Early Results of a Novel Gutter-Free Chimney Stent-Graft System to Treat Aortic Arch Dissection: Single-Center Data from a Prospective Clinical Trial

2021 ◽  
pp. 152660282110456
Author(s):  
Chang Shu ◽  
Xin Li ◽  
Alan Dardik ◽  
Quanming Li ◽  
Hao He ◽  
...  

Aims: Discuss the clinical value, technique characteristics, and early follow-up results of a newly designed gutter-free chimney stent-graft system for aortic arch pathology. Methods and Results: About 13 patients with aortic arch dissection were enrolled in a clinical trial testing a novel gutter-free stent-graft between February 2019 and December 2020. All 13 patients were male, age 52.6±10.4 years. The implantation time was 14.0±6.9 minutes; total procedure time was 89.5±19.8 minutes. The volume of contrast was 79.6±7.2 ml. And 15 aortic stent-grafts were implanted, and all 13 patients had chimney branch stent-grafts implanted into the left subclavian artery (LSA). There were 3 (23.1%) cases of immediate type Ιa endoleak after thoracic endovascular aortic repair (TEVAR), and 7.7% type Ιa endoleaks occurred in delayed fashion. Survival at 2 years was 100%, and the 2-year patency of chimney stent-grafts was 100%. Conclusions: This study reports early success with good freedom from endoleak using a novel stent-graft designed for chimney TEVAR to treat aortic arch dissection. Postoperative survival and patency of the branch stent-grafts were excellent. Additional data from this multicenter clinical trial will be forthcoming.

2016 ◽  
Vol 24 (1) ◽  
pp. 97-106 ◽  
Author(s):  
Emma van der Weijde ◽  
Olaf J. Bakker ◽  
Ignace F. J. Tielliu ◽  
Clark J. Zeebregts ◽  
Robin H. Heijmen

Purpose: To report the perioperative results and short-term follow-up of patients treated with scalloped thoracic stent-grafts. Methods: A multicenter registry in the Netherlands captured data on 30 patients (mean age 68 years; 17 men) with thoracic aortic pathology and a short (<20 mm) proximal or distal landing zone who received a custom-made scalloped stent-graft between January 2013 and February 2016. Patients were treated for saccular (n=13) aneurysms, fusiform (n=9) aneurysms, pseudoaneurysms (n=4), or chronic type B dissections (n=4). The scallop was used to preserve flow in the left subclavian artery (LSA) (n=17), left common carotid artery (n=5), innominate artery (n=1), and celiac trunk (n=7). In 7 (23%) patients, the scallop also included the adjacent artery. Results: Technical success was achieved in 28 (93%) patients. In 1 patient, a minor type Ia endoleak was observed intraoperatively, which was no longer visible on computed tomography angiography at 3 months. In another patient, the LSA was unintentionally obstructed due to migration of the stent-graft on deployment. Concomitant carotid-carotid or carotid-subclavian bypass was performed in 4 patients. There was no retrograde type A dissection or conversion to open surgery. In-hospital mortality was 3%, and the perioperative ischemic stroke rate was 3%. At a mean follow-up of 9.7 months (range <1 to 31), 29 of 30 target vessels were patent. Conclusion: The scalloped stent-graft appears to be a safe and relatively simple alternative for the treatment of thoracic aortic lesions with short landing zones. Larger patient series and long-term follow-up are required to confirm these early results.


2021 ◽  
pp. 152660282110364
Author(s):  
Xiaoye Li ◽  
Lei Zhang ◽  
Chao Song ◽  
Hao Zhang ◽  
Shibo Xia ◽  
...  

Objectives This study evaluated the feasibility and safety of total endovascular aortic arch repair with surgeon-modified fenestrated stent-graft on zone 0 landing for aortic arch pathologies. Methods Between June 2016 and October 2019, 37 consecutive patients underwent total endovascular arch repair with surgeon-modified fenestrated stent-grafts on zone 0 landing. Outcomes included technical success, perioperative and follow-up morbidity and mortality, and branch artery patency. Results During the study period, 37 patients were treated with total endovascular aortic arch repair with surgeon-modified fenestrated stent-graft. Twenty-one (56.8%) patients were diagnosed with aortic dissections, 15 (40.5%) patients with aneurysms, and 1 (2.7%) patient required reintervention due to endoleak and sac expansion from previous thoracic endovascular aortic repair for thoracoabdominal aneurysm. The proximal landing zone for all patients were in zone 0, and all branch arteries of aortic arch were reconstructed. Technical success was achieved in 34 cases (91.9%). Three (8.1%) patients had fenestrations misaligned with target arteries, and the chimney technique was applied as a complementary measure. Thirty-day mortality rate was 5.4% (n=2). Thirty-day stroke rate was 5.4% (n=2). Thirty-day reintervention rate was 2.7% (n=1). At a median follow-up of 20 months (range, 3–49 months), 5 (13.5%) patients died, including 2 aortic-related deaths, 1 nonaortic-related death, and 2 deaths of unknown reason. One (2.7%) patient had stroke. Four patients (10.8%) had reintervention during the follow-up, including 2 cases of left subclavian artery occlusion and 2 cases of type II endoleak. The estimated survival (±SE) at 2 years was 72.4%±9.7% (95% CI 53.4%–91.4%). The estimated freedom from reintervention (±SE) at 2 years was 87.4%±5.9% (95% CI 75.84%–98.96%). Conclusions Total endovascular aortic arch repair with surgeon-modified fenestrated stent-grafts on zone 0 landing is an alternate option for the treatment of aortic arch pathologies in experienced centers.


2019 ◽  
Vol 26 (5) ◽  
pp. 645-651 ◽  
Author(s):  
Ludovic Canaud ◽  
Baris Ata Ozdemir ◽  
Lucien Chassin-Trubert ◽  
Julien Sfeir ◽  
Pierre Alric ◽  
...  

Purpose: To evaluate outcomes of homemade fenestrated stent-grafts for complete endovascular aortic repair of aortic arch dissections. Materials and Methods: From July 2014 through September 2018, 35 patients (mean age 66±11 years; 25 men) underwent homemade fenestrated stent-graft repair of acute (n=16) or chronic (n=10) complicated type B aortic dissections (n=16) and dissecting aortic arch aneurysms subsequent to surgical treatment of acute type A dissections (n=9). Nineteen (54%) procedures were emergent. Results: Zone 2 single-fenestrated stent-grafts were used in 25 cases; the remaining 10 were double-fenestrated stent-grafts deployed in zone 0. Median time for stent-graft modification was 18 minutes (range 16–20). Technical success was achieved in all cases. An immediate distal type I endoleak was treated intraoperatively. Among the double-fenestrated stent-graft cases, the left subclavian artery fenestration could not be cannulated in 2 patients and revascularization was required. Partial coverage of the left common carotid artery necessitated placement of a covered stent in 3 cases. One (3%) patient had a stroke without permanent sequelae. Two type II endoleaks required additional covered stent placement at 5 and 7 days postoperatively, respectively. The 30-day mortality was 6% (2 patients with ruptured aortic arch aneurysm). During a mean follow-up of 17.6±13 months, there was no aortic rupture or retrograde dissection. One late type I endoleak was treated with additional proximal fenestrated stent-graft placement. One type II endoleak is currently under observation. One additional patient died (unrelated to the aorta); overall mortality was 9%. All supra-aortic trunks were patent. Conclusion: The use of homemade fenestrated stent-grafts for endovascular repair of aortic arch dissections is feasible and effective for total endovascular aortic arch repair. Durability concerns will need to be assessed in additional studies with long-term follow-up.


2021 ◽  
pp. 153857442110104
Author(s):  
Xiaoye Li ◽  
Lei Zhang ◽  
Chao Song ◽  
Hao Zhang ◽  
Shibo Xia ◽  
...  

Objectives: To report outcomes of thoracic endovascular repair using customized single-branched fenestrated stent-grafts in treatment of aortic arch dissections. Materials and Methods: Between November 2009 and November 2011, 16 patients with aortic arch dissections underwent thoracic endovascular aortic repair utilizing customized unibody single-branched fenestrated stent-graft (UBFSG) in our institution. Results: All 16 patients were male with mean age of 54.50 ± 11.33. The technical success rate was 100%. 30-day mortality rate was 6.25% (n = 1). The median follow-up period was 98 months (range, 0-119). During follow-up, 4 nonaorta-related deaths were recorded. Two (2) cases of left subclavian artery occlusion were observed 12 and 14 months after the operation. Two (2) patients had another successful endovascular repair in time, including one case of type Ib endoleak occurred 100 months after the operation and one case of stent-graft induced new entry tear 38 months after the operation. No stroke and migration of stent-grafts were observed. Conclusions: The branched fenestrated stent-graft may be an effective alternative treatment for aortic arch dissections unfit for open surgery.


Circulation ◽  
1999 ◽  
Vol 100 (suppl_2) ◽  
Author(s):  
Kanji Inoue ◽  
Hiroaki Hosokawa ◽  
Tomoyuki Iwase ◽  
Mitsuru Sato ◽  
Yuki Yoshida ◽  
...  

Background —Recently, thoracic aortic stent grafting has emerged as an alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. However, its application has been limited to descending thoracic aortic aneurysms distal to the aortic arch. We report our initial clinical experience of endovascular branched stent graft repair for aortic arch aneurysms. Methods and Results —Endovascular grafting with Inoue branched stent grafts was attempted for 15 patients with thoracic aortic aneurysms and aortic dissections under local anesthesia (n=14) or general anesthesia (n=1). Single-branched stent grafts were used in 14 patients, and a triple-branched stent graft in one. The branched stent grafts were delivered through a 22F or a 24F sheath under fluoroscopic guidance and implanted across the aneurysmal aortic arch. In 2 patients, the single-branched stent graft did not pass through the 22F sheath used. Complete thrombosis of the aneurysm was ultimately achieved in 11 patients (73%). Of 4 persistent leaks, 1 minor leak spontaneously thrombosed and 1 major leak was successfully treated by additional straight stent graft placement. In 1 patient, the right external iliac artery ruptured during the withdrawal of the sheath and was successfully repaired by the implantation of a straight stent graft. One patient with severe stenosis of the aortic graft section was successfully managed by additional stent deployment. Peripheral microembolization to a toe occurred in 1 patient, and cerebral infarction occurred in 1 other patient. Two patients who had failed to receive endovascular stent grafts died during an average follow-up of 12.6 months, 1 of pneumonia and the other of rupture of a concomitant abdominal aortic aneurysm. Conclusions —This report demonstrates the technical feasibility of endovascular branched stent graft repair for aneurysms located at the aortic arch. Careful, longer follow-up and further extensive clinical trials are awaited toward establishing this technique as a recommendable alternative to surgical treatment of thoracic aortic aneurysms.


2018 ◽  
Vol 26 (1) ◽  
pp. 72-75
Author(s):  
Fabien Lareyre ◽  
Claude Mialhe ◽  
Carine Dommerc ◽  
Juliette Raffort

Purpose: To report the use of the Nellix endovascular aneurysm sealing (EVAS) system in the management of proximal stent-graft collapse associated with thrombosis following endovascular aneurysm repair (EVAR). Case Report: A 76-year-old man was admitted for proximal collapse of an aortic extension following bifurcated AFX stent-graft implantation associated with chimney grafts in both renal arteries and the superior mesenteric artery 1 month prior. Imaging identified thrombosis of the aortic stent-graft and the iliac limbs. A Nellix EVAS was placed into the AFX stent-graft to recanalize the aneurysm lumen and address the aortic thrombosis. There was no endoleak, and the renovisceral chimney stent-grafts remained patent over a follow-up of 25 months. Conclusion: While further studies are required to generalize its use, EVAS appears to be feasible in the management of aortic stent-graft collapse.


2009 ◽  
Vol 137 (1-2) ◽  
pp. 10-17 ◽  
Author(s):  
Lazar Davidovic ◽  
Momcilo Colic ◽  
Igor Koncar ◽  
Dejan Markovic ◽  
Dusan Kostic ◽  
...  

Introduction. Endovascular aneurysm repair (EVAR) has been introduced into clinical practice at the beginning of the 90's of the last century. Because of economic, political and social problems during the last 25 years, the introduction of this procedure in Serbia was not possible. Objective. The aim of this study was to present preliminary experiences and results of the Clinic for Vascular Surgery of the Serbian Clinical Centre in Belgrade in endovascular treatment of thoracic and abdominal aortic aneurysms. Methods. The procedure was performed in 33 patients (3 female and 30 male), aged from 42 to 83 years. Ten patients had a descending thoracic aorta aneurysm (three atherosclerotic, four traumatic - three chronic and one acute as a part of polytrauma, one dissected, two penetrated atherosclerotic ulcers), while 23 patients had the abdominal aortic aneurysm, one ruptured and two isolated iliac artery aneurysms. The indications for EVAR were isthmic aneurismal localisation, aged over 80 years and associated comorbidity (cardiac, pulmonary and cerebrovasular diseases, previous thoracotomy or multiple laparotomies associated with abdominal infection, idiopatic thrombocitopaenia). All of these patients had three or more risk factors. The diagnosis was established using duplex ultrasonography, angiography and MSCT. In the case of thoracic aneurysm, a Medtronic-Valiant? endovascular stent graft was implanted, while for the abdominal aortic aneurysm Medtronic-Talent? endovascular stent grafts with delivery systems were used. In three patients, following EVAR a surgical repair of the femoral artery aneurysm was performed, and in another three patients femoro-femoral cross over bypass followed implantation of aortouniiliac stent graft. Results. During procedure and follow-up period (mean 1.6 years), there were: one death, one conversion, one endoleak type 1, six patients with endoleak type 2 that disappeared during the follow-up period, one early graft thrombosis. No other complications, including aneurysm expansion, collapse, deformity and migration of the endovascular stent grafts, were registered. Conclusion. According to all medical and economic aspects, we recommend EVAR to treat acute traumatic thoracic aortic aneurysm, as well as in elderly and high-risk patients with abdominal or thoracic aneurysms, when open surgery is related to a significantly higher mortality and morbidity.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Juan Jose Rodriguez Arias ◽  
Josep Gomez-Lara ◽  
Juan Caballero-Borrego ◽  
Luis Ortega-Paz ◽  
Luis Teruel ◽  
...  

Background: Coronary vascular function of a chronic coronary total occlusion (CTO) immediately after recanalization is known to be poor and to be partially improved by pre-treatment with loading dose of ticagrelor vs. clopidogrel. It is unknown if this vascular dysfunction is maintained at long-term follow-up and may be improved by 1-year dual antiplatelet therapy (DAPT) with ticagrelor vs. clopidogrel. Methods: The TIGER is a prospective, open-label, two parallel-group controlled clinical trial, which 1:1 randomized 50 CTO patients to pre-PCI loading dose and subsequent 1-year DAPT with ticagrelor vs. clopidogrel. Coronary blood flow (CBF) under stepwise adenosine infusion was assessed after drug loading dose and at follow-up and compared between the two drug groups, adjusting for time of follow-up. Results: Out of 50 patients with index CBF evaluation, 38 (76%) patients underwent angiographic follow-up (23 and 15 at 1 and 3-year, respectively). A higher CBF area under the curve (AUC), already observed after loading dose in ticagrelor vs. clopidogrel group (p=0.027), was maintained at follow-up (AUC 34815.22±24206.06 vs. AUC 22712.47±13768.95; p=0.071). Specifically, whereas high ticagrelor loading dose-related CBF was sustained at follow-up (p=0.933), clopidogrel loading dose-related CBF increased at follow-up (p=0.039). Conclusion: The TIGER trial showed that DAPT with ticagrelor may maintain a higher CBF in a recanalized CTO as compared to clopidogrel, whose treated patients exhibit a lower CBF immediately after PCI with slight increase at follow-up. The clinical value of such sustained higher coronary flow should be evaluated in a larger group of patients.


2019 ◽  
Vol 53 (6) ◽  
pp. 515-519
Author(s):  
Toshiya Nishibe ◽  
Toru Iwahashi ◽  
Kentaro Kamiya ◽  
Masaki Kano ◽  
Keita Maruno ◽  
...  

We present 3 cases of type IIIb endoleak after endovascular aneurysm repair (EVAR) using the Zenith stent graft system. Type III endoleak, like type I endoleak, is a high-pressure, high-risk leak that increases sac pressure up to or even above arterial pressure, and is associated with an increased frequency of open conversions or risk of aneurysm rupture. Type IIIb endoleak is rare but there is much concern that the incidence of type IIIb endoleak is likely to increase hereafter; the mechanism of type IIIb endoleak is deterioration of graft fabric in conjunction with stent sutures. Type IIIb endoleak is difficult to diagnose before rupture. The possibility of type IIIb endoleak should be highly suspected when the continued growth of an excluded aneurysm sac without direct radiologic evidence is observed during follow-up. Type IIIb endoleak can be repaired by relining of the stent graft with additional stent grafts.


Aorta ◽  
2019 ◽  
Vol 07 (05) ◽  
pp. 129-136
Author(s):  
Abdullah Alhaizaey ◽  
Badr Aljabri ◽  
Musaad Alghamdi ◽  
Ali AlAhmari ◽  
Ahmed Abulyazied ◽  
...  

Abstract Background Endovascular stent grafting has emerged as an option to treat traumatic aorta injuries with reported significantly low mortality and morbidity. Stent collapse is one of the complications that can occur in this type of treatment. The aim of this article is to analyze the expected cause of stent collapse and to draw attention to the importance of the surveillance follow-up, as this phenomenon may occur late postdeployment. Methods A retrospectively collected dataset from the two highest volume trauma centers in Saudi Arabia was analyzed between April 2007 and October 2012. A total of 66 patients received stent grafts for traumatic aortic injury and were included in the study. We apply Ishimaru's anatomical aortic arch zones and Benjamin's aortic injury grading systems. There were 35 patients with aortic injury at zone 2, 26 patients in zone 3, and 5 patients in zone 4. About 96% (63) of the injuries were grades 2 and 3, including large intimal flap or aortic wall pseudoaneurysm with change in wall contour. The technical success rate, as defined by complete exclusion of lesions without leaks, stroke, arm ischemia or stent-related complications, was 90%. Results Proximal stent collapse occurred in 4.5% of patients (3 of 66 inserted stents) during follow-up of 4 to 8 years (mean, 6 years). Patients with stent collapse tended to have an acute aortic arch angle with long-intraluminal stent lip, when compared with patients with noncollapsed stents. Intraluminal lip protrusion more than 10-mm increased collapse (p < 0.001). Stent-grafts sizes larger than 28 mm also demonstrated a higher collapse rate (p < 0.001). Conclusions The risk of stent collapse appears related to poor apposition of the stent due to severe aortic arch angulation in young patients and to large stent sizes (>28 mm). Such age groups may have more anatomical and aortic size changes during the growth. Clinical and radiological surveillance is essential in follow-up after stent-graft treatment for traumatic aortic injury.


Sign in / Sign up

Export Citation Format

Share Document