High-intensity focused ultrasound ablation for treatment of chemotherapy-induced thrombocytopenia and hypersplenism.

2021 ◽  
Vol 39 (15_suppl) ◽  
pp. 3082-3082
Author(s):  
Min Yuan ◽  
Qing Xu ◽  
Zhongzheng Zhu ◽  
Wei Mao ◽  
Xianling Guo ◽  
...  

3082 Background: Chemotherapy-induced thrombocytopenia (CIT) contributes to treatment dose delay and/or modification, often resulting in poorer survival and disease progression. Compared with partial splenic embolization (PSE) and drugs, high-intensity focused ultrasound has the advantages as following: (1) it is a noninvasive treatment modality with potentially fewer adverse effects and complications; (2) the hospital stay and recovery time after treatment are short; (3) its cost is relatively low compared to surgery. The purpose of this work was to preliminarily investigate the efficacy and safety of high intensity focused ultrasound treatment of chemotherapy-induced thrombocytopenia (CIT) and hypersplenism. Methods: 26 patients with chemotherapy-induced thrombocytopenia and hypersplenism (15 male and 11 female; median age, 56 years; range, 51-66 years) were treated with ultrasound guided high-intensity focused ultrasound. Complications were recorded. Laboratory examination and magnetic resonance imaging were used to evaluate the efficacy. The spleen volume and ablation volume rate of the spleen were calculated by MRI after treatment. They were followed closely for at least 6 months. Results: After high-intensity focused ultrasound treatment, the MRI showed that the ablation area had turned into a non-perfused volume, the mean percent spleen ablation volume was 18.76% ± 6.1% (range, 11.17%-32.34%). After 6 months of HIFU ablation, the ablated area shrank evidently; the sunken spleen formed a lobulated shape and the splenic volume decreased. The platelet count increased 3-7 days after treatment and remained for 1-2weeks higher than baseline (53.33 ± 15.80 × 109/L). The white blood cell count and platelet count of the patients were substantially improved during the follow-up period. No substantial difference was observed in RBC counts between baseline and after treatment. In addition, symptoms such as epistaxis and gingival bleeding were ameliorated or even eliminated, and the quality of life was improved. Follow-up imaging showed a nonperfused volume in the spleen. Conclusions: For the first time to our knowledge, high-intensity focused ultrasound ablation was used to treat Chemotherapy-induced thrombocytopenia (CIT) and hypersplenism. High-intensity focused ultrasound ablation of the spleen may cause damage to a certain volume of the spleen parenchyma to achieve the purpose of hypersplenism treatment. High intensity focused ultrasound may be an effective and safe alternative for treatment of CIT and hypersplenism.

2019 ◽  
Vol 1 (4) ◽  
pp. 316-323 ◽  
Author(s):  
David R Brenin ◽  
James Patrie ◽  
Jonathan Nguyen ◽  
Carrie M Rochman

Abstract Objective Breast fibroadenomas (FAs) are common, benign, and often bothersome. Current management includes observation or surgical excision. This study evaluated the safety and feasibility of ultrasound-guided high-intensity focused ultrasound ablation for the treatment of FAs. Methods Twenty women with a palpable, biopsy-confirmed FA were enrolled in a prospective trial, and they underwent treatment utilizing an ultrasound-guided high-intensity focused ultrasound ablation device. Tumors were greater than 1 cm in diameter, with volumes of 0.3–10 cc. Safety, treatment experience, toxicity, cosmesis, and change in tumor size on palpation and ultrasound measurement were obtained before and after treatment at 3, 6, and 12 months. Results All of the 20 patients completed therapy. Pretreatment mean tumor volume was 1.8 cc (standard deviation = 1.23, range 0.57–5.7). Half of the patients reported a painful mass before treatment. All adverse events were well tolerated and transient, with the most common being mild pain, reported by 15 of 20 patients during treatment, and 14 of 20 at the day-7 postprocedure follow-up. Mean pain score during treatment was 16, and at day 7, it was 12.2, on a scale from 0 to 100 (100 = worst pain). Mean patient satisfaction was 4.4 on a scale of 1–5 (5 = most satisfied). Mean likelihood of recommending treatment was 4.7 (5 = most likely). At the 12-month postprocedure follow-up, the mean reduction in volume of the FA was 65.5% on ultrasound; the mass was no longer palpable in 80% of the patients; no patients reported pain; and cosmesis was rated as excellent in all patients. Conclusion Ultrasound-guided high-intensity focused ultrasound ablation appears to be effective, safe, and well tolerated for the treatment of FAs. A larger multicenter clinical trial is currently under way.


2010 ◽  
Vol 37 (6Part1) ◽  
pp. 2533-2540 ◽  
Author(s):  
Bruno Quesson ◽  
Mathilde Merle ◽  
Max O. Köhler ◽  
Charles Mougenot ◽  
Sebastien Roujol ◽  
...  

2017 ◽  
Vol 6 (18) ◽  
pp. 1700514 ◽  
Author(s):  
Adem Yildirim ◽  
Rajarshi Chattaraj ◽  
Nicholas T. Blum ◽  
Dennis Shi ◽  
Kaushlendra Kumar ◽  
...  