Simultaneous Determination of 4-Chlorophenol and Oxalic Acid Using an Expanded Graphite-Epoxy Composite Electrode

2008 ◽  
Vol 20 (15) ◽  
pp. 1719-1722 ◽  
Author(s):  
Florica Manea ◽  
Ciprian Radovan ◽  
Ioana Corb ◽  
Aniela Pop ◽  
Georgeta Burtica ◽  
...  
2015 ◽  
Vol 98 (3) ◽  
pp. 817-821 ◽  
Author(s):  
Wenchang Wang ◽  
Ye Chen ◽  
Jing Zhang ◽  
Xue Wang ◽  
Zhidong Chen

Abstract A sensitive electrochemical method was developed for the simultaneous determination of Brilliant Blue (BB) and tartrazine (Tz) using an ionic liquid-modified expanded graphite paste electrode (IL-EGPE). The IL-EGPE was prepared by mixing ionic liquid-expanded graphite composite (IL-EG) with solid paraffin. Compared with the EGPE, the IL-EGPE remarkably enhanced the electrocatalytic oxidation signals of BB and Tz. Under optimal experimental conditions, the designed IL-EGPE exhibited wide linear responses to BB and Tz ranging from 5.0 × 10–9 to 4.0 × 10–6 M and 1.0 × 10–8 to 1.0 × 10–6 M, respectively. The detection limits for BB and Tz were 2.0 × 10–9 M (1.6 ng/mL) and 3.3 × 10–9 M (1.8 ng/mL) at an S/N of 3, respectively. This electrode showed good reproducibility, stability, and reusability. The proposed method was successfully applied in the simultaneous determination of BB and Tz in a soft drink with satisfactory results.


2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Leonardo de A. Furtado ◽  
Mariana C. de O. Gonçalves ◽  
Carlos V. M. Inocêncio ◽  
Edilson M. Pinto ◽  
Daniela de L. Martins ◽  
...  

Caffeine is widely present in food and drinks, such as teas and coffees, being also part of some currently commercialized medicines, but despite its enhancement on several functions of human body, its exceeding use can promote many health problems. In order to develop new fast approaches for the caffeine sensing, graphite-epoxy composite electrodes (GECE) were used as substrate, being modified by different diazonium salts, synthetized as their tetraflouroborate salts. An analytical method for caffeine quantification was developed, using sware wave voltammetry (SWV) in Britton–Robinson buffer pH 2.0. Detection limits for bare electrode and 4-benzenesulfonic modified electrode were observed circa 145 µmol·L−1 and 1.3 µmol·L−1, respectively. The results have shown that the modification shifts the oxidation peaks to lower potential. Kinetics of the reaction limited by diffusion was more expressive when caffeine was added to the solution, resulting in decreases of impedance, characterized by lower Rct. All results for caffeine determination were compared to a reference chromatographic procedure (HPLC), showing no statistical difference. Analytical parameters for validation were suitably determined according to local legislation, leading to a linear behaviour from 5 to 150 µmol·L−1; precision of 4.09% was evaluated based on the RDC 166/17, and accuracy was evaluated in comparison with the reference method, with recovery of 98.37 ± 2.58%.


2007 ◽  
Vol 19 (9) ◽  
pp. 973-977 ◽  
Author(s):  
Manuel Cano ◽  
Beatriz Palenzuela ◽  
J. Luis Ávila ◽  
Rafael Rodríguez-Amaro

2011 ◽  
Vol 3 (1) ◽  
pp. 7-12 ◽  
Author(s):  
S. Motoc ◽  
F. Manea ◽  
A. Pop ◽  
R. Pode ◽  
G. Burtica

Sensors ◽  
2007 ◽  
Vol 7 (4) ◽  
pp. 615-627 ◽  
Author(s):  
Florica Manea ◽  
Ciprian Radovan ◽  
Ioana Corb ◽  
Aniela Pop ◽  
Georgeta Burtica ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document