scholarly journals Glenoid vault perforation in total shoulder arthroplasty: Do we need computer guidance?

2019 ◽  
pp. 175857321988506
Author(s):  
Jennifer N Flynn ◽  
Malin Wijeratna ◽  
Matthew Evans ◽  
Steven Lee ◽  
David McD Taylor ◽  
...  

The proliferation of computer 3D simulation and computer-generated guides is aimed at minimizing perforation of the glenoid vault by glenoid pegs in shoulder arthroplasty, based on assumptions that perforation leads to worse outcomes by component loosening and potential failure. We evaluated outcomes of glenoid peg perforation testing the assumption that perforation produces worse results. Eighty-three shoulders underwent shoulder arthroplasty with pegged hybrid fixation (bone-ingrowth flanged central glenoid peg and peripheral cemented pegs) without precision signal injector guides or use of 3D planning software. Outcomes were determined by American Shoulder and Elbow Score and Oxford Shoulder Score. Fine slice CT determined the presence of vault perforation and the extent of lucent lines at the prosthesis–bone interface and bony morphology of the vault perforation. Follow-up was 46.7 months (24–99). Seven shoulders (8%) demonstrated perforation of glenoid vault. Bony ingrowth and cortical overgrowth occurred despite perforation, with no clinically significant differences in clinical or radiological outcomes in shoulders with and without glenoid vault perforation. None of these patients underwent revision surgery. Despite not utilizing computer planning and/or guides, 92% of implants did not perforate the glenoid vault. However, glenoid vault perforation in our series produced excellent outcomes with no increased risk of revision as a result of glenoid vault perforation.

Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


2021 ◽  
pp. 155633162110408
Author(s):  
Ahmed Haleem ◽  
Phelopater Sedrak ◽  
Chetan Gohal ◽  
George S. Athwal ◽  
Moin Khan ◽  
...  

Background: Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. Questions/Purpose: We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. Methods: PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. Results: Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. Conclusion: Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.


2018 ◽  
Vol 2 ◽  
pp. 247154921880777
Author(s):  
Zachary J Bloom ◽  
Cesar D Lopez, BA ◽  
Stephen P Maier ◽  
Brian B Shiu ◽  
Djuro Petkovic ◽  
...  

Introduction Lesser tuberosity osteotomy (LTO) during anatomic total shoulder arthroplasty has a 13% nonunion rate. Treatment for LTO nonunion is controversial and poorly described in the literature. The purpose of this study was to compare the surgical and nonsurgical treatment outcomes of LTO nonunion. Methods A retrospective case series of 9 consecutive patients with LTO nonunion after primary anatomic shoulder arthroplasty at 1 institution from 2010 to 2016 were studied. Outcomes measured were radiographic evaluation of LTO on axillary X-ray, clinical range of motion (ROM), subscapularis strength, and pain at the time of LTO nonunion diagnosis and after either conservative care or surgical repair of the LTO nonunion. Results LTO nonunion was treated surgically in 4 and conservatively in 5 patients with average follow-up of 30 and 22 months, respectively. There were no significant differences in age, sex, or smoking status between groups. Treatment decision was a shared model of surgeon and patient. Displaced LTO nonunion was treated surgically in 2 and conservatively in 3 patients. There were no differences in LTO union rate of 50% in the surgical versus 60% in the conservative group. Abdominal compression test was abnormal in 50% of surgical versus 40% of conservative groups. At follow-up, ROM was lower in the surgical group with 128° forward elevation (FE) and 33° external rotation (ER) compared to 148° FE and 62° ER. Only 1 patient with LTO nonunion required conversion to reverse replacement. Conclusion LTO nonunion after shoulder arthroplasty is rare. Surgical repair of LTO nonunion does not significantly improve clinical or radiographic outcomes compared to conservative care.


2021 ◽  
Vol 1 (3) ◽  
pp. 263502542199712
Author(s):  
Jordan D. Walters ◽  
Stephen F. Brockmeier

Background: This technique video reviews anatomic total shoulder arthroplasty (TSA) with a stemless humeral component using a representative case example. Indications: Stemless TSA is indicated for patients with symptomatic glenohumeral arthritis typically younger than 65 years of age. Stemless TSA may be used for other glenohumeral degenerative conditions such as avascular necrosis or posttraumatic arthropathy, provided acceptable humeral bone quality is confirmed intraoperatively using a thumb-press test. Poor bone quality is the primary contraindication. Technique Description: Preoperatively, computed tomography is typically used for planning, and intraoperative navigation through magnetic resonance imaging is also useful. The procedure’s critical elements include beach chair positioning, standard deltopectoral approach with lesser tuberosity osteotomy (LTO), freehand proximal humeral osteotomy, perpendicular proximal humeral exposure and subsequent preparation over a central guidewire, stemless implant and humeral head sizing, perpendicular glenoid exposure and implant placement, and final humeral implantation with LTO repair/fixation. A phased rehabilitation protocol includes 6-week sling immobilization to protect the subscapularis/LTO repair and return to normal activities between 3 and 6 months postoperatively. Discussion/Conclusion: Stemless TSA shows promising early and mid-term outcomes with complication rates, including humeral loosening rates, similar to standard stemmed components. Potential complications include neurovascular injury, infection, glenoid or humeral component loosening, and rotator cuff failure.


2018 ◽  
Vol 100-B (6) ◽  
pp. 761-766 ◽  
Author(s):  
M. Holschen ◽  
M-K. Siemes ◽  
K-A. Witt ◽  
J. Steinbeck

Aims The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA. Material and Methods A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs. Results At final follow-up, the mean ASES was 59 (25 to 97) and the mean adjusted Constant Score was 63% (23% to 109%). Both improved significantly (p < 0.001). The mean forward flexion was 104° (50° to 155°) and mean abduction was 98° (60° to 140°). Nine patients (32%) had a complication; two had an infection and instability, respectively; three had a scapular fracture; and one patient each had delayed wound healing and symptomatic loosening. If implants could be converted to a rTSA without removal of the stem, the operating time was shorter (82 minutes versus 102 minutes; p = 0.018). Conclusion After failure of a HA in the treatment of a proximal humeral fracture, conversion to a rTSA may achieve pain relief and improved shoulder function. The complication rate is considerable. Cite this article: Bone Joint J 2018;100-B:761–6.


2018 ◽  
Vol 11 (2) ◽  
pp. 140-148 ◽  
Author(s):  
Alessandro Castagna ◽  
Raffaele Garofalo

Anatomic total shoulder arthroplasty (TSR) has been shown to generate good to excellent results for patients with osteoarthritis and a functioning rotator cuff. Many studies have reported that the glenoid component loosening and failure remain the most common long-term complication of total shoulder arthroplasty. The approach to glenoid component is critical because a surgeon should consider patient-specific anatomy, preserving bone stock and joint line restoration, for a good and durable shoulder function. Over the years, different glenoid design and materials have been tried in various configurations. These include cemented polyethylene, uncemented metal-backed and hybrid implants. Although advances in biomechanics, design and tribology have improved our understanding of the glenoid, the journey of the glenoid component in anatomic total shoulder arthroplasty has not yet reached its final destination. This article attempts to describe the evolution of the glenoid component in anatomic TSR and current practice.


2021 ◽  
Vol 24 (3) ◽  
pp. 125-134
Author(s):  
Kirtan Tankshali ◽  
Dong-Whan Suh ◽  
Jong-Hun Ji ◽  
Chang-Yeon Kim

Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up.Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with a minimum of 2 years of follow-up were enrolled. We evaluated the preoperative and postoperative clinical outcomes, radiological outcomes (notching and loosening), and complications of BIO-RSA at the last follow-up. In addition, we divided these patients into notching and not-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients between the two groups.Results: Visual analog scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles, and Simple Shoulder Test scores improved significantly from preoperative (average: 5, 39.43, 16.22, 3.94) to postoperative (average: 1.71, 78.91, 28.34, 7.8; p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20/38 patients (53%). In the comparison between notching and not-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications were three metaphyseal fractures and one inferior screw malposition. Postoperative complications included one heterotopic ossification, one scapula neck stress fracture, one humeral stem loosening, and one late infection.Conclusions: BIO-RSA resulted in improved clinical outcomes at mid-term follow-up in the Asian population. Although better cosmesis and advantages of glenoid lateralization were observed, we observed higher rates of scapular notching compared to previously reported rates in BIO-RSA studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.


Sign in / Sign up

Export Citation Format

Share Document