scholarly journals Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Hoorak Poorzand ◽  
Mohammad Tayyebi ◽  
Sara Hosseini ◽  
Alireza Heidari Bakavoli ◽  
Faeze Keihanian ◽  
...  

Abstract Background The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature. Methods We prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location. Results Lead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative. Conclusion The RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up.

EP Europace ◽  
2020 ◽  
Vol 22 (10) ◽  
pp. 1520-1525 ◽  
Author(s):  
Waddah Maskoun ◽  
Mohamad Raad ◽  
Arfaat Khan ◽  
Ramy Mando ◽  
Mohamed Homsi

Abstract Aims Right ventricular (RV) lead placement can be contraindicated in patients after tricuspid valve (TV) surgery. Placement of the implantable cardiac-defibrillator (ICD) lead in the middle cardiac vein (MCV) can be a viable option in these patients who have an indication for biventricular (BiV) ICD. We aim to describe the case of two patients with MCV lead placement and provide a comprehensive review of patients with complex TV pathology and indications for RV lead placement. Methods and results We describe the cases of two patients with TV pathology unsuitable for the standard transvenous or surgical RV lead placement and undergoing BiV ICD implantation. Their characteristics, procedure, and outcomes are summarized. The BiV ICD was successfully placed with the RV lead positioned in the MCV in both patients. The procedures had no complications and were well-tolerated. On follow-up, both patients had appropriate tachytherapy with no readmissions for heart failure or worsening of cardiac function. Conclusion Right ventricular lead placement of BiV ICD in the MCV can be an excellent alternative in patients with significant TV pathology and poor surgical candidacy.


2019 ◽  
Vol 73 (9) ◽  
pp. 2449
Author(s):  
Thomas Flautt ◽  
Alison Spangler ◽  
Sandra Charlton ◽  
John Prather ◽  
Frank McGrew

2014 ◽  
Vol 63 (12) ◽  
pp. A383
Author(s):  
Anil H. Punjabi ◽  
George Thomas ◽  
Jim Cheung ◽  
Christopher Liu ◽  
Bruce Lerman ◽  
...  

2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Paolo Vitillo ◽  
Francesca Esposito ◽  
Francesco Rotondi ◽  
Felice Nappi ◽  
Francesco Urraro ◽  
...  

Abstract Methods and results A 58 years-old man was admitted to our intensive care unit for syncope due to inconstant capture of epicardial ventricular lead. His cardiovascular history began 20 years before when he underwent single chamber pacemaker implantation with insertion of a passive fixation ventricular lead for symptomatic complete atrio ventricular block (AVB). Electrical parameters were good at implantation. However, during follow-up a gradual and progressive increase of pacing threshold occurred, with no changes in impedance values, finally leading to complete loss of ventricular capture. Hence, 2 years later, the lead was extracted and a new transvenous ventricular lead was placed in septal position. All electrical parameters were optimal at the end of the procedure. However, in the following months threshold values gradually increased as previously observed. The referring clinicians decided to surgically extract both the device and transvenous lead and to implant an epicardial ventricular lead connected to an abdominal generator. The pacemaker worked properly for about 17 years until he was transferred to our institution with evidence of inconstant lead capture at maximum pacing outputs. A temporary transvenous pacemaker was immediately inserted. Clinical examination, laboratory exams, and echocardiography were normal. Cardiac magnetic resonance (MRI) was not feasible due to the epicardial lead. Thus, in order to obtain cardiac substrate characterization, we decided to perform high density multielectrode voltage mapping of the right ventricular endocardium with HD Grid multielectrode mapping catheter (HD Grid mapping catheter sensor enabled, Abbott Technologies, Minneapolis, MN). Electroanatomic voltage map allows distinction of areas of healthy myocardium (&gt;1.5 mV) from scar tissue (&lt;0.5 mV). Unexpectedly, voltage mapping highlighted no scar zones, showing a globally normal endomyocardial surface. Therefore, a new endocavitary pacemaker was inserted in right prepectoral region and an active fixation right ventricular lead was placed on mid-ventricular septum. A backup pacing lead was placed in a more apical position in an area of endocardial healthy myocardium. Post-procedural sensing, impedance and capture threshold were optimal (0.3 V × 0.4 ms for mid-septal lead and 0.3 × 0.4 ms for the other one). At 1 month follow-up mid-septal lead’s threshold was slightly increased (1.0 V × 0.4 ms) and further increase was observed at 3-month outpatient visit (1.75 V × 0.4 ms). Capture threshold of the other lead and other parameters were stable. The patient received remote monitoring for home surveillance of the implanted system. Home monitoring shows a trend toward a progressive increase of pacing threshold of the mid-septal lead and stable value of the other electrode. Conclusions The present report suggests an innovative use of high-density mapping with HD Grid catheter to characterize endocardial right ventricular myocardium in a patient with contraindication to cardiac MRI and recurrent failure of previous implanted pacing systems for unknown reason and to guide effective lead placement in areas of normal endocardial voltage. Combined use of telemedicine and high-resolution mapping technique allowed us to avoid unnecessary high risk reintervention for novel epicardial lead placement.


2021 ◽  
Vol 10 (11) ◽  
pp. 2266
Author(s):  
Matthias Schneider ◽  
Varius Dannenberg ◽  
Andreas König ◽  
Welf Geller ◽  
Thomas Binder ◽  
...  

Background: Presence of severe tricuspid regurgitation (TR) has a significant impact on assessment of right ventricular function (RVF) in transthoracic echocardiography (TTE). High trans-valvular pendulous volume leads to backward-unloading of the right ventricle. Consequently, established cut-offs for normal systolic performance may overestimate true systolic RVF. Methods: A retrospective analysis was performed entailing all patients who underwent TTE at our institution between 1 January 2013 and 31 December 2016. Only patients with normal left ventricular systolic function and with no other valvular lesion were included. All recorded loops were re-read by one experienced examiner. Patients without severe TR (defined as vena contracta width ≥7 mm) were excluded. All-cause 2-year mortality was chosen as the end-point. The prognostic value of several RVF parameters was tested. Results: The final cohort consisted of 220 patients, 88/220 (40%) were male. Median age was 69 years (IQR 52–79), all-cause two-year mortality was 29%, median TAPSE was 19 mm (15–22) and median FAC was 42% (30–52). In multivariate analysis, TAPSE with the cutoff 17 mm and FAC with the cutoff 35% revealed non-significant hazard ratios (HR) of 0.75 (95%CI 0.396–1.421, p = 0.38) and 0.845 (95%CI 0.383–1.867, p = 0.68), respectively. TAPSE with the cutoff 19 mm and visual eyeballing significantly predicted survival with HRs of 0.512 (95%CI 0.296–0.886, p = 0.017) and 1.631 (95%CI 1.101–2.416, p = 0.015), respectively. Conclusions: This large-scale all-comer study confirms that RVF is one of the main drivers of mortality in patients with severe isolated TR. However, the current cut-offs for established echocardiographic parameters did not predict survival. Further studies should investigate the prognostic value of higher thresholds for RVF parameters in these patients.


2006 ◽  
Vol 23 (9) ◽  
pp. 793-800 ◽  
Author(s):  
Dasan E. Velayudhan ◽  
Todd M. Brown ◽  
Navin C. Nanda ◽  
Vinod Patel ◽  
Andrew P. Miller ◽  
...  

2021 ◽  
Vol 10 (21) ◽  
pp. 5080
Author(s):  
Elda Dzilic ◽  
Thomas Guenther ◽  
Amel Bouziani ◽  
Bernhard Voss ◽  
Stephanie Voss ◽  
...  

Background: Tricuspid valve (TV) repair is the recommended treatment for severe functional tricuspid regurgitation (fTR) in patients undergoing left-sided surgery. For this purpose, a wide range of annuloplasty devices differing in form and flexibility are available. This study reports the results using a three-dimensional annuloplasty ring (Medtronic, Contour 3D Ring) for TV repair and analysis of risk factors. Methods: A cohort of 468 patients who underwent TV repair (TVr) with a concomitant cardiac procedure from December 2010 to January 2017 was retrospectively analyzed. Results: At follow-up, 96.1% of patients had no/trivial or mild TR. The 30-day mortality was 4.7%; it significantly differed between electively performed operations (2.7%) and urgent/emergent operations (11.7%). Risk factors for recurrent moderate and severe TR were LVEF < 50%, TAPSE < 16 mm, and moderate mitral valve (MV) regurgitation at follow-up. Preoperatively reduced renal function lead to a higher 30-day and overall mortality. Reoperation of the TV was required in six patients (1.6%). Risk factors for TV related reoperations were preoperative TV annulus over 50 mm and an implanted permanent pacemaker. Conclusions: TVr with the Contour 3D annuloplasty ring shows low TR recurrence and reoperation rates. Risk-factor analysis for the recurrence of TR revealed the importance of left- and right-ventricular function.