scholarly journals Comparison of Interstitial Fluid Glucose Levels Obtained by Continuous Glucose Monitoring and Flash Glucose Monitoring in Patients With Type 2 Diabetes Mellitus Undergoing Hemodialysis

2019 ◽  
Vol 14 (6) ◽  
pp. 1088-1094 ◽  
Author(s):  
Takahiro Yajima ◽  
Hiroshi Takahashi ◽  
Keigo Yasuda

Background: The accuracy of flash glucose monitoring (FGM, FreeStyle Libre Pro [FSL-Pro]) remains unclear in patients with type 2 diabetes mellitus (T2DM) undergoing hemodialysis. Methods: We assessed 13 patients with T2DM undergoing hemodialysis. They simultaneously underwent FGM, continuous glucose monitoring (CGM, iPro2), and self-monitoring blood glucose (SMBG). Results: Parkes error grid analysis against SMBG showed that 49.0% and 51.0% of interstitial fluid glucose (ISFG) levels measured using FGM and 93.3% and 6.7% of those measured using CGM fell into zones A and B, respectively. Mean absolute relative difference (MARD) against SMBG for FGM was significantly higher than that for CGM (19.5% ± 13.2% vs 8.1% ± 7.6%, P < .0001). Parkes error grid analysis of 2496 paired ISFG levels between FGM and CGM showed that 53.6%, 46.2%, and 0.2% of the plots fell into zones A, B, and C, respectively. Mean ISFG levels were lower with FGM than with CGM (143.7 ± 67.2 mg/dL vs 164.6 ± 58.5 mg/dL; P < .0001). Mean absolute relative difference of ISFG levels between FGM and CGM was 19.2% ± 13.8%. Among three groups classified according to CGM ISFG levels (hypoglycemia, <70 mg/dL; euglycemia, 70-180 mg/dL; and hyperglycemia, >180 mg/dL), the MARDs for hypoglycemia (31.9% ± 25.0%) and euglycemia (22.8% ± 14.6%) were significantly higher than MARD for hyperglycemia (13.0% ± 8.5%) ( P < .0001 in both). Conclusions: Flash glucose monitoring may be clinically acceptable. Average ISFG levels were lower with FGM than with CGM, and MARDs were higher for hypoglycemia and euglycemia in patients with T2DM undergoing hemodialysis.

2020 ◽  
Vol 2020 ◽  
pp. 1-6 ◽  
Author(s):  
Rengna Yan ◽  
Huiqin Li ◽  
Xiaocen Kong ◽  
Xiaofang Zhai ◽  
Maoyuan Chen ◽  
...  

Background. The purpose of this study was to investigate the accuracy of the continuously stored data from the Abbott FreeStyle Libre flash glucose monitoring (FGM) system in Chinese diabetes patients during standard meal tests when glucose concentrations were rapidly changing. Subjects and Methods. Interstitial glucose levels were monitored for 14 days in 26 insulin-treated patients with type 2 diabetes using the FGM system. Standard meal tests were conducted to induce large glucose swings. Venous blood glucose (VBG) was tested at 0, 30, 60, and 120 min after standard meal tests in one middle day of the first and second weeks, respectively. The corresponding sensor glucose values were obtained from interpolating continuously stored data points. Assessment of accuracy was according to recent consensus recommendations with median absolute relative difference (MARD) and Clarke and Parkes error grid analysis (CEG and PEG). Results. Among 208 paired sensor-reference values, 100% were falling within zones A and B of the Clarke and Parkes error grid analysis. The overall MARD was 10.7% (SD, 7.8%). Weighted least squares regression analysis resulted in high agreement between the FGM sensor glucose and VBG readings. The overall MTT results showed that FGM was lower than actual VBG, with MAD of 22.1 mg/dL (1.2 mmol/L). At VBG rates of change of -1 to 0, 0 to 1, 1 to 2, and 2 to 3 mg/dl/min, MARD results were 11.4% (SD, 8.7%), 9.4% (SD, 6.5%), 9.9% (SD, 7.5%), and 9.5% (SD, 7.7%). At rapidly changing VBG concentrations (>3 mg/dl/min), MARD increased to 19.0%, which was significantly higher than slow changing BG groups. Conclusions. Continuously stored interstitial glucose measurements with the FGM system were found to be acceptable to evaluate VBG in terms of clinical decision during standard meal tests. The continuously stored data from the FGM system appeared to underestimate venous glucose and performed less well during rapid glucose changes.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Satoshi Ida ◽  
Ryutaro Kaneko ◽  
Kanako Imataka ◽  
Kaoru Okubo ◽  
Yoshitaka Shirakura ◽  
...  

The aim of this study was to evaluate the effects of flash glucose monitoring on dietary variety, physical activity, and self-care behavior in patients with diabetes. This study included outpatients with diabetes using insulin who presented at the Department of Diabetes and Metabolism of the Ise Red Cross Hospital. Before initiating flash glucose monitoring and 12 weeks after its initiation, blood glucose-related parameters were assessed and self-administered questionnaires were completed (Dietary Variety Score (DVS), the International Physical Activity Questionnaire (IPAQ), the Summary of Diabetes Self-Care Activities Measure (SDSCA), and the Diabetes Treatment Satisfaction Questionnaire (DTSQ)) and compared between the two time points. We analyzed 42 patients with type 1 diabetes mellitus and 48 patients with type 2 diabetes mellitus. In patients with type 2 diabetes mellitus, but not type 1 diabetes mellitus, there was an increase in moderate/high category scores for IPAQ (P<0.001) and for treatment satisfaction reported via DTSQ. Furthermore, in patients with type 2 diabetes mellitus, the glycemic excursion index improved significantly and HbA1c decreased significantly (from 7.7 (1.2) to 7.4 (0.8), P=0.025). Results showed that standard deviation and mean amplitude of glycemic excursions significantly decreased in patients with type 1 diabetes mellitus (from 71.2 (20.4) to 66.2 (17.5), P=0.033 and from 124.6 (31.9) to 108.1 (28.4), P<0.001, respectively). Flash glucose monitoring is a useful tool to improve physical activity in patients with type 2 diabetes.


2018 ◽  
Vol 14 (2) ◽  
pp. 86 ◽  
Author(s):  
Richard Hellmund ◽  
Raimund Weitgasser ◽  
Deirdre Blissett

Aims:Estimate the costs associated with flash glucose monitoring as a replacement for routine self-monitoring of blood glucose (SMBG) in patients with type 2 diabetes mellitus (T2DM) using intensive insulin, from a UK National Health Service (NHS) perspective.Methods:The base-case cost calculation used the frequency of SMBG and healthcare resource use observed in the REPLACE trial. Scenario analyses considered SMBG at the flash monitoring frequencies observed in the REPLACE trial (8.3 tests per day) and a real-world analysis (16 tests per day).Results:Compared with 3 SMBG tests per day, flash monitoring would cost an additional £585 per patient per year, offset by a £776 reduction in healthcare resource use, based on reductions in emergency room visits (41%), ambulance call-outs (66%) and hospital admissions (77%) observed in the REPLACE trial. Per patient, the estimated total annual cost for flash monitoring was £191 (13.4%) lower than for SMBG. In the scenarios based on acquisition cost alone, flash monitoring was cost-neutral versus 8.3 SMBG tests per day (5% decrease) and cost-saving at higher testing frequencies.Conclusion:From a UK NHS perspective, for patients with T2DM using intensive insulin, flash monitoring is potentially cost-saving compared with routine SMBG irrespective of testing frequency. Keywords


Author(s):  
Maoyuan Chen ◽  
Huiqin Li ◽  
Yun Shen ◽  
Bingli Liu ◽  
Renna Yan ◽  
...  

Abstract Objective To investigate the effects of Flash Glucose Monitoring (FGM) on glucose profile in people with Type 2 Diabetes Mellitus (T2DM) receiving anti-diabetic drug medication. Methods This is a prospective non-randomized uncontrolled study. 111 people with T2DM were enrolled and received FGM for 14 days. There was no change of anti-diabetic medication during the 14 days. The plasma glucose concentration on day 2 was used as baseline and the day 13 was considered as study end point. The parameters to compare were mean plasma glucose (MPG), glucose variations, and incidence of hypoglycemia during the FGM period. The multivariate linear stepwise regression analysis was applied to determine the independent factors that affect MPG difference. Results This study analyzed the data of a total of 111 people with T2DM (male 60 and female 51). The general clinical data of these patients were as follows: age: 65.0±6.7 years old; duration of diabetes: 11.6±6.8 years; HbA1c: 61.2±13.3 mmol/mol; body mass index (BMI): 25.2±3.2 kg/m². Using FGM, people with T2DM were able to change daily diet and exercise through which significant reductions in MPG on days 12 or 13 were achieved as compared with that of day 2 (P=0.04 or P=0.003, respectively). The glucose variations, such as standard deviation (SD) of plasma glucose, coefficient of variation (CV), and mean amplitude of glycemic excursion (MAGE), progressively declined starting from day 6 as compared with baseline (P=0.016, P=0.003, or P=0.012, respectively). The incremental area over the curve (AOC) of the hypoglycemia (<3.9 mmol/L) had a significant reduction starting from the day 3 (P=0.001). When people with T2DM were divided into 3 groups based on the tertile of HbA1c (high, middle, and low concentrations), the reduction of MPG in patients with high concentration of HbA1c were much larger than that in middle and low concentration group patients (P=0.001 for both). The incidence of hypoglycemia was improved in the low concentration group (P=0.017). The optimal frequency of scanning time required to maintain euglycemia was 11.7 times/day as calculated by the receiver operating characteristic (ROC) analysis. Conclusion Using FGM to monitor glucose concentration at 11.7 times/day, people with T2DM can achieve a better glucose control in addition to anti-diabetic drug medication through changing daily diet and exercise, especially in patients with high concentration of HbA1c (>66.1 mmol/mol).


Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 973-P
Author(s):  
ALLISON LAROCHE ◽  
KRISTINA UTZSCHNEIDER ◽  
CATHERINE PIHOKER