endurance time
Recently Published Documents


TOTAL DOCUMENTS

328
(FIVE YEARS 42)

H-INDEX

35
(FIVE YEARS 0)



2022 ◽  
Vol 2022 ◽  
pp. 1-14
Author(s):  
Qihui Peng ◽  
Wen-ming Cheng ◽  
Peng Guo ◽  
Hongyu Jia

Assessing the seismic performance of the gantry crane is significant since the structure is more vulnerable to earthquakes with the increase in size and lifting weight capacity. This paper aims to investigate the seismic response of the gantry crane incorporating near-field ground motions using incremental dynamic and endurance time analysis (IDA and ETA) methods. To model the structure accurately, a nonlinear finite element model of the gantry crane considering the viscoelastic effect is developed in the OpenSees platform. Then, the IDA method is also carried out for a comparison with the ETA method. The results of the two methods are consistent with a correlation of 93.9% while the computational demand of the ETA method is much less than those of the IDA method. To study further, both the seismic incident angle and the application of viscous dampers using the Maxwell model are analyzed and discussed in detail. The results show that seismic incident angle has a distinct influence on the maximum seismic displacement and viscous dampers can significantly reduce the seismic demand of the gantry crane. These findings support the seismic design of gantry cranes and evaluate the structural seismic performance efficiently.





Author(s):  
Mohd Mukhtar Alam ◽  
Israr Ahmad ◽  
Yogesh Kumar ◽  
Abdul Samad ◽  
Yogesh Upadhyay ◽  
...  

BACKGROUND: Grip strength is widely accepted as an indicator of maximum hand strength and contraction of active muscles of the hand and forearm. OBJECTIVE: The aim of this study was to assess the effects of forearm posture (pronation, supination and neutral) and anthropometric variation on MVC grip strength and grip endurance time in young university adults. METHODS: Fifty healthy, right-handed men volunteered to participate in this study. The experiment was characterized by measuring MVC grip strength and endurance time of 50% MVC randomly in three different postures (supine, pronation and neutral). Performance was assessed in terms of dependent variables: MVC grip strength and grip endurance time. RESULTS: MANCOVA results showed no significant effect of posture on MVC grip strength ([Formula: see text]) and grip endurance time ([Formula: see text]). There was a significant effect of age ([Formula: see text]), height ([Formula: see text]) and forearm length ([Formula: see text]) on the grip endurance time in supine position. However, palm circumference had a significant effect on MVC grip strength ([Formula: see text]) in pronation posture only. The pronation forearm posture produces 7.4% more grip strength than a supine posture. In addition, the grip endurance time was improved in the supine position, compared to the neutral and pronation forearm posture. CONCLUSIONS: This study showed that the MVC grip strength is affected by the weight and palm circumference. In addition, palm circumference was the most influential factor affecting grip strength. Thus, anthropometric and posture-specific grip strength data are essential for clinical and industrial applications. The results can be used to prepare guidelines for rehabilitation, health care, sport and medicine.



Author(s):  
Angela Boutellier ◽  
Corina Nüesch ◽  
Peter Suter ◽  
Guido Perrot ◽  
Annegret Mündermann

BACKGROUND: The function of trunk muscles in chronic nonspecific low back pain (CNLBP) is controversially discussed, and trunk muscle function in sedentary occupation workers is poorly understood. OBJECTIVE: To investigate whether muscle function differs between sedentary occupation workers with and without CNLBP and to determine the association between functional limitations and muscle function. METHODS: This study included 32 sedentary occupation workers (16 workers with CNLBP and 16 age- and sex-matched workers without CNLBP). Group differences in isokinetic trunk flexion-extension strength, muscle cocontraction, endurance time (Biering-Sorensen test) and electromyographic muscle fatigue were assessed. The association of these parameters and Oswestry Disability Index (ODI) score were examined in the CNLBP group. RESULTS: Participants with CNLBP had lower trunk extensor (-20%) and flexor (-18%) strength and less cocontraction (-22%) than participants without CNLBP, but due to large variability in both groups these differences were not statistically significant. Trunk muscle endurance and fatigue were comparable between groups. Variance in endurance time explained 28% of variance in the ODI-score in the CNLBP group (R2= 0.277). CONCLUSIONS: In patients with CNLBP, greater functional disability was associated with lower endurance. Further evidence is necessary to elucidate whether specifically training endurance performance may be beneficial for sedentary occupation workers.



Thorax ◽  
2021 ◽  
pp. thoraxjnl-2020-216509
Author(s):  
Tessa Schneeberger ◽  
Inga Jarosch ◽  
Daniela Leitl ◽  
Rainer Gloeckl ◽  
Wolfgang Hitzl ◽  
...  

RationaleIn patients with COPD, oxygen (O2)-supplementation via a constant flow oxygen system (CFOS) can result in insufficient oxygen saturation (SpO2 <90%) during exercise. An automatically titrating O2-system (ATOS) has been shown to be beneficial compared with an untitrated CFOS, however, it is unknown if ATOS is superior to CFOS, titrated during exercise as stipulated by guidelines. The aim was to investigate the effects of ATOS compared with titrated CFOS on walking capacity in people with hypoxaemic COPD.MethodsFifty participants completed this prospective randomised controlled, double-blind, crossover trial. Participants performed two endurance shuttle walk tests (ESWTs) with: (1) exercise titrated CFOS (ESWTCFOS) and (2) ATOS targeting an SpO2 of 92% (ESWTATOS). Primary outcome measure was walking time. Secondary measures were SpO2, transcutaneous-PCO2 (TcPCO2), respiratory rate (RR), heart rate (HR) at isotime (end of shortest ESWT) with blood gases and dyspnoea at rest and end exercise.ResultsParticipants (median (IQR): age 66 (59, 70) years, FEV1 28.8 (24.8, 35.1) % predicted, PO2 54.7 (51.0, 57.7) mm Hg, PCO2 44.2 (38.2, 47.8) mm Hg) walked significantly longer with ESWTATOS in comparison to ESWTCFOS (median effect (95% CI) +144.5 (54 to 241.5) s, p<0.001). At isotime, SpO2 was significantly higher (+3 (95% CI 1 to 4) %, p<0.001) with ATOS while TcPCO2, RR and HR were comparable. End exercise, PO2 (+8.85 (95% CI 6.35 to 11.9) mm Hg) and dyspnoea (−0.5 (95% CI −1.0 to −0.5) points) differed significantly in favour of ATOS (each p<0.001) while PCO2 was comparable.ConclusionIn patients with hypoxaemia with severe COPD the use of ATOS leads to significant, clinically relevant improvements in walking endurance time, SpO2, PO2 and dyspnoea with no impact on PCO2.Trial registration numberNCT03803384.



2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sophia Gutweniger ◽  
Tsogyal D. Latshang ◽  
Sayaka S. Aeschbacher ◽  
Fabienne Huber ◽  
Deborah Flueck ◽  
...  

AbstractThis trial evaluates whether nocturnal oxygen therapy (NOT) during a stay at 2048 m improves altitude-induced exercise intolerance in lowlanders with chronic obstructive pulmonary disease (COPD). 32 lowlanders with moderate to severe COPD, mean ± SD forced expiratory volume in the first second of expiration (FEV1) 54 ± 13% predicted, stayed for 2 days at 2048 m twice, once with NOT, once with placebo according to a randomized, crossover trial with a 2-week washout period at < 800 m in-between. Semi-supine, constant-load cycle exercise to exhaustion at 60% of maximal work-rate was performed at 490 m and after the first night at 2048 m. Endurance time was the primary outcome. Additional outcomes were cerebral tissue oxygenation (CTO), arterial blood gases and breath-by-breath measurements (http://www.ClinicalTrials.gov NCT02150590). Mean ± SE endurance time at 490 m was 602 ± 65 s, at 2048 m after placebo 345 ± 62 s and at 2048 m after NOT 293 ± 60 s, respectively (P < 0.001 vs. 490 m). Mean difference (95%CI) NOT versus placebo was − 52 s (− 174 to 70), P = 0.401. End-exercise pulse oximetry (SpO2), CTO and minute ventilation ($${\dot{\text{V}}}_{{\text{E}}}$$ V ˙ E ) at 490 m were: SpO2 92 ± 1%, CTO 65 ± 1%, $${\dot{\text{V}}}_{{\text{E}}}$$ V ˙ E 37.7 ± 2.0 L/min; at 2048 m with placebo: SpO2 85 ± 1%, CTO 61 ± 1%, $${\dot{\text{V}}}_{{\text{E}}}$$ V ˙ E  40.6 ± 2.0 L/min and with NOT: SpO2 84 ± 1%; CTO 61 ± 1%; $${\dot{\text{V}}}_{{\text{E}}}$$ V ˙ E  40.6 ± 2.0 L/min (P < 0.05, SpO2, CTO at 2048 m with placebo vs. 490 m; P = NS, NOT vs. placebo). Altitude-related hypoxemia and cerebral hypoxia impaired exercise endurance in patients with moderate to severe COPD and were not prevented by NOT.



Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6577
Author(s):  
Dongli Tan ◽  
Guicheng Ran ◽  
Guangling Xie ◽  
Jie Wang ◽  
Jianbin Luo ◽  
...  

With the improvement and development of micro-mechanical manufacturing technology, people can produce an increasing variety of micro-electromechanical systems in recent years, such as micro-satellite thrusters, micro-sensors, micro-aircrafts, micro-medical devices, micro-pumps, and micro-motors. At present, these micro-mechatronic systems are driven by traditional energy power systems, but these traditional energy power systems have such disadvantages as short endurance time, large size, and low energy density. Therefore, efforts were made to study micro-energy dynamical systems with small size, light gravity, high density and energy, and long duration so as to provide continuous and reliable power for these systems. In general, the micro-thermal photoelectric system not only has a simple structure, but also no moving parts. The micro-thermal photoelectric system is a micro-energy power system with good application prospects at present. However, as one of the most important structural components of micro-thermal photoelectric systems, the microburner, is the key to realize the conversion of fuel chemical energy to electric energy in micro-thermal photoelectric system. The studies of how to improve the flame stability and combustion efficiency are very necessary and interesting. Thus, some methods to improve the performance of micro-burners were introduced and summarized systematically, hoping to bring some convenience to researchers in the field.



Sign in / Sign up

Export Citation Format

Share Document