model.


ASAIO Journal ◽  
1996 ◽  
Vol 42 (2) ◽  
pp. 38
Author(s):  
Y. Wakisaka ◽  
Y. Taenaka ◽  
E. Tatsumi ◽  
T. Nishimura ◽  
T. Masuzawa ◽  
...  

Neuroscience ◽  
2011 ◽  
Vol 181 ◽  
pp. 278-291 ◽  
Author(s):  
P.G. di Summa ◽  
D.F. Kalbermatten ◽  
E. Pralong ◽  
W. Raffoul ◽  
P.J. Kingham ◽  
...  

2017 ◽  
Vol 13 (3) ◽  
pp. 272-279 ◽  
Author(s):  
Athanasios Peppas ◽  
Ariel Furer ◽  
Jon Wilson ◽  
GengHua Yi ◽  
Yanping Cheng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document