An Attachment Including a +20-D Lens to Gain Extended Field Images in Wide-Angle Optical Coherence Tomography Angiography

2019 ◽  
Vol 4 (3) ◽  
pp. 210-213
Author(s):  
Osamu Sawada ◽  
Takamasa Mori ◽  
Yusuke Ichiyama ◽  
Shumpei Obata ◽  
Masashi Kakinoki ◽  
...  

Purpose: This article evaluates the clinical usefulness of an attachment involving a +20-D lens to gain extended field images on wide-angle optical coherence tomography angiography (OCTA). Methods: An attachment with a +20-D lens was developed to take OCTA images of anterior segments, and it was used to obtain extended field images of the posterior segment in this study. Ten eyes of 5 individuals who did not have a history of ocular or systemic disease underwent wide-angle OCTA with a 12 × 12-mm center field using the PLEX Elite 9000 with and without the attachment. The ratio of the area of the center field to the area of the extended field with the attachment was calculated. Results: The mean area of the center image was 125 disc areas and that of the field extended by the attachment was 210 disc areas. The mean ratio between the center field and the extended field was 1.67. Conclusions: The attachment involving the +20-D lens seems to be clinically useful to gain extended field images on wide-angle OCTA.

2021 ◽  
Author(s):  
Yadollah Eslami ◽  
Sepideh Ghods ◽  
Massood Mohammadi ◽  
Mona Safizadeh ◽  
Ghasem Fakhraie ◽  
...  

Abstract Purpose: To evaluate the relationship between structure and function in moderate and advanced primary open-angle glaucoma (POAG) and to determine the accuracy of structure and vasculature for discriminating moderate from advanced POAG.Methods: In this cross-sectional study 25 eyes with moderate and 40 eyes with advanced POAG were enrolled. All eyes underwent measurement of the thickness of circumpapillary retinal nerve fiber layer (cpRNFL) and macular ganglion cell complex (GCC), and optical coherence tomography angiography (OCTA) of the optic nerve head (ONH) and macula. Visual field (VF) was evaluated by Swedish interactive threshold algorithm and 24-2 and 10-2 patterns. The correlation between structure and vasculature and the mean deviation (MD) of the VFs was evaluated by a partial correlation coefficient. The area under the receiver operating characteristic curve (AUC) was applied for assessing the power of variables for discrimination moderate from advanced POAG.Results: Superior cpRNFL, superior GCC, whole image vessel density (wiVD) of the ONH area, and vessel density in inferior quadrant of perifovea had the strongest correlation with the mean deviation (MD) of the VF 24-2 (r= .351, .558, .649 and .397; p< .05). The greatest AUCs belonged to inferior cpRNFL (.789), superior GCC (.818), vessel density of the inferior hemifield of ONH area (.886), and vessel density in inferior quadrant of perifovea (.833) without statistically significant difference in pairwise comparison.Conclusion: Vasculature has a stronger correlation than the structure with MD in moderate and advanced POAG and is as accurate as structure in discrimination moderate from advanced POAG.


2019 ◽  
Vol 3 (5) ◽  
pp. 283-288 ◽  
Author(s):  
Chirag Shah ◽  
Rami Gabriel ◽  
Sanjay Kedhar ◽  
Baruch Kuppermann ◽  
Mitul Mehta

Purpose: This article identifies subclinical microvascular changes in systemic lupus erythematosus (SLE) patients using vascular perfusion densities derived from optical coherence tomography angiography (OCTA). Methods: A retrospective review was performed on individuals with SLE (10 eyes of 5 patients) and age-matched controls imaged with a spectral-domain OCT system (XR Avanti, Optovue, Inc). A split-spectrum amplitude-decorrelation algorithm (SSADA) generated OCTA of the superficial retinal capillaries, deep retinal capillaries, and foveal avascular zone (FAZ). Skeletonized OCTAs were used to create capillary vessel density (VD) values for each image. VD values were compared with clinical staging, and groups were compared using Kruskal–Wallis and Mann–Whitney tests. Results: Both the superficial (SCP) and deep capillary plexus (DCP) had a statistically significant decrease in VD in the SLE group when compared with the control group ( P < .05). The average VD ± SD for normal individuals in the 3 mm × 3 mm scans was 26.11 ± 1.2 and 37.45 ± 1.8 for the SCP and DCP, respectively. For SLE patients the mean ± SD was 18.46 ± 0.84 and 30.22 ± 1.5 for SCP and DCP, respectively. The mean FAZ was found to be 0.207 mm ± 0.02 for healthy controls and 0.350 mm ± 0.02 for SLE patients ( P < .001). Conclusions: In this paper we demonstrate a significantly enlarged FAZ and decreased VD in a small sample of patients with lupus. The SCP VD demonstrated a dose-response–type negative relationship with increased systemic lupus severity. Larger-sample, prospective studies may allow us to further characterize subclinical SLE pathology with OCTA, and OCTA may further provide a means for monitoring the severity or progression of other microvascular diseases.


2019 ◽  
Vol 3 (4) ◽  
pp. 260-262
Author(s):  
Pimpiroon Ploysangam ◽  
Faruk Koreishi ◽  
Gareth M.C. Lema

Purpose: To report a case of ophthalmic artery occlusion after injection of heroin into the forehead. Methods: Retrospective case report. Results: A 27-year-old patient with a history of intravenous heroin abuse presented with a left ophthalmic artery occlusion after attempting to inject heroin into a vein in her forehead. Exam was significant for diffuse retinal edema, disc edema, disc hemorrhage, and diffuse retinal hemorrhages. Findings were also noted in the widefield image, optical coherence tomography, and optical coherence tomography angiography of the retina. Conclusions: This patient suffered from a severe form of talc retinopathy resulting in an ophthalmic artery occlusion after injecting heroin into her forehead. To our knowledge, this is the first instance of combined ophthalmic artery occlusion and talc retinopathy resulting from intentional injection into a superficial facial vein.


2019 ◽  
Vol 103 (11) ◽  
pp. 1677-1684 ◽  
Author(s):  
Ana I M Miguel ◽  
André B Silva ◽  
Luis F Azevedo

BackgroundCompared with current imaging methods, the diagnostic performance and the advantages and limitations of optical coherence tomography angiography (OCTA) remain unclear. We performed a systematic review and meta-analysis of studies investigating vessel density (VD) in patients with glaucoma using OCTA.MethodsWe conducted a literature search on PubMed, Scopus, Web of Science, ISI Conference Proceedings and Google Scholar, along with a manual search, from January 2006 to March 2018. We included prospective studies that used OCTA to compare the VD in glaucomatous eyes with healthy control eyes.ResultsOf 3045 screened articles, 24 were included in a broad characterisation and 18 in the meta-analysis. We observed a statistically significant reduction in the mean peripapillary VD (MPVD) in glaucoma (MPVD: 57.53%, 95% CI 52.60 to 62.46, p< 0.001) compared with controls (MPVD: 65.47%, 95% CI 59.82 to 71.11; standardised mean difference [SMD], –1.41, 95% CI –1.62 to –1.20, p< 0.001) for 888 glaucomatous and 475 healthy eyes, and also in the mean-whole optic nerve image VD (SMD, –9.63, 95% CI –10.22 to –9.03, p<0.001), mean inside-disc VD (SMD, − 9.51, 95% CI –12.66 to –6.36, p<0.05) and mean parafoveal VD (SMD, –3.92, 95% CI –4.73 to –3.12, p<0.001). Subgroup analyses revealed a significant difference in the MPVD across glaucoma subtypes and OCTA devices.ConclusionThis suggests the diagnostic utility of OCTA in detecting glaucomatous eyes; however, further longitudinal prospective studies are welcomed to characterise vascular changes in glaucoma.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243830
Author(s):  
Yining Dai ◽  
Hao Zhou ◽  
Qinqin Zhang ◽  
Zhongdi Chu ◽  
Lisa C. Olmos de Koo ◽  
...  

Purpose To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). Methods Diabetic subjects with different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans. Results Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8μm2 vs 1574.4±255.0 μm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively). Conclusions CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.


2021 ◽  
Vol 8 ◽  
Author(s):  
Min Fu ◽  
Pan Hu ◽  
Gang Zhang ◽  
Ludonghan Huang ◽  
Huan Xu ◽  
...  

Significance: Perifoveal exudative vascular anomalous complex (PEVAC) is a unique clinical lesion. It manifests as isolated lesions and is easily misdiagnosed. Thus far, few PEVAC case reports have been published. PEVAC is typically inconsistent with other reported macular lesions.Purpose: To report our 24-month follow-up experience on the treatment of PEVAC with a micropulse laser (MPL).Case Report: A 56-year-old Chinese woman with no history of other diseases complained of decreased vision in her left eye that had persisted for more than 1 year. Comprehensive ophthalmic examinations were performed, including a vision test, slit lamp fundus exam, optical coherence tomography (OCT), optical coherence tomography angiography (OCT-A), fluorescein fundus angiography (FFA) and indocyanine green angiography (ICGA). Intravitreal injection of ranibizumab was ineffective, and bleeding, exudation and visual acuity were not improved. After two rounds of micropulse laser (MPL) treatment, the patient was followed up, and the prognosis was good.Conclusion: PEVAC is very rare, and early diagnosis is important, as the lesions readily cause irreversible damage. Our results indicate that an MPL can be used as an alternative treatment for PEVAC patients.


Author(s):  
Pasha Anvari ◽  
Amin Najafi ◽  
Reza Mirshahi ◽  
Mahsa Sardarinia ◽  
Maryam Ashrafkhorasani ◽  
...  

Purpose: To compare the area of the foveal avascular zone (FAZ) in the superficial and deep retinal layers using two different spectral-domain optical coherence tomography angiography (OCTA) devices. Methods: A cross-sectional comparative study was conducted to obtain macular OCTA images from healthy subjects using Optovue RTVue XR Avanti (Optovue, Inc, Fremont, CA) and Spectralis HRA+OCTA (Heidelberg Engineering, Heidelberg, Germany). Two independent trained graders measured the FAZ area using automated slab segmentation. The FAZ area in the superficial and deep retinal layers were compared. Results: Twenty-three eyes of 23 subjects were included. The graders agreement was excellent (>0.86) for all measurements. The mean FAZ area was significantly larger at the superficial retinal layer as compared to the deep retinal layer on both devices (0.31 ± 0.08 mm2 vs 0.26 ± 0.08 mm2 in Optovue and 0.55 ± 0.16 mm2 vs 0.36 ± 0.13 mm2 in Spectralis, both P < 0.001). The mean FAZ area was significantly greater in the superficial and deep retinal layers using Spectralis as compared to Optovue measurements (P < 0.001 for both comparisons). Conclusion: In contrast to previous reports, the FAZ area was larger in the superficial retina as compared to deep retinal layers using updated software versions. Measurements from different devices cannot be used interchangeably.


2018 ◽  
Vol 103 (10) ◽  
pp. 1373-1379 ◽  
Author(s):  
Norihiro Suzuki ◽  
Yoshio Hirano ◽  
Taneto Tomiyasu ◽  
Ryo Kurobe ◽  
Yusuke Yasuda ◽  
...  

AimsTo detect collateral vessels using optical coherence tomography angiography (OCTA) in eyes with branch retinal vein occlusion (BRVO) and to investigate the associations with visual outcomes and macular oedema.MethodsEyes with macular oedema secondary to BRVO that underwent OCTA at baseline and were followed up for more than 6 months were enrolled. The presence of collaterals, whether the collaterals were leaky or not, and the associations with visual outcomes and macular oedema were investigated.ResultsTwenty-eight eyes of 28 patients (8 men and 20 women; mean age, 68 years) were enrolled. Collaterals were detected in 23 eyes (82%) and already existed at the initial visit. Collaterals were more frequently detected in eyes with major BRVO or ischaemic type. One-third of the collaterals were leaky and all of the leaky collaterals had microaneurysms (MAs) inside. Macular oedema in eyes with collaterals was more quickly and frequently resolved than that in eyes without collaterals, but there were no significant differences. Collateral vessel formation did not seem to impact on visual outcomes, but the mean baseline central retinal thickness (CRT) was significantly higher in eyes with collaterals, and the mean CRT reduction at 6 months after treatments was significantly greater than in eyes without collaterals.ConclusionsThese results suggest that collateral vessels are formed at the acute phase in eyes with BRVO. In addition, the presence of collaterals might be associated with absorption of macular oedema, but MAs formed in collaterals sometimes can cause macular oedema.


Sign in / Sign up

Export Citation Format

Share Document