scholarly journals Loss Minimization of Power Distribution Network using Different Types of Distributed Generation Unit

Author(s):  
Su Hlaing Win ◽  
Pyone Lai Swe

A Radial Distribution network is important in power system area because of its simple design and reduced cost. Reduction of system losses and improvement of voltage profile is one of the key aspects in power system operation. Distributed generators are beneficial in reducing losses effectively in distribution systems as compared to other methods of loss reduction. Sizing and location of DG sources places an important role in reducing losses in distribution network. Four types of DG are considered in this paper with one DG installed for minimize the total real and reactive power losses. The objective of this methodology is to calculate size and to identify the corresponding optimum location for DG placement for minimizing the total real and reactive power losses and to improve voltage profile   in primary distribution system. It can obtain maximum loss reduction for each of four types of optimally placed DGs. Optimal sizing of Distributed Generation can be calculated using exact loss formula and an efficient approach is used to determine the optimum location for Distributed Generation Placement.  To demonstrate the performance of the proposed approach 36-bus radial distribution system in Belin Substation in Myanmar was tested and validated with different sizes and the result was discussed.

Author(s):  
Su Mon Myint ◽  
Soe Win Naing

Nowadays, the electricity demand is increasing day by day and hence it is very important not only to extract electrical energy from all possible new power resources but also to reduce power losses to an acceptable minimum level in the existing distribution networks where a large amount of power dissipation occurred. In Myanmar, a lot of power is remarkably dissipated in distribution system.  Among methods in reducing power losses, network reconfiguration method is employed for loss minimization and exhaustive technique is also applied to achieve the minimal loss switching scheme. Network reconfiguration in distribution systems is performed by opening sectionalizing switches and closing tie switches of the network for loss reduction and voltage profile improvement. The distribution network for existing and reconfiguration conditions are modelled and simulated by Electrical Transient Analyzer Program (ETAP) 7.5 version software. The inputs are given based on the real time data collected from 33/11kV substations under Yangon Electricity Supply Board (YESB). The proposed method is tested on 110-Bus, overhead AC radial distribution network of Dagon Seikkan Township since it is long-length, overloaded lines and high level of power dissipation is occurred in this system. According to simulation results of load flow analysis, voltage profile enhancement and power loss reduction for proposed system are revealed in this paper.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Sanjay Jain ◽  
Ganga Agnihotri ◽  
Shilpa Kalambe ◽  
Renuka Kamdar

This paper intends to enumerate the impact of distributed generation (DG) on distribution system in terms of active as well as reactive power loss reduction and improved voltage stability. The novelty of the method proposed in this paper is the simple and effective way of sizing and siting of DG in a distribution system by using two-port Z-bus parameters. The validity of the method is verified by comparing the results with already published methods. Comparative study presented has shown that the proposed method leads existing methods in terms of its simplicity, undemanding calculation procedures, and less computational efforts and so does the time. The method is implemented on IEEE 69-bus test radial distribution system and results show significant reduction in distribution power losses with improved voltage profile of the system. Simulation is carried out in MATLAB environment for execution of the proposed algorithm.


2019 ◽  
Vol 4 (10) ◽  
pp. 18-23 ◽  
Author(s):  
Abubakar Bawa ◽  
Muhammad Uthman ◽  
Farouq E. Shaibu ◽  
Koledowo Saliu Oyewale

The Point of Common Coupling (PCC) where suppliers’ responsibility and customers demand meet is of great concern due to increase degree of voltage variation assessment; valuable indicator of system conditions (voltage profile). Unstable condition of the power system outside operational or statutory limit, an adverse effect of nonlinear loads usually generate harmonics as well as fundamental frequency voltage variations and increase rate of power losses. These loads need to be compensated for. The major concerns of utility operations is to mitigate adverse effect of this system conditions. This research work focuses on optimal siting and sizing of Distributed Generation (DG) in a 43 bus distribution system. Power losses coupled with voltage deviation, considering objective function that compute present percentage losses in 11kV Dikko feeder, Abuja Electricity Distribution Company (AEDC), Suleja Distribution Network, Nigeria. We identified buses with poor voltage profile without DG installation and determined optimal sizing and siting of DGs where losses can be mitigated and power quality improved. ETAP version 12.6 2014 was used for load flow analysis to establish a decisive based case. The total load of the system considered was (3490 + j2700) kVA. Active and Reactive power losses in the system before DG installation were 246.300 kW and 289.903 kVAR respectively. DGs installation in the case study, has a considerable effects on loss reduction in the network. It is observed that 8.10% and 7.20% active and reactive power loss reduction was achieved while bus voltage improved by 0.4%. Genetic Algorithm Optimization techniques programmed in MATLAB 2015 software was used for optimal placement and sizing of the DG in the system.


Distributed generation system penetration in the existing distribution system is done for minimizing the losses and improving the voltage profile. There are total five types of distributed generation systems exist based on their power delivery like distributed generation system injecting real and reactive power, supplying real power only, supplying reactive power only, absorbing reactive power only , supplying real power and absorbing reactive power. All these five types of distributed generation systems have different penetration effects on the radial distribution system. We get different voltage profiles and power losses for different types of distributed generation systems. The testing of these five types of distributed generation systems will be done on IEEE 33 bus radial distribution system. For computing, the line parameters and power losses of the above testing system the forward-backward sweep load flow method will be applied


Author(s):  
Mahesh Kumar ◽  
Perumal Nallagownden ◽  
Irraivan Elamvazuthi ◽  
Pandian Vasant ◽  
Luqman Hakim Rahman

In the distribution system, distributed generation (DG) are getting more important because of the electricity demands, fossil fuel depletion and environment concerns. The placement and sizing of DGs have greatly impact on the voltage stability and losses in the distribution network. In this chapter, a particle swarm optimization (PSO) algorithm has been proposed for optimal placement and sizing of DG to improve voltage stability index in the radial distribution system. The two i.e. active power and combination of active and reactive power types of DGs are proposed to realize the effect of DG integration. A specific analysis has been applied on IEEE 33 bus system radial distribution networks using MATLAB 2015a software.


Author(s):  
Arvind Raj ◽  
Nur Fadilah Ab Aziz ◽  
Zuhaila Mat Yasin ◽  
Nur Ashida Salim

Voltage instability in power distribution systems can result in voltage collapse throughout the grid. Today, with the advanced of power generation technology from renewable sources, concerns of utility companies are much being focused on the stability of the grid when there is an integration of distributed generation (DG) in the system.  This paper presents a study on DG units placement and sizing in a radial distribution network by using a pre-developed index called Voltage Stability Condition Index (VSCI). In this paper, VSCI is used to determine DG placement candidates, while the value of power losses is used to identify the best DG placement. The proposed method is tested on a standard 33-bus radial distribution network and compared with existing Ettehadi and Aman methods. The effectiveness of the method is presented in terms of reduction in power system losses, maximization of system loadability and voltage quality improvement. Results show that VSCI can be utilized as the voltage stability indicator for DG placement in radial distribution power system. The integration of DG is found to improve voltage stability by increasing the system loadability and reducing the power losses of the network.


2013 ◽  
Vol 768 ◽  
pp. 371-377 ◽  
Author(s):  
E. Rekha ◽  
D. Sattianadan ◽  
M. Sudhakaran

Distributed generators (DG) are much beneficial in reducing the losses effectively compared to other methods of loss reduction. It is expected to become more important in future generation. This paper deals with the multi DGs placement in radial distribution system to reduce the system power loss and improve the voltage profile by using the optimization technique of particle swarm optimization (PSO). The PSO provides a population-based search procedure in which individuals called particles change their positions with time. Initially, the algorithm randomly generates the particle positions representing the size and location of DG. The proposed PSO algorithm is used to determine optimal sizes and locations of multi-DGs. The objective function is the combination of real, reactive power loss and voltage profile with consideration of weights and impact indices with and without DG. Test results indicate that PSO method can obtain better results on loss reduction and voltage profile improvement than the simple heuristic search method on the IEEE33-bus and IEEE 90-bus radial distribution systems.


Author(s):  
Suyanto Suyanto ◽  
Citra Rahmadhani ◽  
Ontoseno Penangsang ◽  
Adi Soeprijanto

<p>Unbalanced three-phase radial distribution system has a complex problem in power system. It has many branches and it is sometimes voltage profile’s not stable at every end branches. For improvement of voltage profile, it can be performed by penetrating of a distributed generation models. Information of voltage profile can be gained by study of power flow.  The Modified Backward-Forward is one of the most widely used methods of development of power flow and has been extensively used for voltage profile analysis. In this paper, a study of power flow based on the Modified Backward-Forward method was used to capture the complexities of unbalanced three phase radial distribution system in the 20 kV distribution network in North Surabaya city, East Java, Indonesia within considering distributed generation models. In summary, for the informants in this study, the Modified Backward-Forward method has had quickly convergence and it’s just needed 3 to 5 iteration of power flow simulation which’s compared to other power flow development methods. Distributed Generation models in the modified the modified 34 BUS IEEE system and 20 kV distribution network has gained voltage profile value on limited range. One of the more significant findings to emerge from this development is that the Modified Backward-Forward method has average of error voltage about 0.0017 % to 0.1749%.</p>


2022 ◽  
Vol 2022 ◽  
pp. 1-14
Author(s):  
Muhammad Aamir Aman ◽  
Xin Cheng Ren ◽  
Wajahat Ullah Khan Tareen ◽  
Muhammad Abbas Khan ◽  
Muhammad Rizwan Anjum ◽  
...  

Many underdeveloped countries are facing acute shortage of electric power and short term measures are important to consider to address the problems of power outage, power plant failures, and disaster areas. Distributed generation (DG) is a promising approach for such cases as it allows quick on-site installation and generation of electric power. Injection of DG can improve the system voltage profile and also reduce the system's total power losses. However, the placement and sizing of the DG unit is an optimization problem in the radial distribution system. As a test case, this study examines voltage profile improvement and system power losses for an 11 KV residential feeder at the Abdul Rehman Baba grid station in Pakistan, which is modelled using the Electrical Transient Analyzer Program (ETAP). For various scenarios, several tests are conducted to assess the effects of DG on the distribution system. The results show that proper design considerations of size and location of a DG, to be inserted in to the system, lead to significant reduction in power losses and improvement in voltage profile and thus improvement in the overall efficiency of the power system. The projections of this work can be used to optimize the expansion of a power system and tackling different issues related to voltage profile in distribution sector worldwide.


2012 ◽  
Vol 1 (2) ◽  
pp. 56 ◽  
Author(s):  
M. Rostamzadeh ◽  
K. Valipour ◽  
S. J. Shenava ◽  
M. Khalilpour ◽  
N. Razmjooy

This paper proposes an Imperialist Competitive Algorithm (ICA) for optimal multiple distributed generations (DGs) placement and sizing in a distribution system. The objective is to minimize the total real power losses and improve the voltage profile within real and reactive power generation and voltage limits. Three types of DG are considered and the ICA is used to find the better sizes and locations of DGs for maximum real power losses reduction and voltage improvement for given number of DG units in each type. Both integer and continuous variables are considered in ICA, integer variable for locations and continues variable for sizes. The total real power losses and voltage profile evaluation are based on a power flow method for radial distribution system with the representation of DGs. The proposed method has been demonstrated on 33 bus radial distribution system. The efficiency of the ICA in reducing the total power losses and improving voltage is validated by comparing the obtained results with Particle Swarm Optimization (PSO) algorithm.