scholarly journals To Win the Battle, First Know Your Enemy: Error Rates in Immunohematology External Quality Assessment Results

2019 ◽  
Vol 47 (1) ◽  
pp. 80-87 ◽  
Author(s):  
Christoph Buchta ◽  
Wim Coucke ◽  
Wolfgang R. Mayr ◽  
Mathias M. Müller ◽  
Günther F. Körmöczi
2019 ◽  
Vol 44 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Ferzane Mercan ◽  
Muhittin A. Serdar ◽  
Mehmet Senes ◽  
Dildar Konukoglu ◽  
Tamer Cevat İnal ◽  
...  

Abstract Objective Medical laboratories encounter critical obstacles in External Quality Assessment (EQA) practices that are key to assessment of the analytical period. Present study aims to unveil the challenges in nationwide inter-laboratory harmonization and suggest practical solutions. Materials and methods EQA results of 1941 laboratories participating in 18 different EQA-programs between 2010 and 2017 were examined. Standard Deviation Index (SDI) of each program calculated using 801,028 sample data from 24 different clinical chemical tests were used to conduct a process assessment. Results There is a significant discrepancy in unsatisfactory performance ratio among different EAQ-programs with an average of 3.4% (27,074 cases) between 2010 and 2017 and a decreasing trend (~40–50%) in 7-years. Programs with higher SDI display lower discrepancy rates. Reasons for unaccepted results appear to be data entry errors (8.27–22.2%), material dilution errors (5–11.4%), technical problems (3.76–7.9%); while random or unidentified causes account for a major of 44.9–59.5%. In 7-years, 15.7% reduction was observed in average SDI of all tests. Conclusion With the launch of national EQA follow-up program, increased awareness of the analytical processes led to a decrease in unaccepted results and variances in the analytical period. Staff training is suggested as a significant measure. In addition, simultaneous assessment of SDI and allowable total error rates would reduce the variation between programs.


2009 ◽  
Vol 46 ◽  
pp. S36
Author(s):  
A.A. Sayiner ◽  
N. Esen ◽  
O.A. Ozbek ◽  
B. Nalca ◽  
C. Scott ◽  
...  

2011 ◽  
Vol 49 (12) ◽  
pp. 4356-4360 ◽  
Author(s):  
L. E. Scott ◽  
N. Gous ◽  
B. E. Cunningham ◽  
B. D. Kana ◽  
O. Perovic ◽  
...  

2011 ◽  
Vol 412 (11-12) ◽  
pp. 1127-1132 ◽  
Author(s):  
Jin-Sook Wang ◽  
Mee-Kyung Kee ◽  
Byeong-Sun Choi ◽  
Chan-Wha Kim ◽  
Sung Soon Kim

2005 ◽  
Vol 51 (9) ◽  
pp. 1632-1636 ◽  
Author(s):  
Gunn BB Kristensen ◽  
Nina Gade Christensen ◽  
Geir Thue ◽  
Sverre Sandberg

Abstract Background: External quality assessment schemes (EQAS) are conducted to evaluate user performance (participant assessment) and to assess different methods and instruments (method assessment). The quality of control materials is crucial to achieving these goals. Inconsistencies in between-lot variations detected by use of different control and sample materials may affect EQAS outcomes. Methods: For the Accu-Chek Sensor, Precision Xtra, Ascensia Elite, and HemoCue 201 glucometers, 3 different lots of glucose strips were used with each instrument. Method assessment results from analysis of capillary blood and 3 control materials were used to calculate between-lot differences. A simulation study was performed to evaluate the effect of between-lot variation on participant assessment results. Results: With the Precision Xtra, the results obtained with EQA control material mirrored those obtained with capillary blood, but for the other instruments, we found between-lot differences of as much as 1.3 mmol/L, which were substantially greater than those found with capillary blood and of clinical importance at decision limits. The simulation study showed an effect on participant assessment results related to the target values, with the percentage of poor results decreasing (38%, 10%, and 4%) with the use of common, method-specific, and lot-specific target values, respectively. Conclusions: Between-lot variation may influence participant EQA results for participant and method assessments. The clinical relevance of between-lot variation discovered in EQAS using noncommutable control materials should be examined by use of native blood samples.


2018 ◽  
Vol 56 (12) ◽  
pp. 2039-2046 ◽  
Author(s):  
Christoph Buchta ◽  
Wim Coucke ◽  
Wolfgang R. Mayr ◽  
Mathias M. Müller ◽  
Reinhard Oeser ◽  
...  

Abstract Background ISO 9001 and ISO 15189 have been established as continuative models for quality systems beyond national laws, mandatory standards and guidelines of expert associations regarding analytical and organisational performance of medical laboratories and transfusion services. Although widely used, their impact on laboratory performance has not been investigated. Methods We retrospectively analysed the results of 167 laboratories in 59 distributions of the Austrian red cell immunohaematology external quality assessment (EQA) scheme in the years 1999–2017. The performance for each parameter and trends of individual participants were compared with respect to certification or accreditation status of participants’ quality systems and to laboratory type. Results Considering more than 52,000 EQA results, the absence or presence of a laboratory quality management system showed different error rates. Laboratories with ISO 9001 or ISO 15189 certification/accreditation had 0.7% incorrect results, while this rate was doubled without such quality systems (1.4%, p=0.0002). Statistically significant error reductions were seen upon ISO 9001/ISO 15189 implementation (1.3% before vs. 0.7% after; p=0.0468). Transfusion services had fewer errors (0.9%) compared to hospital and independent laboratories (both 1.2%). Conclusions Implementation and maintenance of quality systems according to ISO 9001 or ISO 15189 as well as laboratory specialisation result in better analytical performance as can be seen in immunohaematology EQA results. The conclusion is that these results apply to other laboratory tests and perhaps to other areas of health care.


Sign in / Sign up

Export Citation Format

Share Document