Contrast-enhanced ultrasound (CEUS) reliably rules out neoplasm in developmental renal pseudotumor

2020 ◽  
pp. 028418512093929
Author(s):  
Paul Spiesecke ◽  
Thomas Fischer ◽  
Andreas Maxeiner ◽  
Bernd Hamm ◽  
Markus H Lerchbaumer

Background Renal pseudotumors appear as benign cortical hypertrophies and are typically assessed by contrast-enhanced computed tomography or magnetic resonance imaging to rule out malignancy. Purpose To investigate whether contrast-enhanced ultrasound (CEUS) can rule out renal neoplasm and thus potentially reduce cross-sectional imaging and further follow-up in these patients. Material and Methods Thirty-two patients with presumption of developmental renal pseudotumor on CEUS between June 2011 and July 2019 were retrospectively analyzed. All patients were examined with a standardized renal US protocol including B-mode, color-coded duplex sonography (CCDS), and CEUS by an experienced radiologist (EFSUMB level 3). Images were retrospectively interpreted in consensus by two highly experienced radiologists. Histopathological reports, cross-sectional imaging findings, and clinical course (treatment response, long-term imaging follow-up) were defined as standard of reference. Results CEUS correctly identified 8/9 neoplastic lesions and missed one oncocytoma within the 32 included patients. Irregular vessel structure (88.9% vs. 13.0%, P = 0.007) and hyperenhancement (66.6% vs. 17.4%, P = 0.031) on CEUS were more common in neoplasm compared to developmental pseudotumors reaching statistical significance. Compared with the standard of reference, CEUS had 89% sensitivity (95% confidence interval [CI] 57–98), 96% specificity (95% CI 80–99), a positive predictive value of 89% (95% CI 57–98), and a negative predictive value of 96% (95% CI 79–99) for ruling out renal malignancy in developmental pseudotumors. Conclusion CEUS is a safe and fast method to rule out neoplasm in the diagnostic work-up of renal pseudotumors. In conjunction with B-mode and CCDS, CEUS has the potential to reduce further (invasive) diagnostic procedures.

2021 ◽  
pp. 1-6
Author(s):  
François Audenet ◽  
Jordan Sapetti ◽  
Christophe Delavaud ◽  
Virginie Verkarre ◽  
Jean-Michel Correas ◽  
...  

<b><i>Introduction:</i></b> Indeterminate renal cysts may require several imaging modalities before clinical decision. The aim of this study was to investigate the effect of the imaging modality used to characterize indeterminate renal cysts on the pathological findings after surgical resection. <b><i>Methods:</i></b> From our institutional database, we identified all patients surgically treated for Bosniak III renal masses between January 2008 and January 2018. All complex renal cysts were characterized with a combination of computed tomography (CT) and/or magnetic resonance imaging (MRI), and/or contrast-enhanced ultrasound (CEUS) and discussed during a multidisciplinary tumor board. Potential association between clinical/radiological characteristics and the pathological findings were investigated, using univariate and multivariate analyses. <b><i>Results:</i></b> Of the 52 renal cystic lesions surgically removed, with a preoperative diagnosis of Bosniak III renal cyst, 19 (37%) were malignant and 33 (63%) were benign. The proportion of malignant lesions decreased from 47% when the renal cyst was characterized with cross-sectional imaging (CT and/or MRI) to 17% when the diagnosis required CEUS in addition to cross-sectional imaging. In multivariate analysis, prior history of renal cell carcinoma was associated with a higher risk of malignancy (<i>p</i> = 0.016) and diagnosis made with CEUS was associated with a lower risk of malignancy (<i>p</i> = 0.040). <b><i>Conclusion:</i></b> We found that using CEUS in addition to cross-sectional imaging to characterize indeterminate renal cysts tends to redefine Bosniak III as lesions with a lower risk of malignancy and can lead to overclassification.


2020 ◽  
Vol 74 (3) ◽  
pp. 327-339 ◽  
Author(s):  
Timo Alexander Auer ◽  
Thomas Fischer ◽  
Stephan Rodrigo Marticorena Garcia ◽  
Tobias Penzkofer ◽  
Ernst-Michael Jung ◽  
...  

VASA ◽  
2014 ◽  
Vol 43 (1) ◽  
pp. 6-26 ◽  
Author(s):  
Fabian Rengier ◽  
Philipp Geisbüsch ◽  
Paul Schoenhagen ◽  
Matthias Müller-Eschner ◽  
Rolf Vosshenrich ◽  
...  

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.


2012 ◽  
Vol 63 (3) ◽  
pp. 215-221 ◽  
Author(s):  
Dellano D. Fernandes ◽  
Ram Prakash Galwa ◽  
Najla Fasih ◽  
Margaret Fraser-Hill

Small bowel malignancies are rare neoplasms, usually inaccessible to conventional endoscopy but detectable in many cases by cross-sectional imaging. Modern multidetector computed tomographies permit accurate diagnosis, complete pretreatment staging, and follow-up of these lesions. In this review, we describe the cross-sectional imaging features of the most frequent histologic subtypes of the small bowel malignancies.


2019 ◽  
Vol 70 (4) ◽  
pp. 434-440
Author(s):  
Mostafa Atri ◽  
Abdulmohsen Alrashed ◽  
Ahmad Hassan ◽  
Korosh Khalili ◽  
Tae Kyoung Kim ◽  
...  

Purpose To determine negative predictive value (NPV) of contrast-enhanced ultrasound (CEUS) to demonstrate local tumour progression (LTP) at thermal ablation (TA) sites. Methods Our institutional review board approved this retrospective study; acquisition of consent was waived. Consecutive CEUS examinations performed between 2004-2014 for TA site evaluation on patients who could not undergo enhanced computed tomography (CT) or magnetic resonance imaging (MRI), or had inconclusive CT or MRI, were retrospectively reviewed. Those reported as no abnormal enhancement in or surrounding TA site were included. CEUS examination was considered true-negative based on stability or lack of enhancement/washout on follow-up imaging for at least 1 year, and false-negative (FN), if there was an arterially enhancing focus with wash-out at or surrounding TA site on subsequent follow-up imaging. Results Study population included 56 tumours in 54 patients, 11 women, 43 men; mean age 71 years. Two patients had TA of two different hepatocellular carcinomas. Thirty-six examinations were for hepatic TA and twenty for renal TA. Lesion sizes ranged from 1 cm to 7 cm (mean 3.1 ± 1.2). Mean diameter of 7 recurrences was 13.8 mm. Overall FN rate was 12.5% (7/56). Corresponding numbers were 0% (0/20) for renal TA and 19.4% (7/36) for hepatic TA. Overall NPV of CEUS was 87.5% (49/56) (confidence interval [CI]: 78.8%–96.2%). NPV for renal TA was 100% (20/20) (CI: 100%–100%) and for hepatic TA 81.5% (29/36) (CI: 67.6 %–93.5%). Conclusion In this cohort, CEUS showed high NPV for exclusion of LTP at renal TA sites. NPV for hepatic TA sites was high but lower than renal TA.


2019 ◽  
Vol 21 (1) ◽  
pp. 16 ◽  
Author(s):  
Corrado Tagliati ◽  
Giulio Argalia ◽  
Gian Marco Giuseppetti

Aims: To assess contrast enhanced ultrasound (CEUS) performance in the prediction of non-operatively managed blunt spleen injuries requiring only observation and monitoring during follow-up and to evaluate if CEUS accuracy was higher than conventional ultrasound (US) in this field.Material and methods: In 112 hemodynamic stable blunt spleen trauma patients, CEUS was performed for follow-up after computed tomography evaluation in the emergency department. CEUS and US performance were assessed considering as true negative cases patients that had not underwent interventional or surgical treatment during follow-up and were assessed as negative for splenic complications respectively by CEUS or US examinations.Results: CEUS showed sensitivity of 100%, specificity of 96.1%, positive predictive value of 69.2%, negative predictive value of 100.0% and accuracy of 96.4%. CEUS showed a significantly higher accuracy than conventional US (p=0.013).Conclusions: CEUS is a very useful imaging modality during follow-up of blunt splenic trauma non-operatively managed, allowing an efficientprediction of splenic injuries requiring only observation and monitoring during follow-up.


2014 ◽  
Vol 28 (7) ◽  
pp. 385-390
Author(s):  
Brian A Brunson ◽  
Robert Hawes ◽  
Brenda Hoffman ◽  
Stacie Vela ◽  
Joseph Romagnuolo

BACKGROUND: Cross-sectional imaging remains the first-line test for obstructive jaundice despite high miss rates for pancreatobiliary tumours. Improvements in resolution and slice thickness of spiral computed tomography/magnetic resonance imaging/magnetic resonance cholangiopancreatography promised to increase accuracy.OBJECTIVE: To assess whether the post-test probability of neoplasm is truly altered by the presence or absence of a mass on computed tomography/magnetic resonance imaging in obstructive jaundice.METHODS: The institutional endoscopic ultrasound (EUS) database was retrospectively reviewed to stratify patients presenting to EUS over a two-year period for obstructive jaundice (suspicious for malignancy) according to their pre-EUS imaging results. The primary analysis involved the calculation of the positive predictive value and negative predictive value (NPV) of imaging with 95% binomial CIs. Test performance of EUS/fine-needle aspiration (FNA) was also calculated. Final diagnosis was determined by positive cytology/histology; negative EUS was supplemented by clinical follow-up.RESULTS: The positive predictive value (n=51) and NPV (n=53) of pre-EUS imaging was 98% (95% CI 90% to 100%) and 9% (95% CI 3% to 21%), respectively (accuracy 53%), with post-test suspicion of malignancy similar between imaging-positive and -negative groups. EUS demonstrated a mass in 96% of imaging-positive cases versus 85% in imaging-negative cases (exact P=0.09). Malignant or suspicious FNA cytology was obtained with EUS in 92% of the imaging-positive group, and 62% of the imaging-negative group (75% of subgroup with FNA) (P<0.001).CONCLUSION: Lack of a definite mass on pre-EUS imaging had low NPV, and was clearly not sufficiently accurate or reassuring in this clinical setting. In suspicious obstructive jaundice, EUS with FNA has a high diagnostic yield regardless of the findings of pre-EUS cross-sectional imaging and, as such, EUS may be a more reasonable first-line test in this high-suspicion setting.


Ultrasound ◽  
2021 ◽  
pp. 1742271X2110479
Author(s):  
Alice Tee ◽  
Gibran Timothy Yusuf ◽  
Adrian Wong ◽  
Deepak Rao ◽  
Sa Tran ◽  
...  

Objectives Bedside lung ultrasound has been indispensable during the coronavirus disease 2019 (COVID-19) pandemic, allowing us to rapidly assess critically unwell patients. We demonstrate the unique application of contrast-enhanced ultrasound with the aim of further understanding this disease. Methods Patient demographics were recorded alongside recent cross-sectional imaging and inflammatory markers. Ultrasound was conducted by experienced operators in a portable setting. Conventional six-point lung ultrasound method was used to evaluate B-lines, small (subpleural) consolidation and the pleura. Areas of small consolidation were targeted after intravenous administration of ultrasound contrast. Results The areas of small consolidations, a potential sign of pneumonia on B-mode lung ultrasound, usually enhance on contrast-enhanced ultrasound. Our study revealed these areas to be avascular, indicating an underlying thrombotic/infarction process. Findings were present in 100% of the patients we examined. We have also shown that the degree of infarction correlates with CT severity (r = 0.4) and inflammatory markers, and that these areas improve as patients recover. Conclusions We confirmed the theory of immune thrombus by identifying the presence of microthrombi in the lungs of 100% of our patients, despite 79% having had a recent negative CT pulmonary angiogram study. contrast-enhanced ultrasound can be utilised to add confidence to an uncertain COVID-19 diagnosis and for prognosticating and monitoring progress in confirmed COVID-19 patients. Contrast-enhanced ultrasound is clearly very different to CT, the gold standard, and while there are specific pathologies that can only be detected on CT, contrast-enhanced ultrasound has many advantages, most notability the ability to pick up microthrombi at the periphery of the lungs.


Sign in / Sign up

Export Citation Format

Share Document