scholarly journals Superiority of MALDI-TOF Mass Spectrometry over Real-Time PCR for SARS-CoV-2 RNA Detection

Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.

2021 ◽  
Author(s):  
Lu Wang ◽  
Xueqing Liu ◽  
Chen Xia ◽  
Jun Liu ◽  
Xiao-Hua Zhou

Abstract In this article, we propose a novel statistical method for estimating the accuracy of chest computed tomography (CT) and reverse transcription polymerase chain reaction (RT-PCR) tests in the diagnosis of coronavirus disease 2019 (COVID-19), with a correction for imperfect gold standard and verification bias simultaneously. These two types of bias are often involved in estimating the diagnostic accuracy of COVID-19 tests. Imperfect gold standard bias arises when estimating accuracy measures of chest CT while using the RT-PCR test as a gold standard, despite its tendency to produce false negative results. Meanwhile, verification bias occurs in some studies where the results from chest CT are verified by RT-PCR test in a subsample of suspected cases that is not representative of the original population. Consequently, the accuracy estimates of chest CT and RT-PCR tests could be seriously biased and lead to invalid inference. Our proposed method is able to correct these two types of bias in providing unbiased and more accurate estimates of sensitivity and specificity of the two tests. Our results suggest that chest CT has higher sensitivity and lower specificity than RT-PCR, and the accuracy estimates can serve as an important reference for assessing and comparing the performance of these two tests in the diagnosis of COVID-19, and could guide policy recommendations for the implementation of these tests.


2020 ◽  
Vol 9 (3) ◽  
pp. 408-410
Author(s):  
Fatemeh Bahreini ◽  
Rezvan Najafi ◽  
Razieh Amini ◽  
Salman Khazaei ◽  
Saeid Bashirian

As the SARS-CoV-2 (COVID-19) pandemic spreads rapidly, there is need for a diagnostic test with high accuracy to detect infected individuals especially those without symptoms. Real-time polymerase chain reaction (RT-PCR) is a common molecular test for diagnosing SARS-CoV-2. If some factors are not taken into consideration when performing this test, it can have a relatively large number of false negative results. In this article, we discuss important considerations that could lead to false negative test reduction. Key words: • SARS-CoV-2 • COVID-19 • Real time polymerase chain reaction • RT-PCR test • Diagnosis • False negatives • Genetics • Emerging disease   Copyright © 2020 Bahreini et al. Published by Global Health and Education Projects, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0)which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in this journal, is properly cited.


2021 ◽  
Author(s):  
Matthew M. Hernandez ◽  
Radhika Banu ◽  
Ana S. Gonzalez-Reiche ◽  
Adriana van de Guchte ◽  
Zenab Khan ◽  
...  

The COVID-19 pandemic sparked rapid development of SARS-CoV-2 diagnostics. However, emerging variants pose the risk for target dropout and false-negative results secondary to primer/probe binding site (PBS) mismatches. The Agena MassARRAY SARS-CoV-2 Panel combines RT-PCR and MALDI-TOF mass-spectrometry to probe for five targets across N and ORF1ab genes, which provides a robust platform to accommodate PBS mismatches in divergent viruses. Herein, we utilize a deidentified dataset of 1,262 SARS-CoV-2-positive specimens from Mount Sinai Health System (New York City) from December 2020 through April 2021 to evaluate target results and corresponding sequencing data. Overall, the level of PBS mismatches was greater in specimens with target dropout. Of specimens with N3 target dropout, 57% harbored an A28095T substitution that is highly-specific for the alpha (B.1.1.7) variant of concern. These data highlight the benefit of redundancy in target design and the potential for target performance to illuminate the dynamics of circulating SARS-CoV-2 variants.


Pharmacia ◽  
2021 ◽  
Vol 68 (1) ◽  
pp. 155-161
Author(s):  
Maria Georgieva Moneva-Sakelarieva ◽  
Yozlem Ali Kobakova ◽  
Petar Yordanov Atanasov ◽  
Danka Petrova Obreshkova ◽  
Stefka Achkova Ivanova ◽  
...  

The new pandemic disease COVID is quick spread worldwide.The primary method used for diagnosing of COVID-19 is detecting viral nucleic acids. The main problem with RT-PCR test is the false negative results. The negative RT-PCR does not exclude a SARS-CoV-2 infection and this method should not be used as the only diagnostic criteria. The RT-PCR result does not change the complex treatment of the disease. The aim of the current study is to compare the four groups clinical cases of the different parameters: RT-PCR test, rapid test, clinical picture, laboratory tests as hematology, inflammatory markers, coagulation status and chemistry and imaging examinations: Chest X-ray at and Chest CT scan. Complex therapeutic approach has been implemented: antibiotic, inflammatory, anticoagulants, oxygen therapy, hepatoprotectors, antimycotics, fibrinolytics, probiotics, essential oils, vitamins. During the follow-up period, a tendency for significant reduction and resorption of the pulmonary changes on the CT scans has been seen.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Umar Saeed ◽  
Sara Rizwan Uppal ◽  
Zahra Zahid Piracha ◽  
Azhar Rasheed ◽  
Zubair Aftab ◽  
...  

AbstractRapid diagnosis of SARS-CoV-2 during pandemic enables timely treatment and prevention of COVID-19. Evaluating the accuracy and reliability of rapid diagnostic testing kits is crucial for surveillance and diagnosis of SARS-CoV-2 infections in general population, injection drug users, multi-transfused populations, healthcare workers, prisoners, barbers and other high risk populations. The aim of this study was to evaluate performance and effectiveness of nasopharyngeal swab (NSP) and saliva based rapid antigen detection testing kits in comparison with USFDA approved triple target gold standard real-time polymerase chain reaction. A cross-sectional study was conducted on 33,000 COVID-19 suspected patients. From RT-PCR positive patients, nasopharyngeal swab (NSP) and saliva samples were obtained for evaluation of rapid COVID-19 testing kits (RDT). 100/33,000 (0.3%) of specimens were RT-PCR positive for SARS-CoV-2. Among RT-PCR positive, 62% were males, 34% were females, and 4% were children. The NSP-RDT (Lepu Medical China) analysis revealed 53% reactivity among males, 58% reactivity among females, and 25% reactivity among children. However saliva based RDT (Lepu Medical China) analysis showed 21% reactivity among males and 23% among females, and no reactivity in children. False negative results were significantly more pronounced in saliva based RDT as compared to NSP-RDT. The sensitivity of these NSP-RDT and saliva based RDT were 52% and 21% respectively. The RDTs evaluated in this study showed limited sensitivities in comparison to gold standard RT-PCR, indicating that there is a dire need in Pakistan for development of suitable testing to improve accurate COVID-19 diagnosis in line with national demands.


2020 ◽  
Vol 154 (4) ◽  
pp. 479-485 ◽  
Author(s):  
Blake W Buchan ◽  
Jessica S Hoff ◽  
Cameron G Gmehlin ◽  
Adriana Perez ◽  
Matthew L Faron ◽  
...  

Abstract Objectives We examined the distribution of reverse transcription polymerase chain reaction (RT-PCR) cycle threshold (CT) values obtained from symptomatic patients being evaluated for coronavirus disease 2019 (COVID-19) to determine the proportion of specimens containing a viral load near the assay limit of detection (LoD) to gain practical insight to the risk of false-negative results. We also examined the relationship between CT value and patient age to determine any age-dependent difference in viral load or test sensitivity. Methods We collected CT values obtained from the cobas severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) assay corresponding to 1,213 combined nasopharyngeal-oropharyngeal specimens obtained from symptomatic individuals that were reported as positive or presumptive positive for SARS-CoV-2. CT values were stratified by SARS-CoV target and patient age group. Results In total, 93.3% to 98.4% of specimens demonstrated CT values greater than 3× the assay LoD, at which point false-negative results would not be expected. The mean of CT values between age groups was statistically equivalent with the exception of patients in age group 80 to 89 years, which demonstrated slightly lower CTs. Conclusions Based on the distribution of observed CT values, including the small proportion of specimens with values near the assay LoD, there is a low risk of false-negative RT-PCR results in combined nasopharyngeal-oropharyngeal specimens obtained from symptomatic individuals.


2020 ◽  
Author(s):  
Giselle Ibette Lopez-Lopes ◽  
Rita de Cassia Compagnoli Carmona ◽  
Valéria Oliveira Silva ◽  
Cintia Mayumi Ahagon ◽  
Lincoln Spinazola do Prado ◽  
...  

1AbstractBackgroundSurveillance of COVID infection and isolation of infected individuals is one of the available tools to control the spread of SAR-CoV-2. Asymptomatic and pre symptomatic are responsible for substantial transmission. RNA or antigen tests are necessary to identify non-symptomatic individuals. We tested the feasibility of using samples pooling offering different collection alternatives (swab/throat wash/saliva) to volunteers of a public health institute.MethodsWe evaluated pool samples from frozen material from previously tested samples and a prospective collection from asymptomatic volunteers. Some collections were paired for comparison. Pools and some individual samples were extracted with QIAamp Viral RNA Mini Kit (Qiagen, USA) and/or Lucigen Quick Extract DNA extraction solution (BioSearch, USA) and submitted to rtPCR (Allplex, Seegene, Korea).ResultsA total of 240 samples from 130 new collections and 37 samples with known result were evaluated. Pool CT was generally higher than individual samples. Lucigen extraction showed higher CT, including false negative results for samples with high CT at Qiagen extraction. Paired Swab and TW samples showed comparable results. No volunteer from negative pools reported any symptom in the 2-3 days after collection.ConclusionsClinical samples pooling to detect SARS-CoV-2 RNA is feasible and an economical way to test for COVID-19, especially in surveillance strategies targeting more infectiousness, higher viremia individuals. The use of Lucigen reagents show lower sensibility that may lead to false negative results with lower viremia samples. Combining throat wash with saliva may provide and interesting self-collection alternative, but more comparative work is needed.


Sign in / Sign up

Export Citation Format

Share Document