scholarly journals A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study

2018 ◽  
Vol 18 (1) ◽  
Author(s):  
Marc Kriege ◽  
Nina Pirlich ◽  
Thomas Ott ◽  
Eva Wittenmeier ◽  
Frank Dette
2018 ◽  
Vol 37 (5) ◽  
pp. 471-472 ◽  
Author(s):  
Gui-Zhen Yang ◽  
Fu-Shan Xue ◽  
Ya-Yang Liu ◽  
Hui-Xian Li

Medicina ◽  
2019 ◽  
Vol 55 (6) ◽  
pp. 225 ◽  
Author(s):  
Byeong Chul Min ◽  
Jong Eun Park ◽  
Gun Tak Lee ◽  
Tae Rim Kim ◽  
Hee Yoon ◽  
...  

Background and objectives: To compare the first pass success (FPS) rate of the C-MAC video laryngoscope (C-MAC) and conventional Macintosh-type direct laryngoscopy (DL) during cardiopulmonary resuscitation (CPR) in the emergency department (ED). Materials and Methods: This study was a single-center, retrospective study conducted from April 2014 to July 2018. Patients were categorized into either the C-MAC or DL group, according to the device used on the first endotracheal intubation (ETI) attempt. The primary outcome was the FPS rate. A multiple logistic regression model was developed to identify factors related to the FPS. Results: A total of 573 ETIs were performed. Of the eligible cases, 263 and 310 patients were assigned to the C-MAC and DL group, respectively. The overall FPS rate was 75% (n = 431/573). The FPS rate was higher in the C-MAC group than in the DL group, but there was no statistically significant difference (total n = 431, 79% compared to 72%, p = 0.075). In the multiple logistic regression analysis, the C-MAC use had higher FPS rate (adjusted odds ratio: 1.80; 95% CI, 1.17–2.77; p = 0.007) than that of the DL use. Conclusions: The C-MAC use on the first ETI attempt during cardiopulmonary resuscitation in the emergency department had a higher FPS rate than that of the DL use.


2020 ◽  
Vol 46 (5) ◽  
pp. 1039-1045 ◽  
Author(s):  
Wim Breeman ◽  
Mark G. Van Vledder ◽  
Michael H. J. Verhofstad ◽  
Albert Visser ◽  
Esther M. M. Van Lieshout

Abstract Purpose The aim of this study was to compare the rate of first attempt success of endotracheal intubation performed by ambulance nurses in patients with a Glasgow Coma Scale (GCS)  of 3 using video laryngoscopy versus direct laryngoscopy. Methods A prospective cohort study was conducted in a single, independent ambulance service. Twenty of a total of 65 nurse-staffed ambulances were equipped with a video laryngoscope; a classic direct laryngoscope (Macintosh) was available on all 65 ambulances. The primary outcome was first attempt success of the intubation. Secondary outcomes were overall success, time needed for intubation, adverse events, technical or environmental issues encountered, and return of spontaneous circulation (ROSC). Ambulance nurses were asked if the intubation device had affected the outcome of the intubation. Results The first attempt success rate in the video laryngoscopy group [53 of 93 attempts (57%)] did not differ from that in the direct laryngoscopy group [61 of 126 (48%); p = 0.221]. However, the second attempt success rate was higher in the video laryngoscopy group [77/93 (83%) versus 80/126 (63%), p = 0.002]. The median time needed for the intubation (53 versus 56 s) was similar in both groups. Ambulance nurses more often expected a positive effect when performing endotracheal intubation with a video laryngoscope (n = 72, 81%) compared with a direct laryngoscope (n = 49, 52%; p < 0.001). Conclusion Although no significant effect on the first attempt success was found, video laryngoscopy did increase the overall success rate. Ambulance nurses had a more positive valuation of the video laryngoscope with respect to success chances.


2018 ◽  
Vol 37 (5) ◽  
pp. 473 ◽  
Author(s):  
Antoine Giraudon ◽  
Maryline Bordes-Demolis ◽  
François Semjen ◽  
Matthieu Biais ◽  
Karine Nouette-Gaulain

2012 ◽  
Vol 116 (3) ◽  
pp. 622-628 ◽  
Author(s):  
John E. Fiadjoe ◽  
Harshad Gurnaney ◽  
Nicholas Dalesio ◽  
Emily Sussman ◽  
Huaqing Zhao ◽  
...  

Background Intubation in children is increasingly performed using video laryngoscopes. Many pediatric studies examine novice laryngoscopists or describe single patient experiences. This prospective randomized nonblinded equivalence trial compares intubation time for the GlideScope Cobalt® video laryngoscope (GCV, Verathon Medical, Bothell, WA) with direct laryngoscopy with a Miller blade (DL, Heine, Dover, NH) in anatomically normal neonates and infants. The primary hypothesis was that intubation times with GCV would be noninferior to DL. Methods Sixty subjects presenting for elective surgery were randomly assigned to intubation using GCV or DL. Intubation time, time to best view, percentage of glottic opening score, and intubation success were documented. We defined an intubation time difference of less than 10 s as clinically insignificant. Results There was no difference in intubation time between the groups (GCV median = 22.6 s; DL median = 21.4 s; P = 0.24). The 95% one-sided CI for mean difference between the groups was less than 8.3 s. GCV yielded faster time to best view (median = 8.1 s; DL 9.9 s; P = 0.03). Endotracheal tube passage time was longer for GCV (median = 14.3 s; DL 8.5 s; P = 0.007). The percentage of glottic opening score was improved with GCV (median 100; DL 80; P &lt; 0.0001). Conclusions Similar intubation times and success rates were achieved in anatomically normal neonates and infants with the GCV as with DL. The GCV yielded faster time to best view and better views but longer tube passage times than DL.


Sign in / Sign up

Export Citation Format

Share Document