Type IIIb Endoleak After Endovascular Aneurysm Repair Using the Zenith Stent Graft

2019 ◽  
Vol 53 (6) ◽  
pp. 515-519
Author(s):  
Toshiya Nishibe ◽  
Toru Iwahashi ◽  
Kentaro Kamiya ◽  
Masaki Kano ◽  
Keita Maruno ◽  
...  

We present 3 cases of type IIIb endoleak after endovascular aneurysm repair (EVAR) using the Zenith stent graft system. Type III endoleak, like type I endoleak, is a high-pressure, high-risk leak that increases sac pressure up to or even above arterial pressure, and is associated with an increased frequency of open conversions or risk of aneurysm rupture. Type IIIb endoleak is rare but there is much concern that the incidence of type IIIb endoleak is likely to increase hereafter; the mechanism of type IIIb endoleak is deterioration of graft fabric in conjunction with stent sutures. Type IIIb endoleak is difficult to diagnose before rupture. The possibility of type IIIb endoleak should be highly suspected when the continued growth of an excluded aneurysm sac without direct radiologic evidence is observed during follow-up. Type IIIb endoleak can be repaired by relining of the stent graft with additional stent grafts.

2018 ◽  
Vol 26 (1) ◽  
pp. 72-75
Author(s):  
Fabien Lareyre ◽  
Claude Mialhe ◽  
Carine Dommerc ◽  
Juliette Raffort

Purpose: To report the use of the Nellix endovascular aneurysm sealing (EVAS) system in the management of proximal stent-graft collapse associated with thrombosis following endovascular aneurysm repair (EVAR). Case Report: A 76-year-old man was admitted for proximal collapse of an aortic extension following bifurcated AFX stent-graft implantation associated with chimney grafts in both renal arteries and the superior mesenteric artery 1 month prior. Imaging identified thrombosis of the aortic stent-graft and the iliac limbs. A Nellix EVAS was placed into the AFX stent-graft to recanalize the aneurysm lumen and address the aortic thrombosis. There was no endoleak, and the renovisceral chimney stent-grafts remained patent over a follow-up of 25 months. Conclusion: While further studies are required to generalize its use, EVAS appears to be feasible in the management of aortic stent-graft collapse.


Vascular ◽  
2008 ◽  
Vol 16 (5) ◽  
pp. 253-257 ◽  
Author(s):  
Evert J. Waasdorp ◽  
Joost A. van Herwaarden ◽  
Rob H.W. van de Mortel ◽  
Frans L. Moll ◽  
Jean-Paul P.M. de Vries

This study evaluated the value of computed tomographic angiography (CTA) early after an endovascular aneurysm repair (EVAR) in relation to CTA 3 months after EVAR. We retrospectively reviewed all elective EVAR patients with available postprocedural and 3-month follow-up CTAs who were treated between 1996 and 2006. CTAs were analyzed for EVAR-related complications in terms of endoleaks, migration, and stent graft thrombosis. Secondary procedures and other complications within a 4-month time interval after EVAR were noted and analyzed for any association with the postprocedural CTA. During the study period, 291 patients (275 men), with a mean age of 71 years, underwent elective EVAR. All had postprocedural and 3-month follow-up CTAs, which detected 93 (32%) endoleaks (8 type I, 84 type II, 1 type III) and 1 stent graft thrombosis. These findings resulted in four secondary interventions (one interposition cuff, two extension cuffs, one conversion). All reinterventions were successfully done in an elective setting. During the first 3 postoperative months, five other reinterventions were required for acute ischemia in four patients (three Fogarty procedures, one femorofemoral crossover bypass) or groin infection in one patient. Eight patients died, but none of the deaths were related to abdominal aortic aneurysm or EVAR (four cardiac, two pulmonary, one gastric bleeding, one carcinoma). At 3 months, 43 endoleaks (3 type I, 40 type II), 3 stent graft thromboses, and 1 stent graft migration were seen. In two patients (0.7%), a new endoleak was diagnosed compared with the postprocedural CTAs. In 287 (99%) of 291 patients, the postprocedural CTA did not influence our treatment policy in the first 3 months after EVAR. More than half of the early endoleaks were self-limiting, and new endoleaks were seen in only two patients (< 1%) at the 3-month follow-up CTA. After an uneventful EVAR procedure, it is safe to leave out the early postprocedural CTA.


2021 ◽  
Vol 108 (Supplement_7) ◽  
Author(s):  
Arindam Chaudhuri ◽  
Ramita Dey ◽  
Weronika Stupalkowska

Abstract Aim Stent-grafts are finding a place in the treatment of femoral pseudoaneurysms (FpsAs), having been described in the treatment of infected pseudoaneurysms. We present the results of endovascular treatment of non-infected FpsAs using stent-grafts. Methods Case series of patients who underwent stent-graft coverage of FpsAs from January 2016 to December 2020. Stent-graft fractures, occlusions and reinterventions, length of stay (LOS) and 30-day mortality were assessed. Results 11 patients (mean age 75±10.3 years, 7 males; all ASA 3 or 4) underwent stent-graft coverage of FpsAs. Original procedures linked to the formation of FpsA were iliofemoral bypass (n = 3), femorofemoral crossover (n = 3), percutaneous coronary interventions (n = 2), aortobifemoral bypass (n = 1), endovascular aneurysm repair (n = 1) and femoral endarterectomy (n = 1). 3 patients had previous open FpsA repair. Technical success of deployment was 100%. Stent-grafts used included Viabahn Endoprosthesis (WL Gore & Associates, Flagstaff USA; n = 8), Viabahn VBX (WL Gore & Associates; n = 1) and BeGraft (Bentley InnoMed GmbH, Hechingen, Germany; n = 2). All patients were maintained on either antiplatelets or anticoagulant. 10 patients were available for analysis (1 lost to follow-up); radiological follow-up included initial computed tomography angiography and later combined duplex ultrasonography/plain radiography. Median LOS was 4 days (IQR 4). 30-day mortality was 0%. Median survival was 12 months (IQR 17). There was one stent-graft occlusion requiring thrombectomy but no fractures were observed in this series. Conclusions This small series suggests that there may be a role for stent-grafts in treatment of FpsAs in carefully selected patients. Given lack of data on long-term outcomes, continued surveillance is recommended.


Vascular ◽  
2017 ◽  
Vol 26 (3) ◽  
pp. 278-284 ◽  
Author(s):  
VP Bastiaenen ◽  
MGJ Snoeijs ◽  
JGAM Blomjous ◽  
J Bosma ◽  
VJ Leijdekkers ◽  
...  

Objectives Stent grafts for endovascular repair of infrarenal aneurysms are commercially available for aortic necks up to 32 mm in diameter. The aim of this study was to evaluate the feasibility of endovascular repair with large thoracic stent grafts in the infrarenal position to obtain adequate proximal seal in wider necks. Methods All patients who underwent endovascular aneurysm repair using thoracic stent grafts with diameters greater than 36 mm between 2012 and 2016 were included. Follow-up consisted of CT angiography after six weeks and annual duplex thereafter. Results Eleven patients with wide infrarenal aortic necks received endovascular repair with thoracic stent grafts. The median diameter of the aneurysms was 60 mm (range 52–78 mm) and the median aortic neck diameter was 37 mm (range 28–43 mm). Thoracic stent grafts were oversized by a median of 14% (range 2–43%). On completion angiography, one type I and two type II endoleaks were observed but did not require reintervention. One patient experienced graft migration with aneurysm sac expansion and needed conversion to open repair. Median follow-up time was 14 months (range 2–53 months), during which three patients died, including one aneurysm-related death. Conclusions Endovascular repair using thoracic stent grafts for patients with wide aortic necks is feasible. In these patients, the technique may be a reasonable alternative to complex endovascular repair with fenestrated, branched, or chimney grafts. However, more experience and longer follow-up are required to determine its position within the endovascular armamentarium.


2019 ◽  
Vol 26 (5) ◽  
pp. 645-651 ◽  
Author(s):  
Ludovic Canaud ◽  
Baris Ata Ozdemir ◽  
Lucien Chassin-Trubert ◽  
Julien Sfeir ◽  
Pierre Alric ◽  
...  

Purpose: To evaluate outcomes of homemade fenestrated stent-grafts for complete endovascular aortic repair of aortic arch dissections. Materials and Methods: From July 2014 through September 2018, 35 patients (mean age 66±11 years; 25 men) underwent homemade fenestrated stent-graft repair of acute (n=16) or chronic (n=10) complicated type B aortic dissections (n=16) and dissecting aortic arch aneurysms subsequent to surgical treatment of acute type A dissections (n=9). Nineteen (54%) procedures were emergent. Results: Zone 2 single-fenestrated stent-grafts were used in 25 cases; the remaining 10 were double-fenestrated stent-grafts deployed in zone 0. Median time for stent-graft modification was 18 minutes (range 16–20). Technical success was achieved in all cases. An immediate distal type I endoleak was treated intraoperatively. Among the double-fenestrated stent-graft cases, the left subclavian artery fenestration could not be cannulated in 2 patients and revascularization was required. Partial coverage of the left common carotid artery necessitated placement of a covered stent in 3 cases. One (3%) patient had a stroke without permanent sequelae. Two type II endoleaks required additional covered stent placement at 5 and 7 days postoperatively, respectively. The 30-day mortality was 6% (2 patients with ruptured aortic arch aneurysm). During a mean follow-up of 17.6±13 months, there was no aortic rupture or retrograde dissection. One late type I endoleak was treated with additional proximal fenestrated stent-graft placement. One type II endoleak is currently under observation. One additional patient died (unrelated to the aorta); overall mortality was 9%. All supra-aortic trunks were patent. Conclusion: The use of homemade fenestrated stent-grafts for endovascular repair of aortic arch dissections is feasible and effective for total endovascular aortic arch repair. Durability concerns will need to be assessed in additional studies with long-term follow-up.


2018 ◽  
Vol 25 (4) ◽  
pp. 480-491 ◽  
Author(s):  
Maaike A. Koenrades ◽  
Almar Klein ◽  
Anne M. Leferink ◽  
Cornelis H. Slump ◽  
Robert H. Geelkerken

Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17–47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. Results: At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). Conclusion: Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.


Vascular ◽  
2016 ◽  
Vol 25 (1) ◽  
pp. 92-100 ◽  
Author(s):  
Yang Yaoguo ◽  
Chen Zhong ◽  
Kou Lei ◽  
Xiao Yaowen

Objective We reviewed data pertaining to fenestrated endograft technique and chimney stent repair of complex aortic aneurysm for comparative analysis of the outcomes. Methods A comprehensive search of relevant databases was conducted to identify articles in English, related to the treatment of complex aortic aneurysm with fenestrated endovascular aneurysm repair and chimney stent repair, published until January 2015. Results A total of 42 relevant studies and 2264 patients with aortic aneurysm undergoing fenestrated endovascular aneurysm repair and chimney stent repair were included in our review. A total of 4413 vessels were involved in these processes. The cumulative 30-day mortality was 2.4% and 3.2% ( p = 0.459). The follow-up aneurysm-related mortality was 1.4% and 3.2% ( p = 0.018), and target organ dysfunction was 5.0% and 4.0% in fenestrated endovascular aneurysm repair and chimney stent repair, respectively ( p = 0.27). A total of 156 vessels showed restenosis or occlusion after primary intervention (3.6% and 3.4% in fenestrated endovascular aneurysm repair and chimney stent repair, respectively, p = 0.792). The cumulative type I endoleak was 2.0% (38/1884) after fenestrated endovascular aneurysm repair compared with 3.4% (13/380) after chimney stent repair ( p = 0.092), and the type II endoleak was 5.4% (102/1884) and 5.3% (20/380), respectively ( p = 0.905). Approximately, 1.1% and 1.6% increase in aneurysm was observed following fenestrated endovascular aneurysm repair and chimney stent repair, respectively ( p = 0.437). The re-intervention frequency was 205 and 19 cases after fenestrated endovascular aneurysm repair and chimney stent repair, respectively (11.7%, 5.6%, p = 0.001). Conclusions Fenestrated endovascular aneurysm repair and chimney stent repair are safe and effective in treating patients with complex aortic aneurysm. A higher aneurysm-related mortality was observed in chimney stent repair while fenestrated endovascular aneurysm repair was associated with a higher re-intervention rate.


2020 ◽  
Vol 27 (3) ◽  
pp. 462-467
Author(s):  
Konstantinos Tigkiropoulos ◽  
Kyriakos Stavridis ◽  
Ioannis Lazaridis ◽  
Evangelos Bontinis ◽  
Ioulia Zournatzi ◽  
...  

Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50–90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14–141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.


2018 ◽  
Vol 25 (6) ◽  
pp. 726-734 ◽  
Author(s):  
Raman Uberoi ◽  
Carlo Setacci ◽  
Mario Lescan ◽  
Antonio Lorido ◽  
David Murray ◽  
...  

Purpose: To evaluate the safety and performance of the Treovance stent-graft. Methods: The global, multicenter RATIONALE registry ( ClinicalTrials.gov; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. Results: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. Conclusion: The RATIONALE registry showed favorable safety and clinical performance of the Treovance stent-graft for the treatment of infrarenal AAAs in a real-world setting.


Author(s):  
Xuelian Gu ◽  
Kai Yu ◽  
Licheng Lu ◽  
Wenjing Tang

Endovascular aneurysm repair (EVAR) techniques have been widely used for the treatment of abdominal aortic aneurysm (AAA). EVAR is associated with lower postoperative morbidity and mortality than traditional surgical procedure to treat AAA [1]. However, during the patient’s follow-up, postoperative complications may occur and secondary interventions are required [2]. Stent-grafts fixation in the vessel affects the success of endovascular aneurysm repair. Researches indicate that insufficient stent-graft radial force is attributed to post-surgery complications, such as prosthesis migration and endoleak type I [3, 4]. Endoleak type I happens when there is not a complete contact between stent graft rings and vessel wall. A great radial force can prevent full obturation in the landing zone. The distal endograft fixation also has a great influence on proximal endograft migration after EVAR [5]. Therefore the radial force of the stent plays a significant role. Single stent-graft ring comprise a series of expandable Z-shaped structural elements (known as “struts”). Currently, there are series of Z-shaped stent-grafts on the market and the struts number ranges from 5 to 12. This work intends to analyze the influence of stent-graft struts number on the radial force. Finite-element analysis (FEA) and experimental method are used.