scholarly journals A multiplex PCR assay for the detection of five influenza viruses using a dual priming oligonucleotide system

2015 ◽  
Vol 15 (1) ◽  
Author(s):  
Xuezheng Ma ◽  
Huanzhou Xu ◽  
Lei Shi ◽  
Pengfei Yang ◽  
Liping Zhang ◽  
...  
Gene Reports ◽  
2021 ◽  
Vol 23 ◽  
pp. 101158
Author(s):  
SiouNing Aileen See ◽  
Zee Hong Goh ◽  
Yen Yew Chan ◽  
Khai En Chong ◽  
Geok Yuan Annie Tan ◽  
...  

2013 ◽  
Vol 62 (11) ◽  
pp. 1673-1679 ◽  
Author(s):  
Lucrecia Carrara ◽  
Ferran Navarro ◽  
Miquel Turbau ◽  
Montse Seres ◽  
Indalecio Morán ◽  
...  

Mortality from bloodstream infections (BSIs) correlates with diagnostic delay and the use of inappropriate empirical treatment. Early PCR-based diagnosis could decrease inappropriate treatment, improving patient outcome. The aim of the present study was to assess the clinical utility of this molecular technology to diagnose BSIs. We assessed a new dual-priming oligonucleotide-based multiplex PCR assay, the Magicplex Sepsis Test (MST) (Seegene), along with blood culture (BC). A total of 267 patients from the intensive care unit and haematology and emergency departments were enrolled. Clinical data were also used by physicians to determine the likelihood of infection. Ninety-eight (37 %) specimens were positive: 29 (11 %) by both the MST and BC, 29 (11 %) by the MST only, and 40 (15 %) by BC only. The proportion of agreement between the two methods was 73 % (Cohen’s κ: 0.45; 0.28–0.6; indicating fair to moderate agreement). According to clinical assessment, 63 (64 %) positive specimens were considered BSIs: 23 (36 %) were positive by both the MST and BC, 22 (35 %) were positive only by BC, and 18 (29 %) were positive only by the MST. Thirty-eight (14 %) positive specimens by the MST and/or BC were considered as contaminants. Of 101 specimens collected from patients receiving antibiotics, 20 (20 %) were positive by the MST and 32 (32 %) by BC. Sensitivity and specificity were 65 % and 92 %, respectively, for the MST and 71 % and 88 %, respectively for BC. We concluded that the MST shows a high specificity but changes in design are needed to increase bacteraemia detection. For viability in clinical laboratories, technical improvements are also required to further automate the process.


2016 ◽  
Vol 1 (2) ◽  
pp. 38-42 ◽  
Author(s):  
Khairun Nessa ◽  
Dilruba Ahmed ◽  
Johirul Islam ◽  
FM Lutful Kabir ◽  
M Anowar Hossain

A multiplex PCR assay was evaluated for diagnosis of diarrheagenic Escherichia coli in stool samples of patients with diarrhoea submitted to a diagnostic microbiology laboratory. Two procedures of DNA template preparationproteinase K buffer method and the boiling method were evaluated to examine isolates of E. coli from 150 selected diarrhoeal cases. By proteinase K buffer method, 119 strains (79.3%) of E. coli were characterized to various categories by their genes that included 55.5% enteroaggregative E. coli (EAEC), 18.5% enterotoxigenic E. coli (ETEC), 1.7% enteropathogenic E. coli (EPEC), and 0.8% Shiga toxin-producing E. coli (STEC). Although boiling method was less time consuming (<24 hrs) and less costly (<8.0 US $/ per test) but was less efficient in typing E. coli compared to proteinase K method (41.3% vs. 79.3% ; p<0.001). The sensitivity and specificity of boiling method compared to proteinase K method was 48.7% and 87.1% while the positive and negative predictive value was 93.5% and 30.7%, respectively. The majority of pathogenic E. coli were detected in children (78.0%) under five years age with 53.3% under one year, and 68.7% of the children were male. Children under 5 years age were frequently infected with EAEC (71.6%) compared to ETEC (24.3%), EPEC (2.7%) and STEC (1.4%). The multiplex PCR assay could be effectively used as a rapid diagnostic tool for characterization of diarrheagenic E. coli using a single reaction tube in the clinical laboratory setting.Bangladesh J Med Microbiol 2007; 01 (02): 38-42


Author(s):  
Sunarno ◽  
Khariri ◽  
Fauzul Muna ◽  
Kambang Sariadji ◽  
Yuni Rukminiati ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document