scholarly journals Elevated Left and Right Atrial Pressures Long‐Term After Atrial Septal Defect Correction: An Invasive Exercise Hemodynamic Study

Author(s):  
Zarmiga Karunanithi ◽  
Mads Jønsson Andersen ◽  
Søren Mellemkjær ◽  
Mathias Alstrup ◽  
Farhad Waziri ◽  
...  

Background Despite correction of the atrial septal defect (ASD), patients experience atrial fibrillation frequently and have increased morbidity and mortality. We examined physical capacity, cardiac performance, and invasive hemodynamics in patients with corrected ASD. Methods and Results Thirty‐eight corrected patients with isolated secundum ASD and 19 age‐matched healthy controls underwent right heart catheterization at rest and during exercise with simultaneous expired gas assessment and echocardiography. Maximum oxygen uptake was comparable between groups (ASD 32.7±7.7 mL O 2 /kg per minute, controls 35.2±7.5 mL O 2 /kg per minute, P =0.3), as was cardiac index at both rest and peak exercise. In contrast, pulmonary artery wedge v wave pressures were increased at rest and peak exercise (rest: ASD 14±4 mm Hg, controls 10±5 mm Hg, P =0.01; peak: ASD 25±9 mm Hg, controls 14±9 mm Hg, P =0.0001). The right atrial v wave pressures were increased at rest but not at peak exercise. The transmural filling pressure gradient (TMFP) was higher at peak exercise among patients with ASD (10±6 mm Hg, controls 7±3 mm Hg, P =0.03). One third of patients with ASD demonstrated an abnormal hemodynamic exercise response defined as mean pulmonary artery wedge pressure ≥25 mm Hg and/or mean pulmonary artery pressure ≥35 mm Hg at peak exercise. These patients had significantly elevated peak right and left atrial a wave pressures, right atrial v wave pressures, pulmonary artery wedge v wave pressures, and transmural filling pressure compared with both controls and patients with ASD with a normal exercise response. Conclusions Patients with corrected ASD present with elevated right and in particular left atrial pressures at rest and during exercise despite preserved peak exercise capacity. Abnormal atrial compliance and systolic atrial function could predispose to the increased long‐term risk of atrial fibrillation. Registration Information clinicaltrials.gov. Identifier: NCT03565471.

2020 ◽  
pp. 1-2
Author(s):  
Uma Devi Karuru ◽  
Saurabh Kumar Gupta

Abstract It is not uncommon to have prolapse of the atrial septal occluder device despite accurate measurement of atrial septal defect and an appropriately chosen device. This is particularly a problem in cases with large atrial septal defect with absent aortic rim. Various techniques have been described for successful implantation of atrial septal occluder in such a scenario. The essence of all these techniques is to prevent prolapse of the left atrial disc through the defect while the right atrial disc is being deployed. In this brief report, we illustrate the use of cobra head deformity of the device to successfully deploy the device across the atrial septum.


2016 ◽  
Vol 8 (10) ◽  
pp. E1260-E1267 ◽  
Author(s):  
Vaibhav R. Vaidya ◽  
Roshini Asirvatham ◽  
Jason Tri ◽  
Samuel J. Asirvatham

2012 ◽  
Vol 44 (3) ◽  
pp. 211-219 ◽  
Author(s):  
Nicola Cooley ◽  
Mark J. Cowley ◽  
Ruby C. Y. Lin ◽  
Silvana Marasco ◽  
Chiew Wong ◽  
...  

Chronic atrial fibrillation (AF) is a complication associated with the dilated atria of patients with valvular heart disease and contributes to worsened pathology. We examined microRNA (miRNA) expression profiles in right and left atrial appendage tissue from valvular heart disease (VHD) patients. Right atrial (RA) appendage from patients undergoing coronary artery bypass grafting and left atrial (LA) appendage from healthy hearts, not used for transplant, were used as controls. There was no detectable effect of chronic AF on miRNA expression in LA tissue, but miRNA expression in RA was strongly influenced by AF, with 47 miRNAs (15 higher, 32 lower) showing differential expression between the AF and control sinus rhythm groups. VHD induced different changes in miRNA expression in LA compared with RA. Fifty-three (12 higher, 41 lower) miRNAs were altered by VHD in LA, compared with 5 (4 higher, 1 lower) in RA tissue. miRNA profiles also differed between VHD-LA and VHD-RA (13 higher, 26 lower). We conclude that VHD and AF influence miRNA expression patterns in LA and RA, but these are affected differently by disease progression and by the development of AF. These findings provide new insights into the progression of VHD.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Katsuomi Iwakura ◽  
Hiroshi Ito ◽  
Atsunori Okamura ◽  
Yasushi Koyama ◽  
Motoo Date ◽  
...  

Patients with atrial fibrillation (AF) are frequently associated with reduced left ventricular (LV) diastolic dysfunction. It is still unclear whether reduced diastolic function is associated with the risk of left atrial (LA) thrombus in AF. The ratio of transmitral E velocity to mitral annular velocity (e′) is an echocardiographic estimate of diastolic LV filling pressure even under AF rhythm. We investigated whether reduced LV diastolic function is associated with the risk of LA thrombus in AF patients, using E/e′ ratio as an index. We enrolled consecutive 405 patients with non-valvular, paroxysmal or chronic AF, who underwent both transthoracic- (TTE) and transesophagial echocardiography (TEE) examination within a month. We measured LA and LV dimensions, LV ejection fraction (%EF), wall thickness, E and e′ velocities on TTE, and determined E/e′ ratio. LA appendage thrombus was found in 33 patients (8.1%). Patients with LA thrombus showed lower e′ velocity (5.3±1.8 vs. 7.0±2.2 cm/s, p<.0001) and higher E/e′ ratio (17.2±9.2 vs. 11.5±5.9, p<.0001) than those without it. Using 12.4 as an optimal cutoff point, E/e′ predicted LA thrombus with 70% sensitivity and 70% specificity (AUC=0.72). Odds ratio for LA thrombus in patients in the highest quartile of E/e′ was 6.38 (3.06–13.9). Multivariate logistic regression analysis indicated that the highest quartiles of E/e′ ratio was an independent predictor of LA thrombus among echocardiographic parameters, along with LA dimension and %EF, whereas e′ was not. LA appendage flow velocity was significantly correlated with E/e′ ratio (p<.0001), implying that increased diastolic filling pressure could be associated with impaired blood flow within LA. Increased LV filling pressure increased the risk of LA thrombus in patients with AF, partially through impaired LA hemodynamics. E/e′ ratio on TTE could be useful for detecting high-risk patients for LA thrombus.


2021 ◽  
Author(s):  
Takafumi Oka ◽  
Yasushi Koyama ◽  
Koji Tanaka ◽  
Yuko Hirao ◽  
Nobuaki Tanaka ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document