scholarly journals Treatment Outcomes of Lesser Tuberosity Osteotomy Nonunion After Total Shoulder Arthroplasty

2018 ◽  
Vol 2 ◽  
pp. 247154921880777
Author(s):  
Zachary J Bloom ◽  
Cesar D Lopez, BA ◽  
Stephen P Maier ◽  
Brian B Shiu ◽  
Djuro Petkovic ◽  
...  

Introduction Lesser tuberosity osteotomy (LTO) during anatomic total shoulder arthroplasty has a 13% nonunion rate. Treatment for LTO nonunion is controversial and poorly described in the literature. The purpose of this study was to compare the surgical and nonsurgical treatment outcomes of LTO nonunion. Methods A retrospective case series of 9 consecutive patients with LTO nonunion after primary anatomic shoulder arthroplasty at 1 institution from 2010 to 2016 were studied. Outcomes measured were radiographic evaluation of LTO on axillary X-ray, clinical range of motion (ROM), subscapularis strength, and pain at the time of LTO nonunion diagnosis and after either conservative care or surgical repair of the LTO nonunion. Results LTO nonunion was treated surgically in 4 and conservatively in 5 patients with average follow-up of 30 and 22 months, respectively. There were no significant differences in age, sex, or smoking status between groups. Treatment decision was a shared model of surgeon and patient. Displaced LTO nonunion was treated surgically in 2 and conservatively in 3 patients. There were no differences in LTO union rate of 50% in the surgical versus 60% in the conservative group. Abdominal compression test was abnormal in 50% of surgical versus 40% of conservative groups. At follow-up, ROM was lower in the surgical group with 128° forward elevation (FE) and 33° external rotation (ER) compared to 148° FE and 62° ER. Only 1 patient with LTO nonunion required conversion to reverse replacement. Conclusion LTO nonunion after shoulder arthroplasty is rare. Surgical repair of LTO nonunion does not significantly improve clinical or radiographic outcomes compared to conservative care.

2021 ◽  
pp. 175857322110588
Author(s):  
William R Aibinder ◽  
Fares Uddin ◽  
Ryan T Bicknell ◽  
Ryan Krupp ◽  
Markus Scheibel ◽  
...  

Background Finite element analysis has suggested that stemless implants may theoretically decrease stress shielding. The purpose of this study was to assess the radiographic proximal humeral bone adaptations seen following stemless anatomic total shoulder arthroplasty. Methods A retrospective review of 152 prospectively followed stemless total shoulder arthroplasty utilizing a single implant design was performed. Anteroposterior and lateral radiographs were reviewed at standard time points. Stress shielding was graded as mild, moderate, and severe. The effect of stress shielding on clinical and functional outcomes was assessed. Also, the influence of subscapularis management on the occurrence of stress shielding was determined. Results At 2 years postoperatively, stress shielding was noted in 61 (41%) shoulders. A total of 11 (7%) shoulders demonstrated severe stress shielding with 6 occurring along the medial calcar. There was one instance of greater tuberosity resorption. At the final follow-up, no humeral implants were radiographically loose or migrated. There was no statistically significant difference in clinical and functional outcomes between shoulders with and without stress shielding. Patients undergoing a lesser tuberosity osteotomy had lower rates of stress shielding, which was statistically significant ( p = 0.021) Discussion Stress shielding does occur at higher rates than anticipated following stemless total shoulder arthroplasty, but was not associated with implant migration or failure at 2 years follow-up. Level of evidence IV, Case series.


2018 ◽  
Vol 2 ◽  
pp. 247154921877844
Author(s):  
Stephen P Maier ◽  
Cesar D Lopez ◽  
Zachary J Bloom ◽  
Brian B Shiu ◽  
Djuro Petkovic ◽  
...  

Introduction Lesser tuberosity osteotomy (LTO) is an attractive option for subscapularis management during anatomic shoulder arthroplasty due to the biomechanical strength and reliable bone-to-bone healing. Patients with humeral head avascular necrosis (AVN) may have compromised bone healing, and the outcomes of LTO during AVN are unknown. Methods A retrospective consecutive case series of 6 patients with Cruess grade 4 or 5 humeral head AVN who underwent anatomic shoulder arthroplasty with LTO from 2010 to 2016 was performed. Postoperative radiographic evaluation for LTO healing at 6 months was analyzed, and clinical outcomes at latest follow-up, including range of motion (ROM), strength, and pain were studied.> Results Average age was 50.3 years. AVN was secondary to sickle cell in 1 patient, steroid use for systemic lupus erythematosus in 4, and chronic alcoholism in 1. By 6 months after arthroplasty, 100% had radiographically united and healed LTO. Patients averaged 140 ± 21° of active forward elevation and 42 ± 7° of active external rotation. Patients reported an improvement in visual analogue scale pain from 8.3 preoperatively to 3.8 postoperatively. All patients had a normal abdominal compression test. No patients required revision surgery. Conclusion The use of LTO during anatomic shoulder arthroplasty for AVN has an excellent bony healing rate with improvements in pain, ROM, and strength. The diseases that cause humeral head AVN do not negatively influence LTO healing outcomes during anatomic shoulder replacement. Level of Evidence IV Case Series


2016 ◽  
Vol 25 (7) ◽  
pp. 1163-1169 ◽  
Author(s):  
Danielle J. Casagrande ◽  
Di L. Parks ◽  
Travis Torngren ◽  
Mark A. Schrumpf ◽  
Samuel M. Harmsen ◽  
...  

Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


2021 ◽  
Vol 9 (7) ◽  
pp. 232596712110210
Author(s):  
Sercan Yalcin ◽  
Michael Scarcella ◽  
Joshua Everhart ◽  
Linsen Samuel ◽  
Anthony Miniaci

Background: Weight lifting after total shoulder arthroplasty (TSA) can place significant stresses on implants that could lead to instability, loosening, and increased wear. A TSA system with nonspherical humeral head resurfacing and inlay glenoid—which improves the biomechanics and thus reduces instability, wear, and potential loosening—may be able to tolerate repetitive loads from weight lifting. Purpose: To determine clinical and radiographic outcomes after TSA in weight lifters. Study Design: Case series; Level of evidence, 4. Methods: We prospectively enrolled 16 weight lifters (mean ± SD age, 57.2 ± 7.8 years; 15 male) undergoing primary anatomic TSA (n = 17 shoulders, 1 staged bilateral) with nonspherical humeral head resurfacing and inlay glenoid replacement for glenohumeral osteoarthritis between February 2015 and February 2019. Exclusion criteria were rotator cuff deficiency, revision TSA, post-traumatic arthritis, and inflammatory arthritis. Outcome measures included the rate of return to weight lifting, results of patient-reported outcome measures (Penn Shoulder Score, Kerlan-Jobe Orthopaedic Clinic, and 12-Item Veterans RAND Health Survey), radiographic outcomes, and complication rate. Results: Follow-up was obtained on all patients at a mean of 38 months (range, 14-63 months). All patients returned to competitive weight lifting at 15.6 ± 6.9 weeks. Compared to the preoperative weight lifting level, at last follow-up patients reported performance at the following level: lighter weight, 1 (6%); same weight, 8 (50%); heavier weight, 7 (44%). Preoperative eccentric posterior glenoid wear was common (71% Walch B2 classification; 12/17), but posterior humeral subluxation improved at follow-up according to the Walch index (mean, 55.5% preoperative vs 48.5% postoperative; P < .001) and contact point ratio (mean, 63.9% preoperative vs 50.1% postoperative; P < .001). Pre- to postoperative improvements were seen in Penn Shoulder Score (44.3 vs 82.6; P < .001), Kerlan-Jobe Orthopaedic Clinic (50.6 vs 91.1; P < .001), and 12-Item Veterans RAND Health Survey physical component score but not mental component score. No signs of radiographic loosening were detected in follow-up images, nor were there any postoperative instability episodes or revision surgeries. Conclusion: There were substantial improvements in shoulder function and a high rate of return to weight lifting after TSA with a nonspherical humeral head resurfacing and inlay glenoid component. Radiographically, the humeral head centralized on the glenoid after surgery, and there was no evidence of component loosening at a mean 38-month follow-up.


2021 ◽  
Vol 1 (3) ◽  
pp. 263502542199712
Author(s):  
Jordan D. Walters ◽  
Stephen F. Brockmeier

Background: This technique video reviews anatomic total shoulder arthroplasty (TSA) with a stemless humeral component using a representative case example. Indications: Stemless TSA is indicated for patients with symptomatic glenohumeral arthritis typically younger than 65 years of age. Stemless TSA may be used for other glenohumeral degenerative conditions such as avascular necrosis or posttraumatic arthropathy, provided acceptable humeral bone quality is confirmed intraoperatively using a thumb-press test. Poor bone quality is the primary contraindication. Technique Description: Preoperatively, computed tomography is typically used for planning, and intraoperative navigation through magnetic resonance imaging is also useful. The procedure’s critical elements include beach chair positioning, standard deltopectoral approach with lesser tuberosity osteotomy (LTO), freehand proximal humeral osteotomy, perpendicular proximal humeral exposure and subsequent preparation over a central guidewire, stemless implant and humeral head sizing, perpendicular glenoid exposure and implant placement, and final humeral implantation with LTO repair/fixation. A phased rehabilitation protocol includes 6-week sling immobilization to protect the subscapularis/LTO repair and return to normal activities between 3 and 6 months postoperatively. Discussion/Conclusion: Stemless TSA shows promising early and mid-term outcomes with complication rates, including humeral loosening rates, similar to standard stemmed components. Potential complications include neurovascular injury, infection, glenoid or humeral component loosening, and rotator cuff failure.


2018 ◽  
Vol 100-B (6) ◽  
pp. 761-766 ◽  
Author(s):  
M. Holschen ◽  
M-K. Siemes ◽  
K-A. Witt ◽  
J. Steinbeck

Aims The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA. Material and Methods A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs. Results At final follow-up, the mean ASES was 59 (25 to 97) and the mean adjusted Constant Score was 63% (23% to 109%). Both improved significantly (p < 0.001). The mean forward flexion was 104° (50° to 155°) and mean abduction was 98° (60° to 140°). Nine patients (32%) had a complication; two had an infection and instability, respectively; three had a scapular fracture; and one patient each had delayed wound healing and symptomatic loosening. If implants could be converted to a rTSA without removal of the stem, the operating time was shorter (82 minutes versus 102 minutes; p = 0.018). Conclusion After failure of a HA in the treatment of a proximal humeral fracture, conversion to a rTSA may achieve pain relief and improved shoulder function. The complication rate is considerable. Cite this article: Bone Joint J 2018;100-B:761–6.


2011 ◽  
Vol 21 (6) ◽  
pp. 754-759 ◽  
Author(s):  
Vasileios Petousis ◽  
Lothar Krause ◽  
Gregor Willerding ◽  
Michael H. Foerster ◽  
Nikolaos E. Bechrakis

Purpose. The black iris-lens diaphragm (ILD) can be used in the treatment of traumatic aniridia and aphakia. The aim of our study was to show postoperative functional and anatomic results and complications in a small case series. Methods. We retrospectively analyzed the files of 16 patients managed with a black ILD or a sole iris diaphragm in the period 1994–2007. Four of them were female and 12 were male. The mean age of the group was 50±17 years. At the time of the implantation, all of the eyes had already undergone primary surgical repair. Results. The preoperative best-corrected visual acuity in half of the patients was ≥0.1 and remained stable after the first postoperative year. During the follow-up years, one eye developed a subluxation of the implant and one eye an anterior chamber hemorrhage. At the same time, out of 8 eyes carrying a silicone tamponade in the vitreous cavity, silicone oil entered the anterior chamber in 3 cases. In one case, enucleation was undertaken due to phthisis. Conclusions. In the case of severely traumatized eyes with aniridia and aphakia, the implantation of a black ILD can have a positive effect on functional and anatomic stabilization.


2021 ◽  
Vol 24 (3) ◽  
pp. 125-134
Author(s):  
Kirtan Tankshali ◽  
Dong-Whan Suh ◽  
Jong-Hun Ji ◽  
Chang-Yeon Kim

Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up.Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with a minimum of 2 years of follow-up were enrolled. We evaluated the preoperative and postoperative clinical outcomes, radiological outcomes (notching and loosening), and complications of BIO-RSA at the last follow-up. In addition, we divided these patients into notching and not-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients between the two groups.Results: Visual analog scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles, and Simple Shoulder Test scores improved significantly from preoperative (average: 5, 39.43, 16.22, 3.94) to postoperative (average: 1.71, 78.91, 28.34, 7.8; p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20/38 patients (53%). In the comparison between notching and not-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications were three metaphyseal fractures and one inferior screw malposition. Postoperative complications included one heterotopic ossification, one scapula neck stress fracture, one humeral stem loosening, and one late infection.Conclusions: BIO-RSA resulted in improved clinical outcomes at mid-term follow-up in the Asian population. Although better cosmesis and advantages of glenoid lateralization were observed, we observed higher rates of scapular notching compared to previously reported rates in BIO-RSA studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.


Sign in / Sign up

Export Citation Format

Share Document