Type III Endoleak from a Thoracic Aortic Stent-Graft

2002 ◽  
Vol 9 (4) ◽  
pp. 535-538 ◽  
Author(s):  
Conrad Lange ◽  
Asbjørn Ødegård ◽  
Jan Lundbom ◽  
Staal Hatlinghus ◽  
Hans O. Myhre

Purpose: To present an as yet unreported late complication of an Excluder thoracic endograft. Case Report: A 78-year-old man underwent surgery for a ruptured type V thoracoabdominal aortic aneurysm in 1996. Four years later, an aneurysm was detected in the proximal thoracic aorta and repaired with 2 Excluder endoprostheses. At 12 months, computed tomography showed an increase in the aneurysm sac diameter and a type III endoleak, which was traced to a hole in the stent-graft fabric on arteriography. No fracture of the metal components was detected in the stent-grafts. Another Excluder device was implanted within the distal endograft. Satisfactory exclusion of the leak has been maintained for 6 months. Conclusions: The risk of type III leaks must be minimized before stent-grafting can be regarded as a routine procedure in the treatment of thoracic aortic aneurysms.

Circulation ◽  
1999 ◽  
Vol 100 (suppl_2) ◽  
Author(s):  
Kanji Inoue ◽  
Hiroaki Hosokawa ◽  
Tomoyuki Iwase ◽  
Mitsuru Sato ◽  
Yuki Yoshida ◽  
...  

Background —Recently, thoracic aortic stent grafting has emerged as an alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. However, its application has been limited to descending thoracic aortic aneurysms distal to the aortic arch. We report our initial clinical experience of endovascular branched stent graft repair for aortic arch aneurysms. Methods and Results —Endovascular grafting with Inoue branched stent grafts was attempted for 15 patients with thoracic aortic aneurysms and aortic dissections under local anesthesia (n=14) or general anesthesia (n=1). Single-branched stent grafts were used in 14 patients, and a triple-branched stent graft in one. The branched stent grafts were delivered through a 22F or a 24F sheath under fluoroscopic guidance and implanted across the aneurysmal aortic arch. In 2 patients, the single-branched stent graft did not pass through the 22F sheath used. Complete thrombosis of the aneurysm was ultimately achieved in 11 patients (73%). Of 4 persistent leaks, 1 minor leak spontaneously thrombosed and 1 major leak was successfully treated by additional straight stent graft placement. In 1 patient, the right external iliac artery ruptured during the withdrawal of the sheath and was successfully repaired by the implantation of a straight stent graft. One patient with severe stenosis of the aortic graft section was successfully managed by additional stent deployment. Peripheral microembolization to a toe occurred in 1 patient, and cerebral infarction occurred in 1 other patient. Two patients who had failed to receive endovascular stent grafts died during an average follow-up of 12.6 months, 1 of pneumonia and the other of rupture of a concomitant abdominal aortic aneurysm. Conclusions —This report demonstrates the technical feasibility of endovascular branched stent graft repair for aneurysms located at the aortic arch. Careful, longer follow-up and further extensive clinical trials are awaited toward establishing this technique as a recommendable alternative to surgical treatment of thoracic aortic aneurysms.


Author(s):  
Hiroshi Ohtake ◽  
Keiichi Kimura ◽  
Go Watanabe ◽  
Junichiro Sanada ◽  
Osamu Matsui

Objective To obtain early MK stent-grafting results for nonruptured thoracic aortic aneurysms and thoracoabdominal aortic aneurysms. Methods The authors analyzed 47 patients who underwent treatment using MK stent-grafting. All patients (40 men and 7 women; mean age, 70.8 years) underwent elective procedures. Straight, curved, or tapered MK stents were constructed from a nitinol wire and covered with seamless, cylindrical woven polyester fabric grafts. The mean stent-graft diameter was 24 to 48 mm. In cases where the aneurysm had a short proximal neck (under 15 mm), supraaortic arch artery bypass surgery was planned to lengthen the neck. Results Simple stent-grafting without bypass was performed in 26 patients, whereas stent-grafting with supraaortic arch artery bypass was performed in 21 patients. An 18 or 20 F sheath was used as the delivery system in 46 patients (96%). In all 47 patients, the stent-grafts were successfully deployed. Two patients died while in hospital, and another 2 patients suffered a stroke. No other perioperative complications were observed. Postoperative computed tomography after 3 months showed complete thrombus formation in 42 patients (93.3%; 42/45 patients). Conclusions Forty-seven patients with thoracic aortic aneurysm were treated with our original flexible MK stent-graft system. Using a small sheath system, straight or curved M-K stent-grafts could be deployed to adequately fit to the aorta as planned. Furthermore, simultaneous bypass surgery widened the application of stent-grafting. However, careful long-term observation is necessary, and further studies are needed to assess such stent-grafting with bypass surgery.


1997 ◽  
Vol 2 (2) ◽  
pp. 98-103 ◽  
Author(s):  
Charles P Semba ◽  
R Scott Mitchell ◽  
D Craig Miller ◽  
Noriyuki Kato ◽  
Stephen T Kee ◽  
...  

The purpose of the study was to describe the clinical experience in using endoluminal stent-grafts for the treatment of thoracic aortic aneurysms in high-risk patients. Patients with aneurysms of the descending thoracic aorta who were considered high surgical risks underwent evaluation for endoluminal repair. The prosthesis was constructed from Z stents covered with polyester fabric using dimensions based upon preprocedural computed tomography scans and angiography. Through a femoral arteriotomy or left retroperitoneal flank incision, a 22–24 Fr delivery catheter was inserted and advanced through the aorta to the target site under fluoroscopic guidance in the operating suite. The stent-graft prosthesis was deployed at the site of the aneurysm. 44 patients (36 male, 8 female; mean age 36 years) underwent stent-graft repair for thoracic aneurysms (mean diameter 6.3 cm). The deployment was technically successful in all cases, with complete aneurysm thrombosis in 88%. The 30-day perioperative mortality rate was 6.8% and 35-month actuarial survival was 82%. There were no cases of stent migration, surgical conversion or intraprocedural death. Paraplegia occurred in two patients who underwent simultaneous surgical infrarenal aortic aneurysm repair immediately followed by stent-graft placement for a coexisting thoracic aneurysm. The conclusion was that placement of endoluminal stent-grafts for repair of thoracic aortic aneurysms is technically feasible in high-risk patients in whom conventional surgery is contraindicated. Long-term studies are needed to determine protection against aneurysm rupture and patient survival.


Vascular ◽  
2005 ◽  
Vol 13 (1) ◽  
pp. 5-10 ◽  
Author(s):  
Alfio Carroccio ◽  
David Spielvogel ◽  
Sharif H. Ellozy ◽  
Robert A. Lookstein ◽  
Iris Y. Chin ◽  
...  

Reconstruction of aortic arch and descending thoracic aortic aneurysms (TAAs) is technically challenging and associated with significant morbidity and mortality. We report our experience with extensive TAAs using a two-stage “elephant trunk” repair, with the second stage completed using an endovascular stent graft (ESG). Over 6 years, 111 patients underwent ESG treatment of TAAs at Mount Sinai Medical Center. Twelve of these patients were referred for ESG placement for the second stage of elephant trunk reconstruction because comorbidities placed them at high risk of open surgical repair. Our database was analyzed for technical and clinical success and perioperative complications. The mean follow-up was 11.8 months (range 1–64 months). Twelve patients (five women and seven men) with a mean age of 69 ± 10 years underwent repair of their distal aortic arch and descending TAAs. These aneurysms included nine atherosclerotic aneurysms, one pseudoaneurysm, and two penetrating atherosclerotic ulcers. Three patients were symptomatic. Stent graft repair was technically successful in 91.7% or 11 of 12 patients. Excessive aortic arch tortuosity resulted in failure to deploy a stent graft in one patient. An antegrade approach through the open elephant trunk was used in two patients with severe iliac occlusive disease. Endoleaks (type 2) were identified in two patients with no aneurysm expansion; however, a 14 mm expansion over 1 year occurred in a patient with no identifiable endoleak. One early mortality occurred in a patient with a ruptured 6 cm infrarenal AAA after successful exclusion of the 8 cm TAA. Second-stage elephant trunk reconstruction of an extensive TAA using an ESG is effective in the short term. Its long-term durability remains to be determined.


2020 ◽  
Vol 27 (5) ◽  
pp. 749-756
Author(s):  
Guangmin Yang ◽  
Ming Zhang ◽  
Mehmutjan Muzepper ◽  
Xiaolong Du ◽  
Wei Wang ◽  
...  

Purpose: To evaluate the immediate postoperative and midterm outcomes of complex thoracoabdominal aortic aneurysm (TAAA) treatment with fenestrated/branched physician-modified endovascular grafts (PMEGs) or open debranching of the visceral aorta with bypass graft revascularization plus endovascular aneurysm exclusion (hybrid repair). Materials and Methods: A retrospective analysis was conducted of 88 patients (mean age 70.0±10.6 years; 73 men) with complex TAAAs who underwent treatment with PMEGs (60, 68%) or a hybrid technique (28, 32%) between 2016 and 2019. The mean aneurysm diameter was 64.5±11.7 mm, and 37 patients (42%) were symptomatic. The Zenith TX2 and Ankura were the main stent-grafts used in the PMEG group. The hybrid technique involved visceral debranching with extra-anatomical bypass graft revascularization and subsequent stent-graft deployment (1- or 2-stage procedure). Results: In the PMEG group, 35 patients received modified stent-grafts with 4 fenestrations, 8 patients had 4 branches per device, and 17 patients had combinations (50 fenestrations and 18 branches) that successfully revascularized 228 of the 240 targets (95%). In the 28 hybrid cases, all 110 target vessels were successfully revascularized with bypass grafts. The overall 30-day mortality was 3.4% (2 PMEG and 1 hybrid), and the early rate of target vessel stenosis/occlusion was 3.3% (5 in PMEG group and 6 in the hybrid repair group). The 30-day morbidity was mainly attributed to pulmonary complications (15%), lower limb ischemia (8%), or spinal cord ischemia with paraplegia (6%). Eleven patients (13%) had deteriorated renal function with a >30% decrease in the glomerular filtration rate. The mean follow-up was 22.3±4.9 months, and mortality was 4.5% (3.3% in the PMEG group vs 7.1% in the hybrid repair group). Conclusion: PMEGs and hybrid techniques seem to be feasible treatment options for aortic aneurysms necessitating visceral vessel revascularization. PMEGs may have a lower morbidity than the hybrid technique, which nonetheless remains an important option available for complex aortic aneurysms.


2002 ◽  
Vol 9 (4) ◽  
pp. 535-538 ◽  
Author(s):  
Conrad Lange ◽  
Asbjørn Ødegård ◽  
Jan Lundbom ◽  
Staal Hatlinghus ◽  
Hans O. Myhre

Vascular ◽  
2020 ◽  
pp. 170853812098112
Author(s):  
Cassra N Arbabi ◽  
Navyash Gupta ◽  
Ali Azizzadeh

Objectives Thoracic endovascular aortic repair (TEVAR) is the standard of care for descending thoracic aortic aneurysms (DTAA), and newer generation stent grafts have significant design improvements compared to earlier generation devices. Methods We report the first commercial use of the Medtronic Valiant Navion stent graft for treatment of an 85-year-old woman with a 5.8 cm DTAA and a highly tortuous thoracic aorta. Results A percutaneous TEVAR was performed using a two-piece combination of the Valiant Navion FreeFlo and CoveredSeal stent graft configurations for zones 2–5 coverage. The devices were successfully delievered through highly tortuous anatomy and deployed, excluding the entire length of the aneurysm with precise landing, excellent apposition and no evidence of endoleak. The patient tolerated the procedure well and has had no stent graft-related complications through one-year follow-up. Conclusions Design enhancements such as a lower profile delivery system, better conformability, and a shorter tapered tip are some of the improvements to this third-generation TEVAR device. Coupled with the multiple configuration options available, this gives physicians a better tool to treat thoracic aortic pathologies in patients with challenging anatomy. The early results are encouraging, and evaluation of long-term outcomes will continue.