Suture Material

Author(s):  
John J. Bogdanske ◽  
Scott Hubbard-Van Stelle ◽  
Margaret Rankin Riley Riley ◽  
Beth M. Schiffman
Keyword(s):  
VASA ◽  
2015 ◽  
Vol 44 (6) ◽  
pp. 451-457 ◽  
Author(s):  
Vincenzo Gasbarro ◽  
Luca Traina ◽  
Francesco Mascoli ◽  
Vincenzo Coscia ◽  
Gianluca Buffone ◽  
...  

Abstract. Background: Absorbable sutures are not generally accepted by most vascular surgeons for the fear of breakage of the suture line and the risk of aneurysmal formation, except in cases of paediatric surgery or in case of infections. Aim of this study is to provide evidence of safety and efficacy of the use of absorbable suture materials in carotid surgery. Patients and methods: In an 11 year period, 1126 patients (659 male [58.5 %], 467 female [41.5 %], median age 72) underwent carotid endarterectomy for carotid stenosis by either conventional with primary closure (cCEA) or eversion (eCEA) techniques. Patients were randomised into two groups according to the type of suture material used. In Group A, absorbable suture material (polyglycolic acid) was used and in Group B non-absorbable suture material (polypropylene) was used. Primary end-point was to compare severe restenosis and aneurysmal formation rates between the two groups of patients. For statistical analysis only cases with a minimum period of follow-up of 12 months were considered. Results: A total of 868 surgical procedures were considered for data analysis. Median follow-up was 6 years (range 1-10 years). The rate of postoperative complications was better for group A for both cCEA and eCEA procedures: 3.5 % and 2.0 % for group A, respectively, and 11.8 % and 12.9 % for group B, respectively. Conclusions: In carotid surgery, the use of absorbable suture material seems to be safe and effective and with a general lower complications rate compared to the use of non-absorbable materials.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
B Hughes ◽  
J Stallard ◽  
S Jivan

Abstract Introduction Surgical drains are used by many specialities, we aim to determine the most robust method of securing them by comparing suturing technique, material and fixation angle. Method A Blake’s drain was inserted into a piece of pork belly and secured using a standard ‘three half hitch’ technique with 3.0 Silk, EthilonTM and ProleneTM . For each suture type, drains were sutured in line, at 45 and 90 degrees to the course of the drain. The force needed for the suture to failure was measured and each repeated 3 times. Different suture techniques were then used to determine the strongest fixation. Results With the drain exiting inline the moment of failure was, on average, 1.25kg for silk, 3.5kg for EthilonTM and 4.0kg for ProleneTM. Increasing drain fixation angle required more force for the suture to fail. With EthilonTM and ProleneTM, the suture snapped before the drain slipped. Three half hitches was the strongest technique. Conclusions Suture material, technique and drain fixation angle had an impact on suture strength with ProleneTM outperforming Silk. We advocate using a ‘three half hitch’ technique with 3.0 ProleneTM to secure a surgical drain. It offers superior strength whilst reducing the risk of localised tissue reactions.


2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Hikaru Watanabe ◽  
Kohei Abe ◽  
Naoki Kanauchi

Abstract Background It is uncommon for a bronchial stump-related complication to develop during the remote postoperative period in a case of obstructive pneumonia owing to migration of the suture material. Here, we describe a case of bronchial obstructive pneumonia that developed owing to migration of the suture material in the airway 8 years after pulmonary resection. Case presentation A 34-year-old woman underwent left lower lobectomy for a pulmonary carcinoid tumor (pT1bN0M0-stage IA) in 2010. She experienced obstructive pneumonia, and chest computed tomography revealed a mass protruding from the bronchial stump to the bronchial lumen in 2018. After treatment for pneumonia, flexible bronchoscopy showed the presence of a fibrous suture material (Teflon pledget) completely obstructing the left second carina. A week later, the Teflon pledget obstructing the bronchial lumen was removed using a flexible bronchoscope with the patient under general anesthesia. The procedure was completed without removing the small amount of granulation tissue because the bronchial lumen opened after removing the Teflon pledget. She has remained asymptomatic for 1 year after removal. Conclusions In this case, the complication of obstructive pneumonia developed owing to migration of the non-absorbable suture materials used to suture the bronchial stump. Bronchoscopic management of this rare complication comprised endobronchial removal with the patient under general anesthesia. Given our experience with this case, we believe that such conservative management should allow for excellent results in most instances and avoid the need for reoperation.


2006 ◽  
Vol 39 (01) ◽  
pp. 94-102
Author(s):  
G. Balakrishnan

ABSTRACTStronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively). The technique is well-described and uses preformed looped sutures (supramid). This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.


Sign in / Sign up

Export Citation Format

Share Document