scholarly journals Electrodeposition of 4-Benzenesulfonic Acid onto a Graphite-Epoxy Composite Electrode for the Enhanced Voltammetric Determination of Caffeine in Beverages

2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Leonardo de A. Furtado ◽  
Mariana C. de O. Gonçalves ◽  
Carlos V. M. Inocêncio ◽  
Edilson M. Pinto ◽  
Daniela de L. Martins ◽  
...  

Caffeine is widely present in food and drinks, such as teas and coffees, being also part of some currently commercialized medicines, but despite its enhancement on several functions of human body, its exceeding use can promote many health problems. In order to develop new fast approaches for the caffeine sensing, graphite-epoxy composite electrodes (GECE) were used as substrate, being modified by different diazonium salts, synthetized as their tetraflouroborate salts. An analytical method for caffeine quantification was developed, using sware wave voltammetry (SWV) in Britton–Robinson buffer pH 2.0. Detection limits for bare electrode and 4-benzenesulfonic modified electrode were observed circa 145 µmol·L−1 and 1.3 µmol·L−1, respectively. The results have shown that the modification shifts the oxidation peaks to lower potential. Kinetics of the reaction limited by diffusion was more expressive when caffeine was added to the solution, resulting in decreases of impedance, characterized by lower Rct. All results for caffeine determination were compared to a reference chromatographic procedure (HPLC), showing no statistical difference. Analytical parameters for validation were suitably determined according to local legislation, leading to a linear behaviour from 5 to 150 µmol·L−1; precision of 4.09% was evaluated based on the RDC 166/17, and accuracy was evaluated in comparison with the reference method, with recovery of 98.37 ± 2.58%.

2012 ◽  
Vol 48 (4) ◽  
pp. 639-649 ◽  
Author(s):  
Kellen Heloizy Garcia Freitas ◽  
Orlando Fatibello-Filho ◽  
Ivanildo Luiz de Mattos

A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) for the determination of rutin in pharmaceutical samples by square-wave voltammetry is described herein. The modified electrode allows the determination of rutin at a potential (0.20 V vs. Ag/AgCl (3.0 mol L-1 KCl)) lower than that observed at an unmodified electrode. The peak current was found to be linear to the rutin concentration in the range from 9.9 × 10-8 to 2.5 × 10-6 mol L-1, with a detection limit of 1.2×10-8 mol L-1. The response of the electrode was stable, with no variation in baseline levels within several hours of continuous operation. The surface morphology of the modified electrode was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) system. The results obtained are precise and accurate. In addition, these results are in agreement with those obtained by the chromatographic method at a 95% confidence level.


Author(s):  
Abel Ibrahim Balbin Tamayo ◽  
Leodanis Correa Fajardo ◽  
Ana Margarita Esteva Guas

Graphite-epoxy composites (GECs) are alternative construction materials for electro­chemical sensors. For these materials, the electron transfer rate constant of some redox reaction depends additionally on the stoichiometric relationship between the insulating and conducting phases of the composite. In this work, the influence of dif­fe­rent ratios of araldite/hardener/graphite on the electrochemical properties of GEC electrodes is evaluated for the simultaneous determination of adenine and guanine in the single chain DNA, using the square wave voltammetry technique. Six GEC electro­des were prepared with different ratios of components, and electrochemically charac­terized by cyclic voltammetry in the presence of ferri/ferrocyanide redox couple as a redox probe. GEC electrodes that showed the best electrochemical responses of redox probe were characterized by thermogravimetric analysis (TGA) and used for the simul­taneous determination of free adenine and guanine in a solution, and DNA oligonu­cle­otides. The best results were obtained for GEC electrodes containing twice higher volu­me of araldite resin with respect to the hardener. TGA analysis revealed presence of 15-26 % of resin for these GEC electrodes. The obtained results revealed potential appl­ication of these GEC electrodes as DNA sensors based on the oxidation signal of guanine.


2006 ◽  
Vol 31 (4) ◽  
pp. 59-62 ◽  
Author(s):  
P. Cervini ◽  
E.T.G. Cavalheiro

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.


2014 ◽  
Vol 6 (13) ◽  
pp. 4775-4782 ◽  
Author(s):  
M. Ardelean ◽  
F. Manea ◽  
N. Vaszilcsin ◽  
R. Pode

Detection results obtained for sulphide detection in real water using a CNF electrode by square-wave voltammetry.


2008 ◽  
Vol 20 (15) ◽  
pp. 1719-1722 ◽  
Author(s):  
Florica Manea ◽  
Ciprian Radovan ◽  
Ioana Corb ◽  
Aniela Pop ◽  
Georgeta Burtica ◽  
...  

2020 ◽  
Vol 159 ◽  
pp. 105485
Author(s):  
Gláucia Tinoco Corrêa ◽  
João Carlos de Souza ◽  
João Pedro Silva ◽  
Maria Isabel Pividori ◽  
Maria Valnice Boldrin Zanoni

Sign in / Sign up

Export Citation Format

Share Document