Purging and Sampling Device Selection and Operation

Author(s):  
David Nielsen
Author(s):  
Chris Schuermyer ◽  
Brady Benware ◽  
Graham Rhodes ◽  
Davide Appello ◽  
Vincenzo Tancorre ◽  
...  

Abstract This work presents the first application of a diagnosis driven approach for identifying systematic chain fail defects in order to reduce the time spent in failure analysis. The zonal analysis methodology that is applied separates devices into systematic and random populations of chain fails in order to prevent submitting random defects for failure analysis. Two silicon case studies are presented to validate the production worthiness of diagnosis driven yield analysis for chain fails. The defects uncovered in these case studies are very subtle and would be difficult to identify with any other methodology.


1991 ◽  
Vol 23 (1-3) ◽  
pp. 545-553
Author(s):  
M. Rödelsperger ◽  
U. Rohmann ◽  
F. Frimmel

A sampling device was designed as a stationary equipment for deep monitoring wells in order to obtain representative groundwater samples from different layers of the aquifer. The device consists of several packer units which can be combined at variable distances, allowing adaption to the local conditions of the aquifer and of the well. The pumps are situated below the groundwater table. Each of the drawing tubes ends between two packers at the concerning depth. Experimental results demonstrate the importance of the application of a stationary packer system instead of a mobile doublepacker in deep aquifers of inhomogeneous structure. Examples of concentration profiles obtained from layerwise groundwater sampling are given and a technique for selective groundwater discharge is described.


2020 ◽  
Author(s):  
Andrés Herane-Vives

BACKGROUND “Short-term” samples are not the most appropriate for reflecting Chronic Cortisol Concentration (CCC). Although hair is used for reflecting the systemic cortisol level over “long-term”, its use appears clinically problematic. Local stress and non-stress related factors may release a circumscribed cortisol secretion that is accumulated in hair. Non-stressful earwax extraction methods may provide a more accurate specimen to measure CCC. OBJECTIVE Correlate cortisol levels using hair, serum and earwax samples METHODS Earwax from both ears of 37 controls were extracted using a clinical procedure commonly associated with local pain. One month later, earwax from the left ear side was extracted using the same procedure, and earwax from the right ear side was comfortably extracted, using an earwax self-sampling device. Participants also provided one centimetre of hair that represented the retrospective month of cortisol output, and one serum sample that reflected the effect of systemic stressors on cortisol levels. Earwax (ECC), Hair (HCC) and Serum (SCC) Cortisol Concentration were correlated and compared. Confounders´ effect on cortisol levels were studied. RESULTS Serum showed the largest and hair the lowest cortisol concentration (p<0.01). Left-ECC was larger than Right-ECC (p=0.03). Right-ECC was the only sample unaffected by confounders (all p>0.05). Right-ECC and HCC showed the only significant association (r=0.39; p=0.03). CONCLUSIONS The self-sampling device did not represent a local stressor for the ceruminous glands. It provided the cortisol level with the least likely to be affected by confounding factors over the previous month. ECC using the novel device may constitute another accurate, but more suitable and affordable specimen for measuring CCC.


2021 ◽  
Vol 13 (1) ◽  
pp. 1920226
Author(s):  
Monique Melo Costa ◽  
Nicolas Benoit ◽  
Jerome Dormoi ◽  
Remy Amalvict ◽  
Nicolas Gomez ◽  
...  
Keyword(s):  

Author(s):  
Malay S. Patel ◽  
Matthew D. Carson ◽  
Eric J. Seibel ◽  
Lucas R. Meza

Author(s):  
Enrique Garcia‐Sayan ◽  
Deepa Raghunathan ◽  
Flora M. Li ◽  
Abhijeet Dhoble ◽  
Richard D. Sheu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document