Contact Dermatitis to Personal Sporting Equipment in Youth

2015 ◽  
Vol 20 (4) ◽  
pp. 323-326 ◽  
Author(s):  
Barbara Marzario ◽  
Dianne Burrows ◽  
Sandy Skotnicki

Background: Contact dermatitis to personal sporting equipment in youth is poorly studied. Objective: To review the results of patch testing 6 youth to their sporting equipment in a dermatology general private practice from 2006 to 2011. Methods: A retrospective analysis of 6 youth aged 11 to 14 who were evaluated for chronic and persistent dermatitis occurring in relation to sports equipment was conducted. All patients were subjected to epicutaneous (patch) testing, which included some or all of the following: North American Contact Dermatitis Group (NACGD) series, textile series, rubber series, corticosteroid series, and raw material from the patients’ own personal equipment. Results: All cases had 1 or more positive patch test reactions to an allergen within the aforementioned series, and 3 subjects tested positive to their personal equipment in raw form. Conclusions: Allergic contact dermatitis, not irritant, was deemed the relevant cause of chronic dermatitis in 4 of the 6 patients due to positive reactions to epicutaneous tests and/or personal equipment. The utility of testing to patients’ own sporting equipment was shown to be of additional value and should be considered when patch testing for contact allergy to sporting equipment.

2015 ◽  
Vol 19 (1) ◽  
pp. 77-80 ◽  
Author(s):  
Kathleen Fraser ◽  
Melanie Pratt

Background: In allergic contact dermatitis (ACD), polysensitization consists of positive patch test reactions to three or more unrelated allergens. Objective: The purpose of this case report is to document a 27-year-old female with recurrent lip dermatitis, polysensitization, and reactions to a number of clinically relevant exposures. Methods: Patch testing results revealed positive reactions to tixocortol-21-pivalate (3+), lanolin (3+), neomycin (3+), nickel (1+), hydroxyethyl methylacrylate (3+), bacitracin (3+), and abitol (3+). Results: The patient had seven positive reactions, meeting the criteria for polysensitization. Of known clinical relevance, the patient had applied lanolin-containing lip balms and hydrocortisone- and bacitracin-containing products to the lips, all of which she was strongly reactive to on patch testing. Conclusion: Polysensitization occurs when three or more unrelated allergens are positive on patch testing. This case highlights the importance of considering polysensitization in ACD as numerous allergens that were positive on patch testing were clinically relevant.


2019 ◽  
Vol 70 (4) ◽  
pp. 1337-2341 ◽  
Author(s):  
Maria-Magdalena Constantin ◽  
Stefana Bucur ◽  
Clara Matei ◽  
Iuliana Elena Nita ◽  
Traian Constantin

In Romania, data on patch testing are lacking and the significance and applicability of the European baseline series (EBS) needs to be evaluated. The aim of the study was to examine the prevalence of contact allergy to the EBS and to determine the most common post-test sensitization occurred in the population of patients with suspected allergic contact dermatitis in Romania. Demographic data were collected from 252 patients with suspected allergic contact dermatitis. Pacients were patch tested with 28-allergen EBS.The positive patch test was observed in 80.16% patients. The most prevalent contact allergens were nickel sulphate (15.08%), fragrance mix I & II (13.10%) and potassium dichromate (9.52%). Differences in sensitization prevalences to some allergens of the EBS compared with other European countries were recognized. The current EBS is a suitable diagnostic tool for contact allergy in Romania.


2021 ◽  
Vol 0 ◽  
pp. 1-5
Author(s):  
Thacharamban Mansoorali ◽  
Abdulsalam Sarin

Objectives: The objective of the study was to identify the allergens showing positive patch test reaction (using Indian standard battery of allergens) in cement workers with clinically diagnosed allergic contact dermatitis (CD) to cement attending a tertiary referral center. Materials and Methods: We included cement workers with clinically diagnosed allergic CD to cement who attended the dermatology outpatient clinic of our tertiary referral center from January 2013 to December 2013. We did patch testing in all the cases ( after subsidence of active dermatitis) with Indian standard battery of patch test allergens and documented the allergens that showed a positive reaction. Results: Forty-seven (94%) of the 50 study participants showed a positive reaction to one or more of the allergens. The most common allergen that showed a positive reaction was potassium dichromate (43/50, 86%). Twenty-five patients (50%) showed positive reactions to more than 1 allergen. Four patients (8%) showed positive reactions only to allergens that were not seen in cement. Limitations: Small sample size and lack of information on clinical response of dermatitis to avoidance of identified allergen were the major limitations. Conclusion: Twenty-five (50%) patients showing positive reactions to more than 1 allergen tested and 4 (8%) showing positive patch test reaction to none of the allergens in cement (but to other allergens) highlight the role of patch testing in identifying the probable allergens in patients with clinically diagnosed allergic CD to cement.


2019 ◽  
Vol 19 (7) ◽  
pp. 1083-1087 ◽  
Author(s):  
Paolo Romita ◽  
Caterina Foti ◽  
Luca Stingeni ◽  
Katharina Hansel ◽  
Thea Magrone ◽  
...  

Background: The relationship between atopic dermatitis and allergic contact dermatitis is frequently debated, particularly in children. The impaired skin barrier of atopic subjects can facilitate the penetration of exogenous agents and its mutations in the filaggrin gene might be implicated in an increased risk to develop contact dermatitis. Moreover, atopic children are protractedly exposed to chemical substances contained in skin care products from an early age. Patients And Methods: The aim of this retrospective study is to determine if atopic children are more prone to allergic contact dermatitis and which substances are more frequently related to this disease. From 2014 to 2016, a total of 268 children under 14 years with a history of eczematous dermatitis, of whom 141 (52.6%) were affected, and 127 (47.4%) were not affected by AD, underwent patch testing with the baseline S.I.D.A.P.A standard series. Results: Based on the results of our study, the prevalence of contact allergy in atopic children is comparable to that noted in non-atopic children. The most frequent causes of contact allergy in children are fragrances, and their prevalence is significantly higher in atopic children (19.9%) than in non-atopic ones, (11.8%; p < .05). Conclusion: Our study highlights the importance of patch testing in atopic children for continuously monitoring the trends and changes of contact allergies that are a common disease and is even significantly increasing for some allergens, as fragrances. We may speculate that the protracted use of skincare products, associated with the impaired skin barrier of atopic children, enhances the risk of sensitization to the ingredients of these products.


2014 ◽  
Vol 18 (1) ◽  
pp. 15-19 ◽  
Author(s):  
Katie Beleznay ◽  
Gillian de Gannes ◽  
Sunil Kalia

Background: As the use of sunscreens becomes more prevalent, reports of adverse effects to sunscreens have increased. Objective: To analyze a patch test database for the prevalence of allergic contact dermatitis (ACD) to sunscreen. Methods: The database was searched for positive patch test reactions to benzophenone-3. Charts were also reviewed for those who were further tested to the sunscreen series. Results: Twenty-three of the 1,527 patients seen were tested to the sunscreen series. Of these, only 4 patients had a positive reaction to a sunscreen chemical or to the product they were using. In addition, 8 of the 1,527 patients who had no specific history of sunscreen allergy reacted to benzophenone-3. Conclusion: ACD to sunscreen was found to be very uncommon (0.8%). Other final diagnoses included ACD to excipients such as fragrances or preservatives and suspected photosensitive disorders.


2019 ◽  
Vol 77 (3) ◽  
pp. 221-225
Author(s):  
Mariana Ferreira Bastos ◽  
Ricardo Batista ◽  
Diogo Laertes ◽  
Joana Calvão ◽  
Margarida Gonçalo

Introduction. Occupational Allergic Contact Dermatitis is a very common occupational disease and epoxy resins are among its main causes. The aim of this study was to characterize patients with positive patch test reactions to epoxy resin detected in the Coimbra Hospital and University Center between 2012 and 2018 and compare with the results of patients patch tested between 1999 and 2008 at the same Institution. Method and Materials.  Within aretrospective analysis of the files of patients with positive patch test reactions (1+ or more intense) to epoxy resin of bisfenol A tested at 1% pet. within the Baseline Series between 2012 and 2018, we characterized demographic and clinical data of reactive patients, evaluated the relevance of the reaction, sources of exposure to epoxy resin with particular attention to occupational exposures, other positive reactions and the impact of the results of the tests in the work conditions of these patients. Lastly, we compared these results with a previous study performed in the same Hospital between 1999 and 2008. Results. Among 2363 patch tested patients during the study period we found 23 patients (0.97%), 17 males and 6 females, who developed contact allergy to epoxy resins. In 22 cases we identified a relevant occupational exposure: 9 from construction industry; 9 workers from wind-mill turbines factory for Eolic energy; 2 from fiberglass factories; 1 from a chemical factory and 1 from a Wastewater Treatment Plant. In 1 patient (a teacher) no relevance was found. Of these 22 workers, 9 (39.1%) had both hand and airborne lesions, while 8 (34.8%) had lesions exclusively on the hands and 5 (21.7%) had predominately airborne dermatitis. Four of the 23 (17.4%) reacted exclusively to the epoxy resin, and 11 of 18 (61.1%) also reacted to 0.25% hexanediol diglycidyl ether. Avoidance resulted in a significant improvement of symptoms. Compared to the previous period (1999-2008), there are no significative changes apart from a slight increase in the frequency of the allergic reactions to epoxy resins and its main source of exposure. Conclusions. The prevalence of allergic contact dermatitis to epoxy resin has slightly increased in this Portuguese Center mostly due to workers from wind-mill turbines factory for Eolic energy, a recent industry implanted in this region. This allergen still causes almost exclusively occupational dermatitis, either hand, airborne, or both.


2021 ◽  
Vol 23 (1) ◽  
pp. 16-22
Author(s):  
Arnija Rana ◽  
S Shrestha ◽  
AK Jha ◽  
DP Thapa ◽  
S Joshi ◽  
...  

Allergic contact dermatitis (ACD) is one of the most common diseases presenting to the Dermatology department. The one and only method of preventing as well as treating this disease is avoidance of the allergen causing it. The identification of the allergen causing the ACD is possible by performing patch testing. The purpose of this study was to identify common allergens among patients with ACD using Indian standard series (ISS) of patch test. Clinically suspected cases of ACD were included in the hospital based cross-sectional study from January to December 2017. These cases underwent patch testing with the ISS. The study assessed the following variables: sex, age, occupation, site and positive patch test results. There were a total of 58 patients among which, 36.2% were males and 63.8% were females with a mean age of 32.36±12.51 years. Positive patch test reactions were seen in 63.0% of patients. The most common allergens were nickel sulphate (51.4%), fragrance mix (37.8%), potassium dichromate (8.1%), colophony (8.1%) and black rubber mix (8.1%). Among male, most common allergens were fragrance mix (57.1%), nickel sulphate (28.6%) and potassium dichromate (21.4%) while in female, most common allergens were nickel sulphate (65.2%) and fragrance mix (26.1%). In our study, majority of the allergens were positive. Hence, the ISS used in the study might be suitable in the context of Nepalese population. However, further similar studies on large number of patients with multiple allergens are required to determine the exact number of contact allergens prevalent in our population.


2020 ◽  
Vol 20 (7) ◽  
pp. 1003-1009
Author(s):  
Malena Gergovska ◽  
Razvigor Darlenski ◽  
Jana Kazandjieva

Background: Hypersensitization to nickel is one of the most common contact allergies in the modern world and it is considered to be a major cause of contact dermatitis, especially for hand eczema. Objective: The aim of this paper is to describe many faces of the nickel allergy and to find out different diagnostic, potential strategies for treatment and prevention in hypersensitized patients. A personal clinical experience with practical clinical cases of contact dermatitis to nickel has also been presented. Methods: Electronic databases on this topic was carried out using PubMed-Medline. Results: The literature review identified many articles reporting for nickel contact allergy and pointing the metal as number one allergen in the frequency of positive skin patch test reactions in a large population worldwide. Herein, a summary of the current understanding and evidence on nickel allergy with practical approach and proposed recommendations to the dermatologist, general practitioner, and the allergist were prepared. Conclusions: The prevalence of nickel allergy represents an important socio-economical and health issue. Metal is one of the most common sensitizing agents worldwide. The morbidity due to this metal represents the allergic contact dermatitis and it is constantly growing in many countries. There are also cases of systemic allergic contact dermatitis, where they could be easily misdiagnosed as adverse drug reactions, which lead to delay of the correct diagnosis and inappropriate treatment.


Sign in / Sign up

Export Citation Format

Share Document