scholarly journals Quantitative assessment of choriocapillaris flow deficits in diabetic retinopathy: A swept-source optical coherence tomography angiography study

PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243830
Author(s):  
Yining Dai ◽  
Hao Zhou ◽  
Qinqin Zhang ◽  
Zhongdi Chu ◽  
Lisa C. Olmos de Koo ◽  
...  

Purpose To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). Methods Diabetic subjects with different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans. Results Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8μm2 vs 1574.4±255.0 μm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively). Conclusions CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.

2019 ◽  
Vol 236 (04) ◽  
pp. 551-554 ◽  
Author(s):  
Stefan Trachsler ◽  
Arthur Baston ◽  
Marcel Menke

Abstract Purpose To compare 4 optical coherence tomography-angiography (OCT-A) devices for foveal avascular zone (FAZ) measurements in healthy subjects. Methods The central retinas of 24 eyes of 12 healthy subjects were scanned with 4 different OCT-A devices (Optovue RTVue-XR, Zeiss Cirrus 5000-HD-OCT, a prototype Spectralis OCT2, Heidelberg Engineering, and Topcon DRI-OCT Triton Swept-source OCT). For the Topcon, Zeiss, and Optovue devices, 3-mm and 6-mm scans were performed. The Heidelberg device only provided 4-mm scans. En-face OCT-A images of the superficial and deep capillary plexus of the macular area were generated. The FAZ areas were measured and compared. Results Twenty-four healthy eyes were included. OCT-A devices showed significant differences in FAZ measurements. The Zeiss OCT-A device measured the smallest values for foveal avascular area (mean 218.7 mm2), followed by the Optovue device (229.6 mm2), the Topcon device (239.3 mm2), and the Heidelberg device (250.4 mm2). Differences were statistically significant for following devices: Heidelberg versus Optovue (p < 0.001), Heidelberg versus Zeiss (p < 0.001), Topcon versus Zeiss (p < 0.001), and Optovue versus Zeiss (p = 0.046). For the Optovue device, FAZ measurements were significantly different between 3 mm (mean 220 mm2) and 6 mm (mean 239.3 mm2, p = 0.007) scans. All other devices showed no significant difference within scan modes. Conclusion Current OCT-A devices provide images that allow such measurements, but values showed significant differences between devices and, for the Optovue instrument, even within scan modes. The data for OCTA measurements cannot be transferred interchangeably between the devices. Therefore, a patient should always be measured with the same device.


PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0259880
Author(s):  
Ai Ichioka ◽  
Sotaro Ooto ◽  
Akihito Uji ◽  
Saki Manabe ◽  
Chieko Shiragami ◽  
...  

Purpose To analyze the structure of the choriocapillaris in healthy eyes by using averaged en face images acquired using swept source optical coherence tomography angiography and to examine the changes in the macular profile in relation to age, sex, axial length, and choroidal thickness. Methods This prospective, cross-sectional study included 81 eyes of 81 subjects without ophthalmologic or systemic diseases who underwent a full ophthalmologic examination, including 3 × 3-mm macular optical coherence tomography angiography. Four to nine choriocapillaris en face images were registered and averaged. The averaged images were then binarized and analyzed. Results The averaged choriocapillaris images showed a continuous capillary meshwork, whereas the unaveraged images had a granular appearance. The mean total area and size of flow voids were 0.99 ± 0.20 mm2 and 567.8 ± 201.5 μm2, respectively, and these values correlated positively with age (p = 0.002, R = 0.336 and p = 0.026, R = 0.247, respectively). Age-related gains in the mean total area and flow void size were 4.20 × 10−3 mm2 and 3.07 μm2 per year, respectively. However, the mean total area and flow void size had no significant correlation with axial length, subfoveal choroidal thickness, or sex. Conclusions Multiple averaged en face swept source optical coherence tomography angiography is more effective than a single optical coherence tomography angiography scan for better visualizing the choriocapillaris. The total area and size of flow voids within a 3 × 3-mm macular area positively correlated with age. This technique can be useful for investigating the changes arising in macular diseases.


2018 ◽  
Vol 103 (3) ◽  
pp. 415-420 ◽  
Author(s):  
Danqi Fang ◽  
Fang Yao Tang ◽  
Haifan Huang ◽  
Carol Y Cheung ◽  
Haoyu Chen

PurposeTo investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects.MethodsThirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson’s correlation coefficient (r), ICC and Bland-Altman plot.ResultsThe repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from −0.0763 to 0.0954 mm2 for FAZ area and from −0.0491 to 0.1136 for parafoveal vessel density.ConclusionsThe macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects.


Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Reza Mirshahi ◽  
Pasha Anvari ◽  
Hamid Riazi-Esfahani ◽  
Mahsa Sardarinia ◽  
Masood Naseripour ◽  
...  

AbstractThe purpose of this study was to introduce a new deep learning (DL) model for segmentation of the fovea avascular zone (FAZ) in en face optical coherence tomography angiography (OCTA) and compare the results with those of the device’s built-in software and manual measurements in healthy subjects and diabetic patients. In this retrospective study, FAZ borders were delineated in the inner retinal slab of 3 × 3 enface OCTA images of 131 eyes of 88 diabetic patients and 32 eyes of 18 healthy subjects. To train a deep convolutional neural network (CNN) model, 126 enface OCTA images (104 eyes with diabetic retinopathy and 22 normal eyes) were used as training/validation dataset. Then, the accuracy of the model was evaluated using a dataset consisting of OCTA images of 10 normal eyes and 27 eyes with diabetic retinopathy. The CNN model was based on Detectron2, an open-source modular object detection library. In addition, automated FAZ measurements were conducted using the device’s built-in commercial software, and manual FAZ delineation was performed using ImageJ software. Bland–Altman analysis was used to show 95% limit of agreement (95% LoA) between different methods. The mean dice similarity coefficient of the DL model was 0.94 ± 0.04 in the testing dataset. There was excellent agreement between automated, DL model and manual measurements of FAZ in healthy subjects (95% LoA of − 0.005 to 0.026 mm2 between automated and manual measurement and 0.000 to 0.009 mm2 between DL and manual FAZ area). In diabetic eyes, the agreement between DL and manual measurements was excellent (95% LoA of − 0.063 to 0.095), however, there was a poor agreement between the automated and manual method (95% LoA of − 0.186 to 0.331). The presence of diabetic macular edema and intraretinal cysts at the fovea were associated with erroneous FAZ measurements by the device’s built-in software. In conclusion, the DL model showed an excellent accuracy in detection of FAZ border in enfaces OCTA images of both diabetic patients and healthy subjects. The DL and manual measurements outperformed the automated measurements of the built-in software.


2016 ◽  
Vol 2016 ◽  
pp. 1-3 ◽  
Author(s):  
Marcus Ang ◽  
Yijun Cai ◽  
Anna C. S. Tan

Purpose. To describe a novel technique of adapting a swept-source optical coherence tomography angiography (OCTA) to image corneal vascularization.Methods. In this pilot cross-sectional study, we obtained 3 × 3 mm scans, where 100,000 A-scans are acquired per second with optical axial resolution of 8 μm and lateral resolution of 20 μm. This was performed with manual “XYZ” focus without the anterior segment lens, until the focus of the corneoscleral surface was clearly seen and the vessels of interest were in focus on the corresponding red-free image. En face scans were evaluated based on image quality score and repeatability.Results. We analyzed scans from 10 eyes (10 patients) with corneal vascularization secondary to contact lens use in 4 quadrants, with substantial repeatability of scans in all quadrants (mean image quality score 2.7 ± 0.7;κ=0.75). There was no significant difference in image quality scores comparing quadrants (superior temporal: 2.9 ± 0.6, superior nasal: 2.8 ± 0.4, inferior temporal: 2.5 ± 0.9, and inferior nasal: 2.4 ± 1.0;P=0.276) and able to differentiate deep and superficial corneal vascularization.Conclusion. This early clinical study suggests that the swept-source OCTA used may be useful for examining corneal vascularization, which may have potential for clinical applications such as detecting early limbal stem cell damage.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
A. R. Kee ◽  
V. C. H. Yip ◽  
E. L. T. Tay ◽  
C. W. Lim ◽  
J. Cheng ◽  
...  

Abstract Background To understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability. Methods A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated. Results A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761–1.000) compared to Swept Source (0.113–0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source. Conclusions AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.


Sign in / Sign up

Export Citation Format

Share Document