Effect of minimonovision in bilateral implantation of a novel non-diffractive extended depth-of-focus intraocular lens: Defocus curves, visual outcomes, and quality of life

2021 ◽  
pp. 112067212110640
Author(s):  
Marco Coassin ◽  
Tommaso Mori ◽  
Antonio Di Zazzo ◽  
Maria Poddi ◽  
Roberto Sgrulletta ◽  
...  

Purpose To evaluate overall patient satisfaction, spectacle independence, visual acuity, and prevalence of optical phenomena following bilateral implantation of a new non-diffractive extended depth-of-focus intraocular lens targeted for minimonovision. Methods Multicenter prospective case series. Postoperative far and near visual acuity at 3 months and patient quality of life by NEI-VFQ-25 questionnaire were assessed. Postoperative evaluation included defocus curves analysis, spectacle independence assessment, and recording of photic phenomena. Results The study enrolled 97 eyes of 59 patients that underwent femtosecond-assisted cataract surgery with AcrySof IQ Vivity intraocular lens implantation. Thirty subjects (60 eyes) were eligible for analysis. After 3 months, postoperative achieved binocular uncorrected visual acuity was −0.03  ±  0.06 logarithm of the minimum angle of resolution for distance, 0.06  ±  0.06 logarithm of the minimum angle of resolution for intermediate, and 0.19  ±  0.03 logarithm of the minimum angle of resolution for near. Defocus curve showed a smooth profile with no abrupt decrease of visual acuity. Minimonovision significantly improved visual acuity compared to when minimonovision was neutralized, for values of defocus curves from −1 to −3 D ( p < 0.05). Twenty-six (87%) patients reported complete spectacle independence. High levels of satisfaction for distance and near vision resulted at VFQ-25 questionnaire. Only two patients complained of halos (6.7%) and one of them also of glare (3.3%). Conclusions Implantation of this new non-diffractive extended depth-of-focus intraocular lens with minimonovision resulted in satisfying far, intermediate, and near visual acuity with a consistent reduction of spectacle dependence and improvement in patient's quality of life.

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Rahul T. Pandit

Importance. A full range of near and intermediate vision has not been clinically evaluated for the Symfony extended depth of focus intraocular lens (EDOF IOL). Background. To evaluate the monocular range of near visual acuity with an EDOF IOL. Design. Retrospective case series. Participants. Consecutive patients of a single surgeon from January 2017 through March 2018. Methods. Phacoemulsification with implantation of an EDOF IOL. Main Outcome Measures. Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), range of DCNVA, and optimal near focal length. Results. Seventy-six eyes of 48 patients (34 or 71% female, mean age: 68 years) were included with a mean follow-up of 68 days. Mean values were as follows: logarithm of the minimum angle of resolution (logMAR) UDVA 0.02 ± 0.09, logMAR UNVA 0.12 ± 0.09 at a mean distance of 51 cm, logMAR CDVA −0.05 ± 0.07, logMAR DCNVA 0.08 ± 0.07 at a mean distance of 51 cm, and a spherical equivalent of −0.16 diopters ±0.35. Percentage of eyes achieving DCNVA of 20/30 were 84% at 36 cm, 92% at 41 cm, 99% at 51 cm, 93% at 61 cm, and 74% at 71 cm. DCNVA of 20/40 or better was achieved in nearly 100% of eyes over a range of 35 cm. Conclusions and Relevance. The Symfony EDOF IOL achieved excellent distance visual acuity while providing a 35 cm range of near visual acuity at levels useful for many tasks in nearly all patients.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yueyang Zhong ◽  
Kai Wang ◽  
Xiaoning Yu ◽  
Xin Liu ◽  
Ke Yao

AbstractThis meta-analysis aimed to evaluate the clinical outcomes following implantation of trifocal intraocular lenses (IOLs) or a hybrid multifocal-extended depth of focus (EDOF) IOL in cataract or refractive lens exchange surgeries. We examined 13 comparative studies with bilateral implantation of trifocal (898 eyes) or hybrid multifocal-EDOF (624 eyes) IOLs published through 1 March 2020. Better uncorrected and corrected near visual acuity (VA) were observed in the trifocal group (MD: − 0.143, 95% CI: − 0.192 to − 0.010, P < 0.001 and MD: − 0.149, 95% CI: − 0.217 to − 0.082, P < 0.001, respectively), while the hybrid multifocal-EDOF group presented better uncorrected intermediate VA (MD: 0.055, 95% CI: 0.016 to 0.093, P = 0.005). Trifocal IOLs were more likely to achieve spectacle independence at near distance (RR: 1.103, 95% CI: 1.036 to 1.152, P = 0.002). The halo photic effect was generated more frequently by the trifocal IOLs (RR: 1.318, 95% CI: 1.025 to 1.696, P = 0.031). Contrast sensitivity and subjective visual quality yielded comparable results between groups. Trifocal IOLs demonstrated better performance at near distance but apparently led to more photic disturbances. Our findings provided the most up-to-date and comprehensive evidence by comparing the benefits of advanced IOLs in clinical practice.


Author(s):  
Makoto Inoue ◽  
Nina Teresa Aicher ◽  
Yuji Itoh ◽  
Hiroko Bissen-Miyajima ◽  
Akito Hirakata

2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
John S. M. Chang ◽  
Jack C. M. Ng ◽  
Vincent K. C. Chan ◽  
Antony K. P. Law

Purpose. To report visual performance and quality of life after implantation of a bifocal diffractive multifocal intraocular lens (MIOL) in postmyopic laser in situ keratomileusis (LASIK) patients.Methods. Prospective, observational case series. Patients with prior myopic LASIK who had implantation of Tecnis ZMA00/ZMB00 MIOL (Abbott Medical Optics) at Hong Kong Sanatorium and Hospital were included. Postoperative examinations included monocular and binocular distance, intermediate and near visual acuity (VA), and contrast sensitivity; visual symptoms (0–5); satisfaction (1–5); spectacle independence rate; and quality of life.Results. Twenty-three patients (27 eyes) were included. No intraoperative complications developed. Mean monocular uncorrected VA at distance, intermediate, and near were0.13±0.15(standard deviation),0.22±0.15, and0.16±0.15, respectively. Corresponding mean values for binocular uncorrected VA were0.00±0.10,0.08±0.13, and0.13±0.10, respectively. No eyes lost >1 line of corrected distance VA. Contrast sensitivity at different spatial frequencies between operated and unoperated eyes did not differ significantly (allP>0.05). Mean score for halos, night glare, starbursts, and satisfaction were1.46±1.62,1.85±1.69,0.78±1.31, and3.50±1.02, respectively. Eighteen patients (78%) reported complete spectacle independence. Mean composite score of the quality-of-life questionnaire was90.31±8.50out of 100.Conclusions. Implantation of the MIOL after myopic LASIK was safe and achieved good visual performance.


2020 ◽  
Vol 46 (1) ◽  
pp. 108-115 ◽  
Author(s):  
Yumi Lee ◽  
Grzegorz Łabuz ◽  
Hyeck-Soo Son ◽  
Timur M. Yildirim ◽  
Ramin Khoramnia ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Toshihiro Sakisaka ◽  
Keiichiro Minami ◽  
Keita Takada ◽  
Yosai Mori ◽  
Kazunori Miyata

Abstract Background The prospective comparative case series aimed to evaluate all-distance visual acuity, contrast sensitivity, and functional visual acuity (FVA) of eyes with diffractive extended depth-of-focus (EDOF) intraocular lenses (IOLs) using an echelett optics and monofocal IOLs with the same platform. Methods Diffractive EDOF and monofocal IOLs were implanted in 27 eyes of 27 patients each. At 3 months after implantation, all-distance visual acuities at distances of 0.3, 0.5, 0.7, 1, 2, 3, and 5 m were measured under distance-corrected. Static visual function was also examined using photopic contrast sensitivity and area under the logarithmic contrast sensitivity function (AULCSF). Dynamic visual function was examined with FVA, and mean FVA value, visual maintenance ratio (VMR), mean response time, and number of blinks were evaluated. These outcomes were compared between the two IOLs. Results The mean distance-corrected visual acuities were better at distances of 0.7 m or nearer in eyes with EDOF IOLs. There was no difference in the contrast sensitivities (P > 0.22). In the FVA results, no difference was found in mean FVA and VMR (P > 0.68). Conclusion The static and dynamic evaluations of postoperative visual functions demonstrated that the visual function of eyes with EDOF IOLs under photopic and distance-corrected conditions was comparable to eyes with monofocal IOLs.


2019 ◽  
Author(s):  
Jing Liu ◽  
Yi Dong ◽  
Yan Wang

Abstract Background : This study aims to evaluate the efficacy and safety of extended depth of focus (EDOF) intraocular lenes (IOLs) in cataract surgery. Methods: All comparative clinical trials that involved bilaterally implanting EDOF IOLs in patients with cataract were retrieved from the literature database. We used random effects models to pool weighted mean differences (WMD) and risk ratio (RR) for continuous and dichotomous variables, respectively. Results: Nine studies with a total of 1336 eyes were identified. The subgroup analysis was conducted according to the type of IOLs used in the control group. Compared with monofocal IOLs, EDOF IOLs produced better uncorrected intermediate visual acuity (WMD: -0.17, 95% CI: -0.26 to -0.08, P = 0.0001) and uncorrected near visual acuity (WMD: -0.17, 95% CI: -0.21 to -0.12, P < 0.00001). EDOF IOLs resulted in reduced contrast sensitivity, more frequent halos, however, higher spectacle independence (RR: 2.81, 95% CI: 1.06 to 7.46, P = 0.04) than monofocal IOLs. Compared with trifocal IOLs, EDOF IOLs produced worse near visual acuity (MD: 0.10, 95% CI: 0.07 to 0.13, P<0.0001). EDOF IOLs performed better than trifocal IOls in contrast sensitivity, and there were no significant difference in halos and spectacle independence. Serious postoperative complications were rare, with no adverse events were reported in most studies. Conclusions: Increasing the risk of contrast reduction and more frequent halos, EDOF IOLs provided better intermediate and near VAs than monofocal IOLs. At the expense of near vision, patients receiving EDOF IOLs have better contrast sensitivity than those receiving trifocal IOLs. Halo incidence and spectacle independence of EDOF IOLs were similar to those of trifocal IOLs.


Sign in / Sign up

Export Citation Format

Share Document