Performance Evaluation of Passive Damping Systems for the Seismic Retrofit of Steel Moment-Resisting Frames Subjected to Near-Field Ground Motions

2001 ◽  
Vol 17 (3) ◽  
pp. 427-456 ◽  
Author(s):  
André Filiatrault ◽  
Robert Tremblay ◽  
Assawin Wanitkorkul

Passive friction and viscous damping systems for retrofitting steel moment-resisting frames located along the west coast of the United States are considered. First, preliminary design procedures are presented for friction as well as linear and nonlinear viscous damping systems. Thereafter, nonlinear dynamic analyses are performed on a six-story moment-resisting frame designed according to seismic provisions for California prior to the 1994 Northridge earthquake. A flexural strength degradation model is considered to account for the brittle behavior of pre-Northridge welded beam-to-column connections. The structure was subjected to three different earthquake ensembles including near-field records developed for major crustal earthquakes in California. The results of a parametric study indicate that, although both friction and viscous damping systems reduce significantly the response of the structure, they are unable by themselves to prevent fracture of welded beam-to-column joints. Connection retrofit measures of the types elaborated after the Northridge earthquake would still be required.

1989 ◽  
Vol 5 (2) ◽  
pp. 409-427 ◽  
Author(s):  
Charles W. Roeder ◽  
James E. Carpenter ◽  
Hidetake Taniguchi

Recent changes to the United States seismic design provisions permit the use of weak column-strong beam steel moment resisting frames. This design concept has not been used in the past, because it results in plastic hinges in the columns during moderate or extreme earthquakes. This paper shows the results of inelastic dynamic response calculations on a weak column frame and a comparable strong column system. The results show that the ductility demand is much greater for the weak column strong beam framing system with some acceleration records. The required ductility is then compared for the different structural systems and both are compared to the results of experiments. The comparison suggests that the weak column system may not be able to develop the required ductility. The results of this paper should help define the viability and limits in applicability of the weak column system.


Structures ◽  
2021 ◽  
Vol 32 ◽  
pp. 1646-1664
Author(s):  
Elena Elettore ◽  
Annarosa Lettieri ◽  
Fabio Freddi ◽  
Massimo Latour ◽  
Gianvittorio Rizzano

2021 ◽  
Vol 244 ◽  
pp. 112751
Author(s):  
Carlos Molina Hutt ◽  
Shervin Zahedimazandarani ◽  
Nasser A. Marafi ◽  
Jeffrey W. Berman ◽  
Marc O. Eberhard

Sign in / Sign up

Export Citation Format

Share Document