scholarly journals Woven EndoBridge Device immediate post-detachment tilt with later displacement: Case report, rescue techniques, and review of the literature

2020 ◽  
Vol 26 (4) ◽  
pp. 483-487
Author(s):  
Fortunato Di Caterino ◽  
Panagiotis Primikiris ◽  
Giovanni Vitale ◽  
Alessandra Biondi

The Woven EndoBridge Device (WEB) is efficient and safe in the treatment of wide-neck bifurcation intracranial aneurysms. A crucial step in operative planning is establishing the appropriate dimension of the device, and there are limitations to the therapeutic solutions provided by WEBs. We describe a case of a right middle cerebral artery bifurcation wide-neck aneurysm treated with WEB. After the initial deployment of a WEB proven oversized, we substituted it with a smaller one that presented immediate post-detachment intra-aneurysmal tilt probably resulting from undersizing. The 24-h angiographic control identified a partial displacement of the device in the superior middle cerebral artery branch. We describe rescue techniques with review of the literature and our treatment strategy, including effort to reposition the device followed by stent deployment. The treatment was electively completed by the coil-through technique. The post-detachment WEB tilt should be considered an unstable position and treated either by removal of the device or with adjunctive implants. Each WEB size adapts to a range of aneurysmal height and width. This range is not always the same for each specific WEB dimension, based on the table provided by the manufacturer. This eventually predisposes to a different behavior of different WEB sizes regarding the modification of the device’s height in relation to the modification of the diameter after deployment.

2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
David R. Santiago-Dieppa ◽  
Jeffrey S. Pannell ◽  
Alexander A. Khalessi

Middle cerebral artery (MCA) aneurysms are common entities, and those of the bifurcation are the most frequently encountered sublocation of MCA aneurysm. MCA bifurcation (MBIF) aneurysms commonly present with subarachnoid hemorrhage (SAH), are devastating, and are often lethal. At the present time, the treatment of ruptured MBIF aneurysms entails either endovascular or open microneurosurgical methods to permanently secure the aneurysm(s). The purpose of this report is to review the current available data regarding the relative superiority of endovascular versus open microneurosurgical clipping for the treatment of ruptured middle cerebral artery bifurcation aneurysms.


2018 ◽  
Vol 11 (1) ◽  
pp. 31-36 ◽  
Author(s):  
Reade A De Leacy ◽  
Kyle M Fargen ◽  
Justin R Mascitelli ◽  
Johanna Fifi ◽  
Lena Turkheimer ◽  
...  

Background and purposeBRANCH (wide-neck bifurcation aneurysms of the middle cerebral artery and basilar apex treated by endovascular techniques) is a multicentre, retrospective study comparing core lab evaluation of angiographic outcomes with self-reported outcomes.Materials and methodsConsecutive patients were enrolled from 10 US centres, aged between 18 and 85 with unruptured wide-neck middle cerebral artery (MCA) or basilar apex aneurysms treated endovascularly. Patient demographics, aneurysm morphology, procedural information, mortality and morbidity data and core lab and self-reported modified Raymond Roy (RR) outcomes were obtained.Results115 patients met inclusion criteria. Intervention-related mortality and significant morbidity rates were 1.7% (2/115) and 5.8% (6/103) respectively. Core lab adjudicated RR1 and 2 occlusion rates at follow-up were 30.6% and 32.4% respectively. The retreatment rate within the follow-up window was 10/115 (8.7%) and in stent stenosis at follow-up was 5/63 (7.9%). Self-reporting shows a statistically significant direction to angiographic RR one outcomes at follow-up compared with core lab evaluation, with OR 1.75 (95% CI 1.08 to 2.83).ConclusionEndovascular treatment of wide-neck MCA and basilar apex aneurysms resulted in a core lab adjudicated RR1 occlusion rate of 30.6%. Self-reported results at follow-up favour better angiographic outcomes, with OR 1.75 (95% CI 1.08 to 2.83). These data demonstrate the need for novel endovascular devices specifically designed to treat complex intracranial aneurysms, as well as the importance of core lab adjudication in assessing outcomes in such a trial.


Neurosurgery ◽  
2004 ◽  
Vol 54 (3) ◽  
pp. 667-671 ◽  
Author(s):  
Mehmet Erkan Üstün ◽  
Mustafa Büyükmumcu ◽  
Cagatay Han Ulku ◽  
Aynur Emine Cicekcibasi ◽  
Hamdi Arbag

Abstract OBJECTIVE In this study, we aimed to investigate the use of a radial artery graft for bypass of the maxillary artery (MA) to the proximal middle cerebral artery (MCA) as an alternative to superficial temporal artery-to-MCA anastomosis or extracranial carotid-to-MCA bypass using long grafts. METHODS Five adult cadavers were used bilaterally. After a frontotemporal craniotomy and a zygomatic arch osteotomy, the MA was found easily 1 to 2 cm inferior to the infratemporal crest. A hole was created with a 4-mm-tip drill in the sphenoid bone 2 to 3 mm lateral to the foramen rotundum extradurally, and the dura over the hole was opened. After the carotid and sylvian cisterns had been opened, the M2 segment of the MCA was exposed. The graft was passed through the hole to reach the M2 segment. Then, the MA was freed from the surrounding tissue and was transected before the infraorbital artery branch. The radial artery graft was anastomosed end-to-end to the MA proximally and end-to-side to the M2 segment of the MCA distally. RESULTS The mean thickness of the MA before the infraorbital artery branch was 2.6 ± 0.3 mm. The mean thickness of the largest trunk of the MCA was 2.3 ± 0.3 mm. The average length of the graft was 36 ± 5.5 mm. CONCLUSION MA-to-MCA bypass is as feasible as proximal MCA revascularization using long vein grafts. The thickness of the MA provides sufficient flow; the length of the graft is short, and it has a straight course. MA-to-proximal MCA bypass may be an alternative to superficial temporal artery-to-MCA as well as extracranial carotid-to-MCA bypasses.


1979 ◽  
Vol 50 (4) ◽  
pp. 522-524 ◽  
Author(s):  
Shiro Waga ◽  
Atsunori Morikawa ◽  
Tadashi Kojima

✓ A patient is reported with a purely pial arteriovenous malformation (AVM) supplied from the posterior parietal artery. The prominent middle meningeal artery contributed to opacification of the angular branches distal to the AVM, but did not contribute to the AVM. After total removal of the AVM, the angular branches became opacified from the middle cerebral artery. Review of the literature suggests that hypertrophied dural arteries which do not contribute to the AVM's but which do opacify the cortical branches distal to the AVM's are rare.


Neurosurgery ◽  
2017 ◽  
Vol 80 (6) ◽  
pp. 925-933 ◽  
Author(s):  
Benjamin Gory ◽  
Marta Aguilar-Pérez ◽  
Elisa Pomero ◽  
Francis Turjman ◽  
Werner Weber ◽  
...  

Abstract BACKGROUND: Bifurcation middle cerebral artery (MCA) aneurysms with wide neck are amenable to endovascular coiling with pCONus stent, a recent device dedicated to wide-neck bifurcation intracranial aneurysms. OBJECTIVE: To evaluate the 1-year angiographic follow-up of wide-neck MCA aneurysms treated with pCONus. METHODS: Forty MCA aneurysms (mean dome size, 7.7 mm; mean neck size, 5.6 mm) coiled with pCONus were retrospectively evaluated. “Recanalization” was defined as worsening, and “progressive thrombosis” was defined as improvement on the Raymond scale. RESULTS: Angiographic midterm (mean, 11.9 months; range, 3-20) follow-up was obtained in all aneurysms. Retreatment was performed in 9 aneurysms (22.5%) without clinical complications, and postoperative angiographic outcome included 2 complete occlusions and 7 neck remnants. Six aneurysms were followed after retreatment (mean, 8.8 months), and presented complete occlusion in 1 case, neck remnant in 4 cases, and aneurysm remnant in 1 case. Among the 31 aneurysms, follow-up showed complete occlusion in 67.7% (21/31), neck remnants in 29% (9/31), and aneurysm remnants in 3.3% (1/31). Adequate aneurysm occlusion (total occlusion and neck remnant) was obtained in 96.7% (30/31). Among these 31 aneurysms, improvement of the rate of occlusion was observed in 15 aneurysms (48.4%), and recurrence in 2 aneurysms (6.5%). There was no 1-year angiographic recurrence of 3- or 6-month totally occluded aneurysms. CONCLUSION: pCONus stent allows a safe coiling of wide-neck MCA aneurysms usually considered as surgical with a low recanalization rate for those adequately occluded at 3 to 6 months. Angiographic results improve over time due to progressive aneurysm thrombosis in around 50% of cases.


Neurosurgery ◽  
2012 ◽  
Vol 71 (6) ◽  
pp. 1185-1191 ◽  
Author(s):  
Young Dae Cho ◽  
Hyun-Seung Kang ◽  
Jeong Eun Kim ◽  
Young Je Son ◽  
Jong Young Lee ◽  
...  

ABSTRACT BACKGROUND: Protection techniques using stents or microcatheters allow treatment of aneurysms with complex configurations by coil embolization. However, the application of these techniques is occasionally limited in wide-neck middle cerebral artery (MCA) aneurysms with acute angularity of the efferent branch vessel. OBJECTIVE: We describe a looping technique for passage of a microcatheter and microwire into the acutely angled efferent branch vessel without navigating the system through the aneurysm lumen. METHODS: To select the acutely angulated branch, a looped microcatheter was advanced near the orifice of the distal acutely angled branch vessel, followed by microwire passage through the looped microcatheter into the efferent vessel. The microcatheter loop was straightened after the microwire had been sufficiently advanced. The microcatheter was then navigated into the distal branch vessel over the advanced microwire. RESULTS: A total of 36 wide-neck MCA aneurysms were successfully treated using this looping method. This technique was used to pass the microcatheter for stent protection in 13 patients and for microcatheter protection in 23. The method was most commonly used for aneurysms located at the M1 trunk (n = 21), followed by the MCA bifurcation (n = 15). Complete or near-complete endosaccular occlusion was achieved in 31 aneurysms. There were no complications related to looping the microcatheter. CONCLUSION: This microcatheter looping technique facilitates safe entry into the distal branch during coil embolization of wide-neck MCA aneurysms incorporating the origins of acutely angulated branches.


Sign in / Sign up

Export Citation Format

Share Document