scholarly journals Evaluation of SARS-CoV-2 antigen-based rapid diagnostic kits in Pakistan: formulation of COVID-19 national testing strategy

2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Umar Saeed ◽  
Sara Rizwan Uppal ◽  
Zahra Zahid Piracha ◽  
Azhar Rasheed ◽  
Zubair Aftab ◽  
...  

AbstractRapid diagnosis of SARS-CoV-2 during pandemic enables timely treatment and prevention of COVID-19. Evaluating the accuracy and reliability of rapid diagnostic testing kits is crucial for surveillance and diagnosis of SARS-CoV-2 infections in general population, injection drug users, multi-transfused populations, healthcare workers, prisoners, barbers and other high risk populations. The aim of this study was to evaluate performance and effectiveness of nasopharyngeal swab (NSP) and saliva based rapid antigen detection testing kits in comparison with USFDA approved triple target gold standard real-time polymerase chain reaction. A cross-sectional study was conducted on 33,000 COVID-19 suspected patients. From RT-PCR positive patients, nasopharyngeal swab (NSP) and saliva samples were obtained for evaluation of rapid COVID-19 testing kits (RDT). 100/33,000 (0.3%) of specimens were RT-PCR positive for SARS-CoV-2. Among RT-PCR positive, 62% were males, 34% were females, and 4% were children. The NSP-RDT (Lepu Medical China) analysis revealed 53% reactivity among males, 58% reactivity among females, and 25% reactivity among children. However saliva based RDT (Lepu Medical China) analysis showed 21% reactivity among males and 23% among females, and no reactivity in children. False negative results were significantly more pronounced in saliva based RDT as compared to NSP-RDT. The sensitivity of these NSP-RDT and saliva based RDT were 52% and 21% respectively. The RDTs evaluated in this study showed limited sensitivities in comparison to gold standard RT-PCR, indicating that there is a dire need in Pakistan for development of suitable testing to improve accurate COVID-19 diagnosis in line with national demands.

2021 ◽  
Author(s):  
Umar Saeed ◽  
Sara Rizwan Uppal ◽  
Zahra Zahid Piracha ◽  
Azhar Rasheed ◽  
Zubair Aftab ◽  
...  

Abstract Rapid diagnosis of SARS-CoV-2 during pandemic enables timely treatment and prevention of COVID-19. Evaluating the accuracy and reliability of rapid diagnostic testing kits is crucial for surveillance and diagnosis of SARS-CoV-2 infections in general population, injection drug users, multi-transfused populations, healthcare workers, prisoners, barbers and other high risk populations. The aim of this study was to evaluate performance and effectiveness of nasopharyngeal swab (NSP) and saliva based rapid antigen detection testing kits in comparison with USFDA approved triple target gold standard real-time polymerase chain reaction. A cross-sectional study was conducted on 33,000 COVID-19 suspected patients. From RT-PCR positive patients, nasopharyngeal swab (NSP) and saliva samples were obtained for evaluation of rapid COVID-19 testing kits (RDT). 100/33000 (0.3%) of specimens were RT-PCR positive for SARS-CoV-2. Among RT-PCR positive, 62% were males, 34% were females, and 4% were children. The NSP-RDT (Lepu Medical China) analysis revealed 53% reactivity among males, 58% reactivity among females, and 25% reactivity among children. However saliva based RDT (Lepu Medical China) analysis showed 21% reactivity among males and 23% among females, and no reactivity in children. False negative results were significantly more pronounced in saliva based RDT as compared to NSP-RDT. The sensitivity of these NSP-RDT and saliva based RDT were 52% and 21% respectively. The RDTs evaluated in this study showed limited sensitivities in comparison to gold standard RT-PCR, indicating that there is a dire need in Pakistan for development of suitable testing to improve accurate COVID-19 diagnosis in line with national demands.


2020 ◽  
Author(s):  
Umar Saeed ◽  
Sara Rizwan Uppal ◽  
Zahra Zahid Piracha ◽  
Azhar Rasheed ◽  
Zubair Aftab ◽  
...  

Abstract Rapid diagnosis of SARS-CoV-2 during pandemic enables timely treatment and prevention of COVID-19. Evaluating the accuracy and reliability of rapid diagnostic testing kits is crucial for surveillance and diagnosis of SARS-CoV-2 infections in general population, injection drug users, multi-transfused populations, healthcare workers, prisoners, barbers and other high risk populations. The aim of this study was to evaluate performance and effectiveness of nasopharyngeal swab (NSP) and saliva based rapid antigen detection testing kits in comparison with USFDA approved triple target gold standard real-time polymerase chain reaction. A cross-sectional sectional study was conducted on 33,000 COVID-19 suspected patients. From RT-PCR positive patients, nasopharyngeal swab (NSP) and saliva samples were obtained for evaluation of rapid COVID-19 testing kits (RDT). 100/33000 (0.3%) of specimens were RT-PCR positive for SARS-CoV-2. Among RT-PCR positive, 62% were males, 34% were females, and 4% were children. The NSP-RDT (Lepu Medical China) analysis revealed 53% reactivity among males, 58% reactivity among females, and 25% reactivity among children. However saliva based RDT (Lepu Medical China) analysis showed 21% reactivity among males and 23% among females, and no reactivity in children. False negative results were significantly more pronounced in saliva based RDT as compared to NSP-RDT. The sensitivity of these NSP-RDT and saliva based RDT were 52% and 21% respectively. The RDTs evaluated in this study showed limited sensitivities in comparison to gold standard RT-PCR, indicating that there is a dire need in Pakistan for development of suitable testing to improve accurate COVID-19 diagnosis in line with national demands.


Author(s):  
Umar Saeed ◽  
Sara Rizwan Uppal ◽  
Zahra Zahid Piracha ◽  
Aftab Ahmad Khan ◽  
Azhar Rasheed ◽  
...  

Abstract COVID-19 pandemic has urged the need of rapid detection of SARS-CoV-2 in limited time frame. To cope with current, COVID-19 expanding scenario, accurate diagnosis of SARS-CoV-2 should be ensured by both national and international health organizations. Sporadic marketing of SARS-CoV-2 rapid detection kits raises questions regarding quality control and assurance. To aim of this study was to examine the effectiveness of SARS-CoV-2 nasopharyngeal swab based rapid detection kits, in comparison to gold standard USFDA approved triple target real-time polymerase chain reaction. A cross-sectional study of 1500 suspected COVID-19 patients was conducted. 100 RT-PCR confirmed patients nasopharyngeal swabs were evaluated for RDT. The COVID-19/SARS-CoV-2 NSP based RDT analysis showed 78% reactivity. Among RT-PCR confirmed negative subjects, 49.3% showed false positivity. The positive predictive analysis revealed 67.82% values, while the negative predictive vales of were 64.40%. The NSP RDTs showed limited sensitivities and specificities compared to gold standard RT-PCR. Accurate surveillance of COVID-19 is dependent upon authentic and validated SARS-CoV-2 detection nation-wide, which needs to be monitored by higher authorities. This study is critical for designing adequate measures by several COVID-19 strategic organizations to prevent future viral epidemics.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.


Author(s):  
Marco Marando ◽  
Adriana Tamburello ◽  
Pietro Gianella

On 11 March 2020, the WHO declared COVID-19 a pandemic and global health emergency. We describe the clinical features and role of ultra-low-dose chest computed tomography (CT) and bronchoscopy in the diagnosis of coronavirus disease (COVID-19). In our patient, who was highly suggestive clinically and radiologically for COVID-19, we had two false-negative results for nasopharyngeal and oral swab reverse-transcriptase polymerase chain reaction (RT-PCR) assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Eventually, we confirmed the diagnosis using bronchoscopy and bronchoalveolar lavage (BAL).


2020 ◽  
Vol 66 (9) ◽  
pp. 1258-1263
Author(s):  
Hamad Dheir ◽  
Savas Sipahi ◽  
Selcuk Yaylaci ◽  
Ahmed Cihad Genc ◽  
Fevziye Turkoglu Genc ◽  
...  

SUMMARY INTRODUCTION: This study aims to determine the incidence of de novo nephritic syndrome (NS) in COVID-19 patients and identify its associated factors. METHODS: All ward patients with COVID-19 pneumonia were investigated. After determining the inclusion and exclusion criteria, the study population was identified. The urine dipstick test and urine protein creatinine ratio (UPCR) measurements were performed. Patients with de novo NS findings, nasopharyngeal swab, and urine RT-PCR tests were performed simultaneously RESULTS: This descriptive cross-sectional study was conducted with 21 patients with COVID-19. The mean age of the patients was 42.2±8.8 years, and 71.4% of them were male. The mean duration of follow-up was 28.4±9.3 days. The urine RT-PCR test was positive in one patient (4.8%). Improvements were observed in hematuria by 71.4%, and proteinuria by 85.7% at the end of the follow-up. A significant decrease in the measured UPCR was found in comparison to the baseline(P=0.000). Also, improvements were recorded in the complete blood counts, inflammatory parameters, ferritin, and coagulation tests, compared to the baseline. There was a positive correlation between baseline UPCR and ferritin, and a negative correlation between baseline UPCR and sodium values CONCLUSION: COVID-19-induced de novo nephritic syndrome may occur mainly due to tubulointerstitial involvement and often results in spontaneous remission. However, why these findings were not present in all patients who had no comorbidities is not clear.


Sign in / Sign up

Export Citation Format

Share Document