Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger

2021 ◽  
Vol 103-B (7 Supple B) ◽  
pp. 78-83 ◽  
Author(s):  
Gordon G. Roedel ◽  
Beau J. Kildow ◽  
Daniel S. Sveom ◽  
Kevin L. Garvin

Aims Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Methods Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis. Results Clinical outcomes showed significant improvement of mean Harris Hip Scores from 52.8 (SD 13.5) preoperatively to 94.8 (SD 7.6) postoperatively. One hip was revised for recurrent instability, and there were no infections. No hips were revised for mechanical loosening or osteolysis. Mean polyethylene linear wear was 0.04 mm/year and volumetric wear was 6.22 mm3/year, with no significant differences between head size or material. Osteolysis was not present in any of the hips. Conclusion The use of HXLPE in THA for patients aged 50 years and younger has performed exceptionally well without evidence of significant wear causing mechanical loosening or necessitating revision. The radiolucent lines of the acetabular component must be followed to determine the prognostic significance. This investigation represents the longest clinical follow-up of a large, consecutive cohort of patients aged 50 years or younger with THA using HXLPE. This long-term analysis found negligible polyethylene wear, no incidence of aseptic loosening, and excellent clinical outcomes at and beyond 15 years of follow-up. Cite this article: Bone Joint J 2021;103-B(7 Supple B):78–83.

2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


2021 ◽  
Vol 2 (12) ◽  
pp. 1035-1042
Author(s):  
Maciej Okowinski ◽  
Mette Holm Hjorth ◽  
Sebastian Breddam Mosegaard ◽  
Jonathan Hugo Jürgens-Lahnstein ◽  
Stig Storgaard Jakobsen ◽  
...  

Aims Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042.


Author(s):  
Matthew Hepinstall ◽  
Harrison Zucker ◽  
Chelsea Matzko ◽  
Morteza Meftah ◽  
Michael Mont

Introduction: Longevity and success of total hip arthroplasty (THA) is largely dependent on component positioning. While use of robotic platforms can improve this positioning, published evidence on its clinical benefits is limited. Therefore, the aim of this study was to assess the clinical outcomes of THA with robotic surgical assistance. Materials and Methods: We conducted an analysis of robotic arm-assisted primary THAs performed by a single surgeon utilizing a posterior approach. A total of 99 patients (107 cases) who had a minimum two-year follow up were identified. Their mean age was 61 years (range, 33 to 84 years), and their mean body mass index was 30.5 kg/m2 (range, 18.5 to 49.1 kg/m2). There were 56% female patients and primary osteoarthritis was the principal hip diagnosis in 88.8%. Operative times, lengths of hospital stay, and discharge dispositions were recorded, along with any complications. Modified Harris Hip Scores (HHS) were calculated to quantify clinical outcomes. Results: Mean postoperative increases in HHS at 2- to 5.7-year follow up was 33 points (range, 6 to 77 points). There were no complications attributable to the use of robotic assistance. Surgical-site complications were rare; one case underwent a revision for prosthetic joint infection (0.93%) but there were no dislocations, periprosthetic fractures, or cases of mechanical implant loosening. There was no evidence of progressive radiolucencies or radiographic failure. Discussion: Robotic arm-assisted THA resulted in low complication rates at minimum two-year follow up, with clinical outcomes comparable to those reported with manual surgery.1–4 The haptically-guided acetabular bone preparation enabled reliable cementless acetabular fixation and there were no adverse events related to the use of the robot. Dislocations were avoided in this case series. Randomized controlled clinical trials are needed to compare manual to robotic surgery and to investigate whether the precision found with this functional planning will reliably reduce the incidence of dislocations.


2021 ◽  
Author(s):  
Takaki Miyagawa ◽  
Kazu Matsumoto ◽  
Shingo Komura ◽  
Haruhiko Akiyama

Abstract Background: We investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analysed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis. Methods: We evaluated 73 hips of 65 patients (6 men and 59 women; mean age at the time of surgery 62.2 years, range 45-86 years) who had undergone THA using a 3D porous titanium cup. Clinical evaluation was performed using the Japanese Orthopaedic Association (JOA) hip score system. We assessed the fixation of the acetabular component based on the presence of radiolucent lines and cup migration using anteroposterior radiographs. Subject-specific FE models were constructed from computed tomography data. Results: The JOA score improved from a preoperative mean of 52.2 (range, 23-82) to a mean of 87.8 (range, 71-100) at the final follow-up. None of the patients underwent revisions during the follow-up period. Radiolucent lines were observed in 26 cases (35.6%) and frequently appeared at DeLee and Charnley Zone 3. In the FE analysis, the micromotion at DeLee and Charnley Zone 3 was significantly larger than that at Zones 1 and 2. Furthermore, micromotion was large in the groups in which radiolucent lines appeared at Zone 3. Conclusions: The mid-term clinical outcome of THA using a 3D porous titanium cup was excellent. However, radiolucent lines frequently appeared at DeLee and Charnley Zone 3. FE analysis indicated that micromotion was large at the same site, strongly suggesting that it contributes to the emergence of radiolucent lines. The 3D porous titanium cups are useful in THA, and with improvements focused on micromotion, we anticipate better long-term outcomes.


2021 ◽  
Vol 6 (9) ◽  
pp. 759-770
Author(s):  
Zeng Li ◽  
Shuai Xiang ◽  
Cuijiao Wu ◽  
Yingzhen Wang ◽  
Xisheng Weng

Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty. The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials. The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE). Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included. Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software. Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower. However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different. The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty. Cite this article: EFORT Open Rev 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072


2020 ◽  
Vol 4 (03) ◽  
pp. 124-128
Author(s):  
David Yeroushalmi ◽  
Katherine A. Lygrisse ◽  
Mohamad Sharan ◽  
Nolan A. Maher ◽  
Joseph D. Zuckerman ◽  
...  

AbstractThe emergence of highly cross-linked polyethylene (HCLPE) has drastically improved survivorship of implants used in total hip arthroplasty (THA), as demonstrated by midterm outcomes. However, there is limited data evaluating long-term outcomes and wear rates of these liners. Therefore, the aim of this study is to evaluate the longest-to-date follow-up of a specific second-generation HCLPE liner, the progression of wear rate, and its relation to acetabular cup positioning. A retrospective study was conducted on patients who underwent THA between January 2001 and December 2005 using a specific second-generation HCLPE liner. Annual liner wear rate (mm/year) was calculated in this group as well as acetabular positioning through abduction angle (degrees). Failures and reason for failures such as periprosthetic fracture, dislocation, and osteolysis were noted when applicable. Forty hips of 35 patients were included in this study with a clinical and radiographic follow-up of 13.4 ± 2.2 years (range: 10.0–16.7 years). Linear and volumetric wear rates were calculated to be 0.037 ± 0.020 mm/year and 22.94 ± 12.07 mm3/year, respectively. No radiographic femoral or acetabular osteolysis was observed in any of the cases. One patient required revision due to complications unrelated to the liner. No significant relationship could be established for acetabular component abduction angle and linear wear rate (p = 0.690, Spearman's rho = 0.03). Our study demonstrates comparable liner wear rates to that of other second-generation HCLPE liners in long-term follow-up. The XLPE liner continues to exhibit minimal progression of linear wear when compared with previous midterm studies and maintains a low rate of postoperative complications requiring revision THA surgery. Further studies are warranted to assess long-term wear and survivorship between this specific liner and comparable HCLPE models.


2020 ◽  
Author(s):  
Sang Min Lee ◽  
Kuen Tak Suh ◽  
Won Chul Shin ◽  
Young Kwang Oh ◽  
Seung Hun Woo

Abstract Background Although hip arthroplasty has become increasingly common, its radiological and clinical outcomes in chronic renal failure patients remain unclear. This study analyzed the outcomes of hip arthroplasty in patients with chronic renal failure undergoing dialysis. Methods Of 2,364 hips undergoing total hip arthroplasty or bipolar hemiarthroplasty between January 2003 and December 2017, data pertaining of 37 hips of patients with chronic renal failure undergoing dialysis (16 men, 21 women) were retrospectively examined. We analyzed the radiological and clinical outcomes of hip arthroplasty, as well as the occurrence of local and general complications (particularly the time of their occurrence) during follow-up and their association with dialysis duration. Results The mean patient age was 60.6 ± 13.5 years, and the mean follow-up duration was 36.6 ± 27.2 months. The mean T-value indicating bone mineral density was -2.62 ± 1.15, with osteoporosis noted in 20 cases. Except for 1 case with infection-induced change in acetabular cup tilt, all cases of total hip arthroplasty with cementless acetabular cup implant exhibited excellent radiographic outcomes. The cementless proximally coated femoral stem was used in all 25 cases of total hip arthroplasty and 7 out of 12 cases of bipolar hemiarthroplasty. Changes in the alignment of femoral stems, subsidence, osteolysis, and loosening were not observed. On clinical assessment, 33 patients received an “excellent” or “good” Harris hip score. Within 1 year postoperatively, complications developed in 18 patients, and some patients exhibited more than 1 complication. More than 1 year after surgery, general complications developed in 12 patients; however, no patient experienced local complications.Conclusions Hip arthroplasty in chronic renal failure patients on dialysis showed excellent radiological and satisfactory clinical outcomes; however, it may be associated with various postoperative complications. Therefore, meticulous preoperative treatment planning and overall postoperative management are required to reduce the risk of complications.