scholarly journals Intelligent electrical equipment fiber Bragg grating temperature measurement system

Author(s):  
Anhua Peng ◽  
Chengwen Liu ◽  
Le Yang

AbstractFiber Bragg gratings are widely used in electrical equipment monitoring, structural health monitoring, power system fault monitoring and other actual detection occasions due to the unique advantages of anti-electromagnetic interference, low fusion loss, high sensitivity, small size, and easy distributed measurement. Fiber grating has been widely used in actual detection occasions such as electrical equipment monitoring, structural health monitoring, and power system fault monitoring. The temperature measurement of the motor based on fiber grating sensing technology not only has strong anti-electromagnetic interference ability, but also can realize multi-point distributed temperature measurement. The research of fiber grating temperature measurement system for intelligent electrical equipment is of great significance. This article mainly studies the optical fiber grating temperature measurement system of intelligent electrical equipment. This paper designs the temperature measurement system architecture, including data acquisition layer, data monitoring layer and remote monitoring layer. Complete the system design from two aspects: hardware design and software design. In the hardware part, the functions of the temperature sensor module transmission system, signal demodulation system, PLC and host computer are analyzed. Use FTM3501 fiber temperature converter is used to realize the automatic electrical fiber grating. Experimental results show that the thermometer has alarm and display analysis functions. The measurement uncertainty is analyzed, and the uncertainty of the calibration result of the fiber Bragg grating temperature sensor is 0.0725 °C; the fault judgment time of the system in this paper does not exceed 4.73 s, while the fault judgment time of the control group is more than 4.73 s. Compared with the control group, it has a faster fault accuracy speed. The system has high measurement accuracy and good stability, can be applied to actual temperature measurement systems, and has certain practical value.

2014 ◽  
Vol 1070-1072 ◽  
pp. 1167-1170
Author(s):  
Liang Zou ◽  
Xiu Qun Zhang ◽  
Xin Hua Zhao ◽  
Chun Tian ◽  
Hui Duan

In order to study the electromagnetic interference on SAW (surface acoustic wave) wireless temperature measurement system of the corona discharge, the paper analyzes the characteristics of the frequency spectrum of corona discharge, models the corona discharge and studies its radiation characteristics by simulation on Matlab. Based on this, the experimental platforms of corona discharge is set up. The result of the experiment confirms that corona discharge causes electromagnetic interference to the system and the influence decreases as the distance between the sensor and discharge sources increase. Then the sensor should be kept a certain distance from the discharge sources.


2014 ◽  
Vol 539 ◽  
pp. 177-180 ◽  
Author(s):  
Yi Zhen Nie

for Pt100 platinum resistance temperature measurement system has low accuracy, duplicate hardware circuit design and other issues, the articles design a high-precision temperature measurement system with Pt100 platinum resistance. With Pt100 temperature sensor, article takes STM32F103 as the control center through filtering, amplification and other signal conditioning circuit and a method of combining software look-up table to compensate the nonlinear compensation, thus achieving high-precision temperature measurement. Research results show that the system has a measurement accuracy high stability, scalability, and other characteristics.


2013 ◽  
Vol 805-806 ◽  
pp. 1046-1053
Author(s):  
Hai Fang Yue ◽  
Jie Lou

The passive wireless temperature measurement system based on SAW is a better method than the fiber optic and the infrared temperature measurement in measuring the temperature of electrical equipment, but the environmental characteristics have an effect on it. In this paper, the effects of open space and closed space on the system are studied by experiments. The open space has a greater effect on temperature measuring signal because of the polarization direction of the antenna; In the closed space of the metal cabinet, whether there is sheet metallic object near the senor or not, it has no effects on the signal, which is mainly because that the reflections of electromagnetic signals by the internal walls of the metal cabinet make the signal power enhanced between the reader and the sensor through multi-angle reflections. Therefore, this type of measurement system is more suitable for the metallic objects in metal cabinet.


2012 ◽  
Vol 591-593 ◽  
pp. 1502-1505
Author(s):  
Xiang Hong Cao ◽  
Chao Yang ◽  
Hua Zhang

There are many limits in the traditional temperature measurement methods' for high voltage electrical equipment. A wireless temperature measurement system based on C8051F340 for high voltage electrical equipment has been designed, which transfers temperature data by wireless communication, and optimizes the system's power supply for the high voltage electrical equipment's working environment. The host computer of the system analysis the temperature data from wireless sensor and can prevent the equipment's overheat accidents in effect. According to the experiment board's practical operating, this system measures temperature accurately, transfers data stably, operates with a reliable power supply and can meet the practical requirements.


Sign in / Sign up

Export Citation Format

Share Document