A New Reversed-Dispersive Micro-Solid-Phase Extraction of Organophosphorus Pesticides Based on Three-Dimensional Magnetic Nanoparticles Supported by Graphene-Carbon Nanotubes Nanocomposite

2019 ◽  
Vol 13 (2) ◽  
pp. 170-174
Author(s):  
Caixia Yuan ◽  
Yingwen Qian ◽  
Xia Hong ◽  
Huan Wang ◽  
Haining He ◽  
...  
RSC Advances ◽  
2016 ◽  
Vol 6 (30) ◽  
pp. 24853-24864 ◽  
Author(s):  
Hamid Rashidi Nodeh ◽  
Wan Aini Wan Ibrahim ◽  
Mohd Marsin Sanagi ◽  
Hassan Y. Aboul-Enein

A new adsorbent based on magnetic nanoparticles (Fe3O4), graphene and cyanopropyltriethoxysilane was fabricated and applied to the magnetic solid phase extraction of organophosphorus pesticides.


2015 ◽  
Vol 7 (14) ◽  
pp. 5862-5868 ◽  
Author(s):  
Ya-lei Dong ◽  
Dong-qiang Guo ◽  
Hong Cui ◽  
Xiang-jun Li ◽  
Yu-jian He

Magnetic nanoparticles immobilized with Ti4+ are employed to develop an mSPE-CE method for extracting organophosphorus pesticides based on affinity extraction.


2016 ◽  
Vol 6 (3) ◽  
pp. 74-77
Author(s):  
Maryam Hosseini ◽  
◽  
Hasan Abbasinia ◽  
Abdorrasoul Malekpour ◽  
Tahereh Tarian ◽  
...  

2020 ◽  
Vol 16 (4) ◽  
pp. 381-392
Author(s):  
Ayman A. Gouda ◽  
Ali H. Amin ◽  
Ibrahim S. Ali ◽  
Zakia Al Malah

Background: Cadmium (Cd2+) and lead (Pb2+) have acute and chronic effects on humans and other living organisms. In the present work, new, green and accurate dispersive micro solid-phase extraction (DμSPE) method for the separation and preconcentration of trace amounts of cadmium (Cd2+) and lead (Pb2+) ions in various food, water and tobacco samples collected from Saudi Arabia prior to its Flame Atomic Absorption Spectrometric (FAAS) determinations was developed. Methods: The proposed method was based on a combination of oxidized multiwalled carbon nanotubes (O-MWCNTs) with a new chelating agent 5-benzyl-4-[4-methoxybenzylideneamino)-4H- 1,2,4-triazole-3-thiol (BMBATT) to enrich and separate trace levels of Cd2+ and Pb2+. The effect of separation parameters was investigated. The validation of the proposed preconcentration procedure was performed using certified reference materials. Results: Analyte recovery values ranged from 95-102%, indicating that the method is highly accurate. Furthermore, precision was demonstrated by the relative standard deviation (RSD < 3.0%). The limits of detection were 0.08 and 0.1 μg L−1 for Cd2+ and Pb2+ ions, respectively. The preconcentration factor was 200. Conclusion: The proposed method was used for the estimation of Cd2+ and Pb2+ ion content in various real samples, and satisfactory results were obtained. The proposed method has high adsorption capacity, rapid adsorption equilibrium, extremely low LODs, high preconcentration factors and shortens the time of sample preparation in comparison to classical SPE.


Sign in / Sign up

Export Citation Format

Share Document