scholarly journals Development and Validation of Stability Indicating RP-HPLC Method for the Estimation of Cinacalcet Hydrochloride in Bulk and Their Formulations

2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.

2013 ◽  
Vol 49 (2) ◽  
pp. 359-366 ◽  
Author(s):  
Mustafa Çelebier ◽  
Tuba Reçber ◽  
Engin Koçak ◽  
Sacide Altinöz

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (04) ◽  
pp. 77-80
Author(s):  
M Vijaya Lakshmi ◽  
◽  
K Hima Bindu ◽  
M. Pravallika ◽  
B. N. Nalluri

A simple and precise RP-HPLC method has been developed and validated for the estimation of sarpogrelate hydrochloride, an anti-platelet drug in bulk and pharmaceutical dosage forms. Sarpogrelate is an antagonist at 5HT2A and 5HT2B receptors which blocks serotonin induced platelet aggregation and has application in the treatment of diseases including diabetes mellitus, Raynaud’s disease, angina pectoris and atherosclerosis. Chromatography was carried out on a Phenomenex C18 (250 x 4.6mm, 5μm) column with a mobile phase of 10mM ammonium acetate and acetonitrile (45:55% v/v). The flow rate was 1.2mL/min. The detection wavelength was carried out at 220nm. The retention time is 3.356 minutes for sarpogrelate hydrochloride. The linearity was found in the range of 10-50 μg/ml (R = 0.999) and % RSD is less than 2%. The mean recoveries obtained for sarpogrelate hydrochloride were in the range of 98.73-100.67%. The method is validated as per ICH guidelines and can be applied for the estimation of percentage purity in Sarpogrelate hydrochloride for quality control analysis in bulk and its dosage forms.


2020 ◽  
Vol 10 (4) ◽  
pp. 97-101
Author(s):  
Mithun Rudrapal ◽  
Nazim Hussain

A simple, precise and accurate RP-HPLC method was developed and validated for the estimation of gemifloxacin in the tablet dosage form. The separation was achieved on a reversed-phase C-18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase consisting of acetonitrile/acetate buffer of pH 4.5 (70:30 v/v) at a flow rate of 1.0 ml/min and a detection wavelength of 244 nm. The separation was carried out on an isocratic mode at room temperature. The method was validated as per ICH guidelines for linearity, accuracy, precision, robustness, LOD, LOQ and specificity. The developed method showed good linearity over the concentration range of 50-150 µg/ml (r2=0.995). The average percentage recovery was 99.77%. The LOD and LOQ were 12.678 µg/ml and 14.261 µg/ml, respectively. Based upon validation studies, the developed method can be successfully applied for the routine analysis of gemifloxacin in bulk drugs as well as pharmaceutical dosage forms. Keywords: Gemifloxacin, Tablet dosage form, RP-HPLC, Validation, ICH guidelines


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0244951
Author(s):  
Hany W. Darwish ◽  
Nesma A. Ali ◽  
Ibrahim A. Naguib ◽  
Mohamed R. El Ghobashy ◽  
Abdullah M. Al-Hossaini ◽  
...  

A reliable, selective and sensitive stability-indicating RP-HPLC assay was established for the quantitation of bromazepam (BMZ) and one of the degradant and stated potential impurities; 2-(2-amino-5-bromobenzoyl) pyridine (ABP). The assay was accomplished on a C18 column (250 mm × 4.6 mm i.d., 5 μm particle size), and utilizing methanol-water (70: 30, v/v) as the mobile phase, at a flow rate of 1.0 ml min-1. HPLC detection of elute was obtained by a photodiode array detector (DAD) which was set at 230 nm. ICH guidelines were adhered for validation of proposed method regarding specificity, sensitivity, precision, linearity, accuracy, system suitability and robustness. Calibration curves of BMZ and ABP were created in the range of 1–16 μg mL-1 with mean recovery percentage of 100.02 ± 1.245 and 99.74 ± 1.124, and detection limit of 0.20 μg mL-1 and 0.24 μg mL-1 respectively. BMZ stability was inspected under various ICH forced degradation conditions and it was found to be easily degraded in acidic and alkaline conditions. The results revealed the suitability of the described methodology for the quantitation of the impurity (ABP) in a BMZ pure sample. The determination of BMZ in pharmaceutical dosage forms was conducted with the described method and showed mean percentage recovery of 99.39 ± 1.401 and 98.72 ± 1.795 (n = 6), respectively. When comparing the described procedure to a reference HPLC method statistically, no significant differences between the two methods in regard to both accuracy and precision were found.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Shilpi Pathak ◽  
Pradeep Mishra

Abstract Background A stability-indicating RP-HPLC method was developed and validated for the estimation of empagliflozin drug and its tablet dosage form using a DAD detector. The mobile phase consisted of methanol/acetonitrile/0.1%OPA (75:20:5). The peak was observed at 2.54 min using 222.0 nm absorption maxima. Results Calibration curve plot was found within the range of 10–50 µg/mL. The coefficient of determination (R2) was found to be 0.9990. Forced degradation studies were performed for the empagliflozin in various conditions, and the results were calculated as %RSD values and were found to be within the limits. Conclusion The method was validated as per ICH guidelines with respect to all validation parameters.


Author(s):  
S. Lakshmana Prabu ◽  
S Thiyagarajan ◽  
P Balan ◽  
T N K Suriyaprakash ◽  
Sharavanan S P

A simple, economic, selective, precise, rapid and reproducible stability indicating HPLC method for the analysis of coumarin (CMN) in bulk drugs and from pharmaceutical formulation has been developed and validated. Separation was achieved on a symmetry C18 column using a mobile phase consisting of a mixture of methanol:water in the ratio of (70:30%v/v) at a flow rate of 1ml/min with detection at 276 nm. Linear regression analysis data for the calibration revealed a good linear relationship between response and concentration in the range 2 μgml-1 to 14 μg ml1 of CMN; the correlation coefficient was 0.999. The LOD and LOQ were 30 and 100 ng ml-1 respectively. The method was validated for accuracy, precision, recovery, reproducibility, specificity, robustness and degradation studies. The statistical analysis showed the method to be precise, reproducible, selective, specific and accurate for analysis and estimation of coumarin in bulk drugs and pharmaceutical dosage forms. 


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (07) ◽  
pp. 47-51
Author(s):  
B. Anupama ◽  
P. Tejaswi ◽  
KNV. Chenchu Lakshmi ◽  
A. Vishwanadh

A rapid, simple and precise reversed phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of edoxabantosylate in tablets. The quantification was carried out using a Phenomenex C-18 column (250×4.6 mm i.d., 5µm particle size) in isocratic mode with mobile phase comprising of ammonium acetate buffer andacetonitrile in the ratio of 50:50 (V/V) at a flow rate 1 mL/min. The eluent was monitored at 240 nm. The retention time of the drug was 3.486 min. The calibration curve was linear in the concentration range of 5-25 µg/mL and per cent recovery ranged from 98.25-101.6.The developed method was validated as per ICH guidelines and the results obtained were satisfactory.The method can be applied for routine quality control analysis of edoxabantosylate in tablet dosage forms.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (07) ◽  
pp. 18-22
Author(s):  
D. Gowrisankar ◽  
◽  
N.M Rao

An improved stability-indicating RP-HPLC method was developed for the estimation of troxipide in bulk and tablet dosage forms. Chromatographic separation of troxipide from its degradation products was achieved on Agilent Zorbax SB-CN (150 × 4.6 mm, 3.5 μm) using sodium phosphate buffer (pH was adjusted to 4.0 ±0.05) and acetonitrile in the ratio of 40:60 V/V, at a flow rate of 0.8 mL/min. This system was found to give compact peak for troxipide at 2.1±0.2 min. The detection was monitored at 260 nm. The linear regression data for the calibration plots showed good relationship with r2 = 0.99 ± 0.001. The method was validated for precision, linearity, accuracy and robustness according to International Conference on Harmonization (ICH) guidelines. The percentage RSD was found to be less than two, indicating high degree of accuracy and precision of the proposed RP-HPLC method. The drug was subjected to stress degradation studies under acidic, basic, oxidative and thermal conditions. The degradation studies reveal that purity angle was less than the purity threshold, so the peak was said to be pure. It means that products resulting from stress studies did not interfere with the detection of troxipide and the assay can thus be considered as stability-indicating. Due to its simplicity, rapidness, high precision and accuracy, the proposed HPLC method may be used for determining troxipide in bulk and in pharmaceutical dosage forms.


Sign in / Sign up

Export Citation Format

Share Document