Predicted Ductility Demands for Steel Moment Resisting Frames

1989 ◽  
Vol 5 (2) ◽  
pp. 409-427 ◽  
Author(s):  
Charles W. Roeder ◽  
James E. Carpenter ◽  
Hidetake Taniguchi

Recent changes to the United States seismic design provisions permit the use of weak column-strong beam steel moment resisting frames. This design concept has not been used in the past, because it results in plastic hinges in the columns during moderate or extreme earthquakes. This paper shows the results of inelastic dynamic response calculations on a weak column frame and a comparable strong column system. The results show that the ductility demand is much greater for the weak column strong beam framing system with some acceleration records. The required ductility is then compared for the different structural systems and both are compared to the results of experiments. The comparison suggests that the weak column system may not be able to develop the required ductility. The results of this paper should help define the viability and limits in applicability of the weak column system.

2000 ◽  
Vol 16 (1) ◽  
pp. 205-225 ◽  
Author(s):  
Guy J. P. Nordenson ◽  
Glenn R. Bell

The need for earthquake-resistant construction in areas of low-to-moderate seismicity has been recognized through the adoption of code requirements in the United States and other countries only in the past quarter century. This is largely a result of improved assessment of seismic hazard and examples of recent moderate earthquakes in regions of both moderate and high seismicity, including the San Fernando (1971), Mexico City (1985), Loma Prieta (1989), and Northridge (1994) earthquakes. In addition, improved understanding and estimates of older earthquakes in the eastern United States such as Cape Ann (1755), La Malbaie, Quebec (1925), and Ossippe, New Hampshire (1940), as well as monitoring of micro-activity in source areas such as La Malbaie, have increased awareness of the earthquake potential in areas of low-to-moderate seismicity. Both the hazard and the risk in moderate seismic zones (MSZs) differ in scale and kind from those of the zones of high seismicity. Earthquake hazards mitigation measures for new and existing construction need to be adapted from those prevailing in regions of high seismicity in recognition of these differences. Site effects are likely to dominate the damage patterns from earthquakes, with some sites suffering no damage not far from others, on soft soil, suffering near collapse. A number of new seismic codes have been developed in the past quarter century in response to these differences, including the New York City (1995) and the Massachusetts State (1975) seismic codes. Over the same period, the national model building codes that apply to most areas of low-to-moderate seismicity in the United States, the Building Officials and Code Administrators (BOCA) Code and the Southern Standard Building Code (SSBC), have incorporated up-to-date seismic provisions. The seismic provisions of these codes have been largely inspired by the National Earthquake Hazard Reduction Program (NEHRP) recommendations. Through adoption of these national codes, many state and local authorities in areas of low-to-moderate seismicity now have reasonably comprehensive seismic design provisions. This paper will review the background and history leading up to the MSZ codes, discuss their content, and propose directions for future development.


2016 ◽  
Vol 21 (3) ◽  
pp. 479-500 ◽  
Author(s):  
David Cassiano ◽  
Mario D'Aniello ◽  
Carlos Rebelo ◽  
Raffaele Landolfo ◽  
Luis S. da Silva

2017 ◽  
Vol 11 (1) ◽  
pp. 420-433 ◽  
Author(s):  
David Cassiano ◽  
Carlos Rebelo ◽  
Luís Simoes da Silva

Nowadays, many buildings with steel Moment Resisting Frames (MRF) are built in seismic zones when seismic codes are at its early stages of development, and as such, these structures are often designed solely to resist lateral wind loads without providing an overall ductile mechanism. On the other hand, current seismic design criteria based on hierarchy of resistance allow enhancing the structural ductility and controlling the structural plastic behaviour. Therefore, seismic design criteria might also be beneficial to improve the structural robustness. In order to investigate this issue for steel MRF, a parametric study based on pushdown analysis and on the Energy Balance Method is described and discussed in the present paper. With this regard, the following cases are examined: (i) MRF not designed for seismic actions and (ii) MRF designed for seismic actions. The investigated parameters are (i) the number of storeys, (ii) the interstorey height, (iii) the span length, (iv) the building plan layout and (v) the column loss scenario. Results show that the low-rise and long span structures are the most prone to progressive collapse and that the elements in the directly affected zone of the wind designed 8 storey structures respond in the elastic range. Structures designed according to the capacity design principles were found to be less robust than wind designed structures that are characterized by strong beams and weak columns. The number of elements above the removed column and size of beam cross section were found to be key parameters in arresting progressive collapse.


Sign in / Sign up

Export Citation Format

Share Document