scholarly journals A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up

2013 ◽  
Vol 8 (1) ◽  
pp. 20 ◽  
Author(s):  
ShiJun Wang ◽  
ShuDong Zhang ◽  
YuChi Zhao
2021 ◽  
Vol 103-B (7 Supple B) ◽  
pp. 78-83 ◽  
Author(s):  
Gordon G. Roedel ◽  
Beau J. Kildow ◽  
Daniel S. Sveom ◽  
Kevin L. Garvin

Aims Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Methods Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis. Results Clinical outcomes showed significant improvement of mean Harris Hip Scores from 52.8 (SD 13.5) preoperatively to 94.8 (SD 7.6) postoperatively. One hip was revised for recurrent instability, and there were no infections. No hips were revised for mechanical loosening or osteolysis. Mean polyethylene linear wear was 0.04 mm/year and volumetric wear was 6.22 mm3/year, with no significant differences between head size or material. Osteolysis was not present in any of the hips. Conclusion The use of HXLPE in THA for patients aged 50 years and younger has performed exceptionally well without evidence of significant wear causing mechanical loosening or necessitating revision. The radiolucent lines of the acetabular component must be followed to determine the prognostic significance. This investigation represents the longest clinical follow-up of a large, consecutive cohort of patients aged 50 years or younger with THA using HXLPE. This long-term analysis found negligible polyethylene wear, no incidence of aseptic loosening, and excellent clinical outcomes at and beyond 15 years of follow-up. Cite this article: Bone Joint J 2021;103-B(7 Supple B):78–83.


2017 ◽  
Vol 27 (6) ◽  
pp. 532-536 ◽  
Author(s):  
Motoki Sonohata ◽  
Masaru Kitajima ◽  
Shunsuke Kawano ◽  
Masaaki Mawatari

Introduction Total hip arthroplasty (THA) in the young is challenging. The purpose of this study was to retrospectively determine the clinical, radiographic, and polyethylene wear rate of relatively young patients. Methods We evaluated the outcome of consecutive patients receiving primary THA who were under 40 years of age with a minimum 10-year follow-up. Indications for THA in these patients were osteoarthritis due to developmental dysplasia of the hip joint (9 hips), osteonecrosis of the femoral head (7 hips), juvenile idiopathic arthritis (2 hips), and osteoarthritis due to Perthes disease (1 hip). All THA were performed with a cross-linked ultra-high-molecular-weight polyethylene (XLPE) liner against zirconium heads with cementless implants. Results The average Japanese Orthopaedic Association hip score significantly improved from 42 to 93 points at the latest follow-up. The mean steady wear was 0.015 mm/year (maximum 0.033 mm/year), and the mean creep wear was 0.111 mm (maximum 0.4 mm). Osteolysis was observed around 1 acetabular component and 2 stems. 1 femoral component had subsidence over 5 mm. All of the femoral components achieved fixation with an optimal interface with spot welds at the latest follow-up. Stress shielding was observed in all hips. Conclusions THA using an XLPE liner against zirconium heads appeared to have improved THA longevity. However, the imaging findings in some cases were suggestive of wear debris. A rigorous continual follow-up is required for relatively young patients undergoing THA.


2021 ◽  
Vol 103-B (7 Supple B) ◽  
pp. 73-77
Author(s):  
Charles Murray Lawrie ◽  
Robert L. Barrack ◽  
Ryan M. Nunley

Aims Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA. Methods This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m2, and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported. Results A total of 43 patients were enrolled. At minimum follow-up of five years, 23 (53.4%) returned for clinical and radiological review, 25 (58.1%) had metal ion analysis performed, 19 (44.2%) underwent dual energy x-ray absorptiometry scans, and 25 (58%) completed a pain-drawing questionnaire. The mean modified Harris Hip Scores improved significantly from 54.8 (SD 19) preoperatively to 93.08 (SD 10.5) five years postoperatively (p < 0.001). One patient was revised for aseptic acetabular loosening. The mean cobalt levels increased from 0.065 μg/l (SD 0.03) to 0.08 (SD 0.05) and the mean titanium levels increased from 0.35 (SD 0.13) to 0.78 (SD 0.29). The femoral BMD ratio decreased in Gruen Zone 1 (91.9%) at five years postoperatively compared with the baseline scores at six weeks potoperatively. The femoral BMD ratio was maintained in Gruen zones 2 to 7. Conclusion The use of a modular DM component and a cementless, tapered femoral stem shows excellent mid-term survivorship with minimal concerns for corrosion and metal ion release in a cohort of young, active patients undergoing primary THA. Cite this article: Bone Joint J 2021;103-B(7 Supple B):73–77.


2010 ◽  
Vol 81 (5) ◽  
pp. 570-578 ◽  
Author(s):  
Maiken Stilling ◽  
Kristian Larsen ◽  
Niels T Andersen ◽  
Kjeld Søballe ◽  
Søren Kold ◽  
...  

2018 ◽  
Vol 02 (02) ◽  
pp. 092-096
Author(s):  
Muyibat Adelani ◽  
Frank Bohnenkamp ◽  
Gail Pashos ◽  
John Clohisy ◽  
Adam Sassoon

AbstractThe survivorship of contemporary total hip arthroplasty has improved substantially as a result of the success of highly cross-linked polyethylene. Nevertheless, there is limited information on its performance in extremely young patients. The purpose of this study is to evaluate the (1) clinical and radiographic outcomes, (2) polyethylene wear rates, and (3) mid-term survivorship of total hip arthroplasty in patients 21 years or younger using highly cross-linked polyethylene. After Institutional Review Board approval, the authors identified 45 patients aged 21 years or younger (56 hips) who underwent primary total hip arthroplasty with highly cross-linked polyethylene at their institution by the senior author between 2000 and 2009. Patients were followed for a minimum of 2 years, or until revision. At a mean follow-up of 57 months, modified Harris Hip Scores, Western Ontario McMaster Universities Arthritis Index scores, Short Form-12 physical function scores, and University of California, Los Angeles activity scores improved significantly in all patients. There was no radiographic evidence of osteolysis in any patient. The mean linear polyethylene wear rate was 0.02 mm per year. Survivorship was 98% with one revision for acetabular loosening at 71 months. Total hip arthroplasty in patients 21 years or younger with highly cross-linked polyethylene had excellent clinical and radiographic outcomes at mid-term follow-up. Longer-term data are needed in this patient population to confirm continued survivorship in the extremely young. The level of evidence used for this study was level III.


2001 ◽  
Vol 16 (8) ◽  
pp. 116-121 ◽  
Author(s):  
Haruo Kawamura ◽  
Robert B. Bourne ◽  
Michael J. Dunbar ◽  
Cecil H. Rorabeck

Sign in / Sign up

Export Citation Format

Share Document