The detection of high-strength concrete exposed to high temperatures using infrared thermal imaging technique

2015 ◽  
Vol 19 (sup1) ◽  
pp. S1-162-S1-167 ◽  
Author(s):  
H. X. Du ◽  
H. P. Wu ◽  
F. J. Wang ◽  
R. Z. Yan
2008 ◽  
Vol 73 (624) ◽  
pp. 341-347 ◽  
Author(s):  
Masashi MATSUDO ◽  
Hirokazu NISHIDA ◽  
Takahiro OHTSUKA ◽  
Takeo HIRASHIMA ◽  
Takeo ABE

2014 ◽  
Vol 1014 ◽  
pp. 49-52
Author(s):  
Xiao Ping Su

With the wide application of high strength concrete in the building construction,the risk making concrete subject to high temperatures during a fire is increasing. Comparison tests on the mechanical properties of high strength concrete (HSC) and normal strength concrete (NSC) after the action of high temperature were made in this article, which were compared from the following aspects: the peak stress, the peak strain, elasticity modulus, and stress-strain curve after high temperature. Results show that the laws of the mechanical properties of HSC and NSC changing with the temperature are the same. With the increase of heating temperature, the peak stress and elasticity modulus decreases, while the peak strain grows rapidly. HSC shows greater brittleness and worse fire-resistant performance than NSC, and destroys suddenly. The research and evaluation on the fire-resistant performance of HSC should be strengthened during the structural design and construction on the HSC buildings.


2020 ◽  
Vol 26 (1) ◽  
pp. 118-127
Author(s):  
Teuku Budi Aulia ◽  
Muttaqin Muttaqin ◽  
Mochammad Afifuddin ◽  
Zahra Amalia

High-strength concrete is vulnerable to high temperatures due to its high density. The use of polypropylene fibers could prevent structure explosion by forming canals due to melted fibers during fire, thus release its thermal stress. This study aims to determine the effect of polypropylene fibers on compressive strength of high-strength concrete after combustion at 400ºC for five hours. High-strength concrete was made by w/c-ratio 0.3 with cement amount 550 kg/m3 and added with silica fume 8% and superplasticizer 4% by cement weight. The variations of polypropylene fibers were 0%, 0.2% and 0.4% of concrete volume. The compression test was carried out on standard cylinders Ø15/30 cm of combustion and without combustion specimens at 7 and 28 days. The results showed that compressive strength of high-strength concretes without using polypropylene fibers decreased in post-combustion compared with specimens without combustion, i.e., 0.81% at 7 days and 23.42% at 28 days. Conversely, the use of polypropylene fibers can increase post-combustion compressive strength with a maximum value resulted in adding 0.2% which are 25.52% and 10.44% at 7 and 28 days respectively. It can be concluded that the use of polypropylene fibers is effective to prevent reduction of high-strength concrete compressive strength that are burned at high temperatures.


Sign in / Sign up

Export Citation Format

Share Document