Improved Removal Rates for Retrievable Inferior Vena Cava Filters with the Use of a ‘Filter Registry’

2012 ◽  
Vol 78 (1) ◽  
pp. 94-97 ◽  
Author(s):  
Michael Kalina ◽  
Marilyn Bartley ◽  
Mark Cipolle ◽  
Glen Tinkoff ◽  
Scott Stevenson ◽  
...  

The American Association for the Surgery of Trauma challenged the trauma community to improve a 22 per cent average removal rate for retrievable inferior vena cava filters (r-IVCFs). Since 2006, we maintained a “filter registry” documenting all IVCFs placed in trauma patients. Our goal was to improve removal rates for r-IVCF. Patients receiving an IVCF before implementation of filter registry, 2003–2005, comprised the control group. Patients receiving an IVCF after implementation of filter registry, 2006–2009, comprised the study group. Data obtained included age, gender, Injury Severity Score (ISS), length of stay (LOS), mortality, filter inserted, placement indication, removal rates, and reasons why removal did not occur. Fisher exact test and chi square were used for nominal variables. Stepwise logistic regression analysis was used to define predictors of removing and not removing an IVCF. Three hundred seven patients received an IVCF, 142 preregistry and 165 post-registry. No significant difference existed between groups in age, gender, ISS, placement indication, or mortality. A significant difference existed between groups in LOS and presence of deep vein thrombosis (DVT) and pulmonary embolism. A total of 98.2 per cent of postregistry patients received a Günther Tulip filter and all retrievals were performed by Interventional Radiology. Retrieval rates improved, 15.5 to 31.5 per cent post registry ( P < 0.001). No differences existed in lost to follow-up (LTF) between groups. Univariate analysis identified age, IVC clot, DVT, and LTF as predictors for not removing a filter. Stepwise logistic regression revealed the filter registry independently predicts the removal of an r-IVCF. A filter registry is effective in improving rates of removal for r-IVCFs.

2019 ◽  
Vol 213 (4) ◽  
pp. 768-777 ◽  
Author(s):  
Ronald S. Winokur ◽  
Noy Bassik ◽  
David C. Madoff ◽  
David Trost

TH Open ◽  
2021 ◽  
Vol 05 (01) ◽  
pp. e73-e80
Author(s):  
Filip Ionescu ◽  
Nwabundo Anusim ◽  
Eva Ma ◽  
Lihua Qu ◽  
LeAnn M. Blankenship ◽  
...  

AbstractRecognition of the adverse events of inferior vena cava filters (VCFs) has prompted the Food and Drug Administration (FDA) to issue safety warnings (2010 and 2014), advocating for removal, once the risk of pulmonary embolism has abated. Despite an initial increase in retrieval rates, these remain low (25–30% at 1 year in 2014). We retrospectively investigated retrieval trends in adults with VCFs placed between 2015 and 2018 at a single institution. The rate of retrievable VCF removal accounting for the competing risk of death was the main outcome. There were 494 VCFs placed (305 retrievable). The cumulative incidence of retrieval remained low (21% at 1 year), even after the second FDA warning (2014). Patients who resumed anticoagulation (AC) at any time were more likely to have retrieval (hazard ratio [HR] = 3.6, p < 0.01) and had higher retrieval rates at every time point (31.4 vs. 7.6% at 1 year). Advanced age (HR = 0.98 per year, p = 0.004), stroke (HR = 0.28, p = 0.028), and active malignancy (HR = 0.42, p = 0.006) predicted nonretrieval. Device-related complications were infrequent (<1%) but thrombotic complications occurred early and were more common for nonretrieved VCFs (17 vs. 12%, p = 0.29). Revision of guidelines to recommend active surveillance for the ability to tolerate AC in the immediate postimplantation period may improve retrieval rates.


Author(s):  
Anil Pillai ◽  
Manoj Kathuria ◽  
Maria del Pilar Bayona Molano ◽  
Patrick Sutphin ◽  
Sanjeeva P Kalva

2021 ◽  
pp. 026835552092598
Author(s):  
Jacob J Bundy ◽  
Jeffrey Forris Beecham Chick ◽  
Ravi N Srinivasa ◽  
Kyle J Cooper ◽  
Joseph J Gemmete ◽  
...  

Objective The Simon Nitinol filter is a bi-level filtration device designed for permanent implantation that is no longer commercially available, but may result in similar complications to current commercially available long term indwelling temporary or permanent filters. Complications related to indwelling inferior vena cava filters include inferior vena cava thrombosis, inferior vena cava penetration, filter migration, and filter fracture. There is a paucity of reports describing the technical aspects related to retrieval of Simon Nitinol filters. Materials and methods This study consisted of five patients with Simon Nitinol filters and describes the indication for retrieval, the retrieval techniques used to remove the filters, technical success, complications, and clinical course. Results The indications for retrieval included: abdominal pain ( n = 2; 40%), iliocaval thrombosis ( n = 1; 20%), identification of an intracardiac filter fragment ( n = 1; 20%), and recurrent venous thromboembolic events ( n = 1; 20%). Retrieval techniques included: biopsy forceps ( n = 3; 60%), excimer laser extraction sheaths ( n = 3; 60%), hangman modified loop snares ( n = 3; 60%), rigid endobronchial forceps ( n = 2; 40%), and balloon deflection ( n = 2; 40%). All filters were successfully retrieved. One patient developed a post-procedural intramuscular hematoma near the site of right internal jugular sheath placement. Conclusions Simon Nitinol filters may be retrieved safely and effectively using advanced inferior vena cava filter retrieval techniques.


2017 ◽  
Vol 38 (01) ◽  
pp. 084-093 ◽  
Author(s):  
Jonathan Steinberger ◽  
Anshuman Bansal ◽  
John Moriarty

2012 ◽  
Vol 55 (6) ◽  
pp. 60S
Author(s):  
Elsie Gyang ◽  
Mohamed Zayed ◽  
E. John Harris ◽  
Jason T. Lee ◽  
Ronald L. Dalman ◽  
...  

Sign in / Sign up